Free-hanging vertical run
Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−
Product
RT 113 / RT 123 300/500 V (UL/CSA 600 V) Class 6 TMPU PUR High-Torsion (±450°/0.5m) Wind Pitch Control Cable (DIN VDE 0285 / UL 600V) engineered for 300/500 V (UL 600 V) wind turbine service across -50 to +90 °C (min. bend radius 5 × OD).
Typical values for this cable type, based on DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification — confirmed in the datasheet and quotation for your order.
Application fit
RT 113 / RT 123 300/500 V (UL/CSA 600 V) Class 6 TMPU PUR High-Torsion (±450°/0.5m) Wind Pitch Control Cable (DIN VDE 0285 / UL 600V) engineered for 300/500 V (UL 600 V) wind turbine service across -50 to +90 °C (min. bend radius 5 × OD).
Class 5, Class 6 and Class K extra-flexible copper cores withstand continuous ±150°/m drip-loop and ±450°/0.5m pitch torsion down to −40/−
UL 2277 WTTC 1,000 V / UL 1277 TC-ER 600 V and IEC 0.6/1 kV ratings allow open tray and Exposed Run routing across the nacelle and tower.
Number-coded cores and 85% tinned copper braid / foil+braid shields terminate neatly into pitch servo boxes, slip-rings and PLC cabinets.
PUR-sheathed Class 6 pitch & slip-ring cables (RT 113/123, RT 114/116) handle combined rotary hub motion and bending.
Wind turbine control and tray cable is not engineered for deepwater vertical oceanographic lift winches.
Use A304739 BOP MUX UmbilicalConstruction
Shown: RT 113 / RT 123 PUR Pitch Control (DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification) featuring class 6 ultra-fine bare copper (2-25 cores), special tpe low-temperature core insulation and tmpu halogen-free pur outer sheath (-50 °c) (4-layer construction).
| # | Layer | Material & reference |
|---|---|---|
| 1 | Class 6 Ultra-Fine Bare Copper (2-25 Cor | IEC 60228 Class 6 extra-fine copper strands (0.25–2.5 mm²) |
| 2 | Special TPE Low-Temperature Core Insulat | Thermoplastic elastomer insulation remaining supple at -50 °C |
| 3 | Low-Friction Wrap & Screen (RT 113 / RT | Unscreened (RT 113) or tinned copper screen (RT 123) for ±450°/0.5m torsion |
| 4 | TMPU Halogen-Free PUR Outer Sheath (-50 | Oil-, microbe- and abrasion-resistant polyurethane jacket |
Built to DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification with class 6 ultra-fine bare copper (2-25 cores) and tmpu halogen-free pur outer sheath (-50 °c)
Available on bulk export reels or pre-cut to turbine tower section and nacelle drip-loop lengths
Supplied with EN 10204 3.1 routine dielectric, conductor DC resistance & cold-torsion qualification report
Technical data
Sizes
Manufactured to DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification for wind turbine yaw drip-loop, pitch control, tower power and converter applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| RT 113 / RT 123 PUR Pitch Control Construction Schedule (−50…+90 °C) | |||||||
| RT 113 7G1.5 mm² | 7G1.5 mm² (or 7C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 11.4 | 215 | 2.4 | 70 | |
| RT 113 12G1.5 mm² | 12G1.5 mm² (or 12C × 16 AWG) | IEC 60228 Class 5/6 / Class K Cu | 14.8 | 345 | 4.1 | 90 | |
| RT 113 18G2.5 mm² | 18G2.5 mm² (or 18C × 14 AWG) | IEC 60228 Class 5/6 / Class K Cu | 19.6 | 680 | 9.8 | 120 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance | Operating temp. |
|---|---|---|---|
| 7G1.5 mm² (or 7C × 16 AWG) | 13.30 | 300/500 V (UL 600 V) (18 A) | −50…+90 °C |
| 12G1.5 mm² (or 12C × 16 AWG) | 13.30 | 300/500 V (UL 600 V) (16 A) | −50…+90 °C |
| 18G2.5 mm² (or 18C × 14 AWG) | 7.98 | 300/500 V (UL 600 V) (24 A) | −50…+90 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance & dimensional verification (DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification) | DC resistance at 20 °C and insulation/sheath wall thickness within DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification) | Zero dielectric breakdown and verified insulation resistance for 300/500 V (UL 600 V) rating | Every manufactured drum length |
| Sample tests | ||
| Low-temperature drip-loop torsion, oil & flame qualification (DIN VDE 0285 & UL/CSA 600 V RT 113 (Unscreened) / RT 123 (Screened) ±450°/0.5m Pitch Specification) | Verified cold torsion cycle endurance, oil resistance and flame retardancy across −50…+90 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ