Contact

NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon CableNF M 87-202 / IEC 60332-3 · 500 V · -30 °C to +70 °C industrial EGPF construction

NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon Instrument Cable (EGPF) engineered to NF M 87-202 / IEC 60332-3 for 500 V service across -30 °C to +70 °C, featuring stranded stranded copper conductor and pvc outer sheath with minimum bending

Approved
Low-EMC design
EMC screen
Oil-resistant
Order designation
EGPF 4×2×1.0
Outer Ø ≈
13.5 mm
Total weight ≈
264 kg/km
Min. bend R (fixed)
108 mm
Configuration
4×2×1.0 mm²
All sizes (12)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
500 V
Per NF M 87-202 / IEC 60332-3
Operating temp.
−30…+70 °C
Continuous thermal rating
Min. bend radius
12 × OD
Installed / fixed routing
Conductor
stranded copper
High-conductivity stranded copper
Outer layer
PVC outer sheath
Extruded PVC outer sheath protective
Standard
NF M 87-202
NF M 87-202 / IEC 60332-3

Typical values for this cable type, based on NF M 87-202 / IEC 60332-3 — confirmed in the datasheet and quotation for your order.

Application fit

Is EGPF right for your machine?

NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon Instrument Cable (EGPF) engineered to NF M 87-202 / IEC 60332-3 for 500 V service across -30 °C to +70 °C, featuring stranded stranded copper conductor and pvc outer sheath with minimum bending

Fixed installation

Suitable

Engineered and verified for fixed service in accordance with NF M 87-202 / IEC 60332-3.

Switchgear & control cabinet wiring

Suitable

Suitable for switchgear, control panels and equipment terminations within 12 × OD bend radius.

TBM gantry & advancing tunnel reel

With conditions

Use mechanical conduit or armoured protection where exposed to rock fall or crushing loads.

Motorised monospiral reel

Not suitable

Not designed for high-speed monospiral crane reeling; select a dedicated reeling cable.

NSHTOU Reeling Cable
Typical machinesOil & Gas CableRefinery & Petrochemical Process UnitsLNG Terminals & Tank FarmsOnshore & Offshore Oil & Gas FacilitiesChemical & Hydrocarbon Processing Plants

Construction

Layer by layer

Shown: EGPF (NF M 87-202 / IEC 60332-3) with stranded stranded copper conductor, pvc core insulation and pvc outer sheath (9-layer construction).

123456789
Schematic, not to scale — generated from the layer data
#LayerMaterial & reference
1Stranded stranded copper conductorHigh-conductivity stranded copper conductor per NF M 87-202 / IEC 60332-3NF M 87-202 / IEC 60332-3
2PVC core insulationExtruded PVC dielectric (individual core / group layer)NF M 87-202 / IEC 60332-3
3Plastic binder tapeHelically applied plastic binder tapeNF M 87-202 / IEC 60332-3
4Al/PET overall screenAl/PET overall screen metallic electromagnetic screen (lapped tape)NF M 87-202 / IEC 60332-3
5PVC inner sheathExtruded PVC inner sheath protective layer (continuous layer)NF M 87-202 / IEC 60332-3
6Lead moisture barrierExtruded Lead moisture barrier protective layer (continuous layer)NF M 87-202 / IEC 60332-3
7Inner steel armour tapeInner steel armour tape mechanical protection (lapped tape)NF M 87-202 / IEC 60332-3
8Outer steel armour tapeOuter steel armour tape mechanical protection (lapped tape)NF M 87-202 / IEC 60332-3
9PVC outer sheathExtruded PVC outer sheath protective layer (continuous layer)NF M 87-202 / IEC 60332-3

EGPF — Standard Execution

Built to NF M 87-202 / IEC 60332-3 with stranded stranded copper conductor and pvc outer sheath

EGPF — Custom Cross-Sections

Full range of metric mm² and AWG/kcmil conductor sizes per NF M 87-202 / IEC 60332-3

EGPF — Export Drum Supply

Supplied with EN 10204 3.1 routine dielectric & conductor resistance test certificate

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on NF M 87-202 / IEC 60332-3. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / duty
500 V (NF M 87-202 / IEC 60332-3)
Conductor construction
Stranded stranded copper conductor — High-conductivity stranded copper conductor per NF M 87-202 / IEC 60332-3
Primary insulation / dielectric
PVC core insulation — Extruded PVC dielectric (individual core / group layer)

Thermal

Continuous operating temperature
−30…+70 °C per NF M 87-202 / IEC 60332-3
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s adiabatic limit depending on dielectric class)
Minimum installation temperature
−5 °C (thermoplastic) / −25 °C (cross-linked or elastomer) / −40 °C (metallic)

Mechanical

Outer protection / covering
PVC outer sheath — Extruded PVC outer sheath protective layer (continuous layer)
Minimum bending radius
12 × OD (installed / static routing)
Layer count & geometry
9 concentric/structural layers verified by cross-section inspection

Resistance

Environmental & chemical durability
Engineered for industrial service in accordance with NF M 87-202 / IEC 60332-3
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing product standard
NF M 87-202 / IEC 60332-3
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
EGPF
Customs tariff (HS)
8544.49 / 8544.60 / 7614.10

Sizes

12 standard EGPF cable configurations

Manufactured to NF M 87-202 / IEC 60332-3 in single-pair, multi-pair and multi-unit constructions.

Dimensions, construction & weights
Order designationConfigurationOuter Ø ≈
mm
Weight ≈
kg/km
Min. bend R
fixed mm
Enquiry
EGPF Standard Construction Schedule (500 V · −30…+70 °C)
EGPF 1×2×0.51×2×0.5 mm²6.45852
EGPF 2×2×0.52×2×0.5 mm²9.211274
EGPF 4×2×0.54×2×0.5 mm²11.417692
EGPF 8×2×0.58×2×0.5 mm²14.8295118
EGPF 12×2×0.512×2×0.5 mm²17.6420141
EGPF 1×2×1.01×2×1.0 mm²7.68661
EGPF 2×2×1.02×2×1.0 mm²11.016888
EGPF 4×2×1.04×2×1.0 mm²13.5264108
EGPF 8×2×1.08×2×1.0 mm²17.9465143
EGPF 1×2×1.51×2×1.5 mm²8.511468
EGPF 4×2×1.54×2×1.5 mm²15.2348122
EGPF 12×2×1.512×2×1.5 mm²23.4860187
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Additional pair/triad/quad counts (up to 48 pairs) and blue Ex-i intrinsically safe outer sheaths available per NF M 87-202 / IEC 60332-3.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance & dimensional verification (NF M 87-202 / IEC 60332-3)DC resistance at 20 °C and geometry within NF M 87-202 / IEC 60332-3 class limitsEvery manufactured drum / spool
Routine dielectric / spark / structural integrity test (NF M 87-202 / IEC 60332-3)Zero breakdown or structural defect over full production lengthEvery manufactured drum / spool
Sample tests
Thermal aging, mechanical & material qualification (NF M 87-202 / IEC 60332-3)Full compliance with NF M 87-202 / IEC 60332-3 across −30…+70 °CType qualification & periodic sample audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

NF M 87-202 CompliantEN 10204 3.1 Routine Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX EGPF <size> NF M 87-202 500 V CE
Delivery form
Non-returnable fumigated wooden drums or precision DIN spools
Standard lengths
500 m · 1000 m · 2000 m drums (custom cut lengths on request)
MOQ
500 m (stock sizes) · 1000 m (custom production)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-21
Updated
2026-10-21

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define EGPF (NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon Instrument Cable)?
EGPF (NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon Instrument Cable) is manufactured in accordance with NF M 87-202 / IEC 60332-3 for 500 V service over -30 °C to +70 °C. Its 9-layer construction comprises stranded stranded copper conductor, pvc core insulation, plastic binder tape, al/pet overall screen, pvc inner sheath, lead moisture barrier, inner steel armour tape, outer steel armour tape, pvc outer sheath.
What is the minimum bending radius and installation temperature for EGPF?
The minimum installed bending radius for EGPF is 12 × OD across its continuous operating temperature range of -30 °C to +70 °C, ensuring mechanical and dielectric stability without conductor or insulation strain.
How are the concentric layers of EGPF arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Stranded stranded copper conductor (High-conductivity stranded copper conductor per NF M 87-202 / IEC 60332-3); (02) PVC core insulation (Extruded PVC dielectric (individual core / group layer)); (03) Plastic binder tape (Helically applied plastic binder tape); (04) Al/PET overall screen (Al/PET overall screen metallic electromagnetic screen (lapped tape)); (05) PVC inner sheath (Extruded PVC inner sheath protective layer (continuous layer)); (06) Lead moisture barrier (Extruded Lead moisture barrier protective layer (continuous layer)); (07) Inner steel armour tape (Inner steel armour tape mechanical protection (lapped tape)); (08) Outer steel armour tape (Outer steel armour tape mechanical protection (lapped tape)); (09) PVC outer sheath (Extruded PVC outer sheath protective layer (continuous layer)).
What factory test certificates are supplied with EGPF?
Every production drum or spool of EGPF undergoes routine conductor DC resistance, dimensional and dielectric/integrity testing per NF M 87-202 / IEC 60332-3, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for EGPF

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

NF M 87-202 EGPF Lead-Sheathed & Steel-Tape Armoured Hydrocarbon Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote