Immersion & wet locations
Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers
Product
Heavy-Duty 2-10 AWG Subsea Net Cleaner Power Umbilical featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (UL 44 / IEC 60228, 600/1,000 V, -40 to +80 °C, min. bend radius 6 × OD).
Typical values for this cable type, based on UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification — confirmed in the datasheet and quotation for your order.
Application fit
Heavy-Duty 2-10 AWG Subsea Net Cleaner Power Umbilical featuring flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath (UL 44 / IEC 60228, 600/1,000 V, -40 to +80 °C, min. bend radius 6 × OD).
Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers
Contra-helical galvanized steel wire armour or high-modulus aramid/LCP braid supports vertical traction winches, TMS cages and tow sheaves
Torque-balanced armour or neutrally buoyant foamed-PUR jacket prevents hockling and kinking during free-swimming ROV and tether excursions
Resists seawater, marine bio-fouling, hydraulic oil, UV radiation and abrasion across vessel A-frames and launch-and-recovery systems (LAR
Subsea ROV umbilicals and tow cables are optimized for winch deployment and water-column catenaries rather than high-speed factory drag ch
Use Drag-Chain Feeder CableConstruction
Shown: 2-10 AWG Net Cleaner Umbilical (UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification) featuring flexible stranded copper conductors (5 cores), cross-linked elastomeric / polymer core insulation and subsea / marine outer protective sheath (4-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (5 C | Class 5/ class 6 copper conductors |
| 2 | Cross-Linked Elastomeric / Polymer Core | Cross-linked polyethylene (xlpe) insulation |
| 3 | Water-Blocking Tape & Inner Bedding | Hydrostatic water-blocking filler and low-friction separator wrap |
| 4 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification with flexible stranded copper conductors (5 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| 2-10 AWG Net Cleaner Umbilical Construction Schedule (−40…+80 °C) | |||||||
| 2-10 AWG Net Cleaner Umbilical 4G4.0 mm² | 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | IEC 60228 Class 5 Cu/SnCu | 14.2 | 340 | 3.2 | 85 | |
| 2-10 AWG Net Cleaner Umbilical 4G16 mm² | 4G16 mm² (3×16 + 1G16 / 6 AWG) | IEC 60228 Class 5 Cu/SnCu | 21.4 | 840 | 9.6 | 130 | |
| 2-10 AWG Net Cleaner Umbilical 3×50+1G25 mm² | 3 × 50 + 1G25 mm² (or 3×70+1G35) | IEC 60228 Class 5 Cu/SnCu | 32.8 | 2,240 | 26.5 | 195 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 4G4.0 mm² (3×4.0 + 1G4.0 / 12 AWG) | 4.95 | 600/1,000 V (36 A Submersible) | −40…+80 °C |
| 4G16 mm² (3×16 + 1G16 / 6 AWG) | 1.21 | 600/1,000 V (98 A Submersible) | −40…+80 °C |
| 3 × 50 + 1G25 mm² (or 3×70+1G35) | 0.39 | 600/1,000 V (195 A Feeder) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification) | Zero dielectric breakdown and verified wet insulation resistance for 600/1,000 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (UL 44 & IEC 60228 Subsea Net Cleaner Power Umbilical Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.