HDT SAE J1128 Heavy-Duty Primary WireHDT SAE J1128 Heavy-Duty Primary Wire manufactured to SAE J1128 / ASTM B3 Heavy-Duty Type HDT, rated 60 V DC and -40°C to +85°C with a 6 × OD minimum bending radius for industrial automation & manufacturing installations.

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Flame-retardant
Oil-resistant
Approved
Order designation
HDT SAE J1128 Heavy-Duty Primary (1×14 AWG)
Outer diameter
4.1 mm
Cable weight
40 kg/km
Min. bend radius
25 mm
Conductor & shield
Class 2 Stranded Plain Copper
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
60 V DC
SAE J1128 / ASTM B3 Heavy-Duty Type HDT
Temperature
-40°C to +85°C
Fixed / flex duty
Min. bend radius
6 × OD
4.1–5.7 mm
Screening
Unshielded
Fixed / flex duty
Outer sheath
Industrial PVC
Oil & sunlight resistant
Core / size range
3 sizes
3 standard configurations

Typical values for this cable type, based on Reference specification per SAE J1128 / ASTM B3 Heavy-Duty Type HDT (HDT SAE J1128 Heavy-Duty Primary) — confirmed in the datasheet and quotation for your order.

Application fit

Is HDT SAE J1128 Heavy-Duty Primary right for your machine?

Engineered for industrial installations requiring verified electrical, mechanical and environmental performance.

Fixed installation

Suitable

Approved for cable tray, duct, direct burial or clipped fixed installations per applicable wiring regulations.

Motor stator, traction & converter leads

Suitable

Flexible stranded conductors withstand equipment vibration, mobile hook-ups and routine flexing.

Energy chain / drag chain

With conditions

Fixed or moderate-flex construction; for continuous high-acceleration drag chains, select a dedicated Class 6 chain cable.

Offshore platform & shipboard deck trays

Suitable

Outer sheath compound resists industrial oils, moisture ingress, abrasion and outdoor weathering.

Vertical / spreader reel

Not suitable

Not intended for high-tension crane spreader reeling drums; select a dedicated 2PNCT or 3PNCT reeling cable.

Use TRA 0.6/1 kV PUR Reeling Cable

Vehicle engine bay & HV bus harness

Suitable

Fluid- and heat-resistant 60 V DC PVC thin-wall design routes cleanly through compact vehicle engine bays and HV chassis looms.

Typical machinesAutomotive & Commercial VehiclesPower distribution & utility networksRailways, tunnels & public infrastructureProcess instrumentation & oil/gas skidsIndustrial automation & control cabinetsRenewable energy, marine & heavy industry

Construction

Layer by layer

Cross-section colours are aligned to the supplied product cutaway; layer dimensions follow the reference specification.

HDT SAE J1128 Heavy-Duty Primary – Layered cable cutaway
Layer cutaway
#LayerMaterial & reference
1Conductor1×14 AWG (19/0.36 mm Soft-Annealed Bare Copper)
2Insulation & Core IdentificationSAE J1128 heavy-duty primary PVC inner dielectric
3Screen / Bedding / Armour Layer1.14 mm heavy-duty extruded wall concentric mechanical barrier (SAE J1128 Type HDT)
4Outer Protective SheathGreen heavy-duty thick-wall SAE J1128 HDT PVC insulation jacket (OD 4.10 mm)

1×14 AWG

Class 2 Stranded Plain Copper · Outer diameter 4.1 mm

1×12 AWG

Class 2 Stranded Plain Copper · Outer diameter 4.8 mm

1×10 AWG

Class 2 Stranded Plain Copper · Outer diameter 5.7 mm

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on Reference specification per SAE J1128 / ASTM B3 Heavy-Duty Type HDT (HDT SAE J1128 Heavy-Duty Primary). Values for your order are confirmed in the datasheet and quotation.

Electrical

Nominal / reference voltage
60 V DC
Conductor & core insulation
1×14 AWG (19/0.36 mm Soft-Annealed Bare Copper) · SAE J1128 heavy-duty primary PVC inner dielectric
Routine dielectric / continuity test
100% factory drum spark & continuity verified

Thermal

Operating temperature range
-40°C to +85°C
Short-circuit / peak thermal limit
+160 °C to +250 °C (5 s conductor thermal limit)
Flame & fire performance
SAE J1128 / ASTM B3 Heavy-Duty Type HDT

Mechanical

Minimum bending radius
6 × OD
Screening / armour architecture
1.14 mm heavy-duty extruded wall concentric mechanical barrier (SAE J1128 Type HDT)
Outer sheath material & colour
Green heavy-duty thick-wall SAE J1128 HDT PVC insulation jacket (OD 4.10 mm)

Reference standards

Reference standard
SAE J1128 / ASTM B3 Heavy-Duty Type HDT
Hazardous Substance Compliance
CE, UKCA, RoHS 2 (2011/65/EU) & REACH SVHC compliant
Quality & Batch Traceability
EN 10204 3.1 Factory Inspection Certificate

Sizes

Sizes & engineering data

Representative configurations from the series specification; select a row to prefill the quotation tool.

All sizes
ConfigurationConductor & shieldInsulation / wallOuter sheathOuter diameter
mm
Min. bend radius
mm
Max. conductor resistance @ 20 °C
Ω/km
Copper weight
kg/km
Cable weight
kg/km
Key electrical / optical ratingPart designationEnquiry
HDT SAE J1128 Heavy-Duty Primary
1×14 AWGClass 2 Stranded Plain CopperSAE J1128 heavy-duty primary PVC inner dielectricIndustrial PVC4.1258.7020.84015 AHDT SAE J1128 Heavy-Duty Primary (1×14 AWG)
1×12 AWGClass 2 Stranded Plain CopperSAE J1128 heavy-duty primary PVC inner dielectricIndustrial PVC4.8295.4728.65520 AHDT SAE J1128 Heavy-Duty Primary (1×12 AWG)
1×10 AWGClass 2 Stranded Plain CopperSAE J1128 heavy-duty primary PVC inner dielectricIndustrial PVC5.7343.4439.07530 AHDT SAE J1128 Heavy-Duty Primary (1×10 AWG)
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Dimensions and weights are nominal manufacturing targets subject to standard production tolerances.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor resistance & continuityWithin maximum Ω/km limit at 20 °C per IEC 60228 / BS EN 60228Every manufactured drum length
Dielectric withstand / spark testNo breakdown across insulation, screen or armourEvery manufactured drum length
Sample tests
Vertical flame propagation & jacket qualificationSelf-extinguishing and compliant with reference standard limitsType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

SAE J1128 / ASTM B3 Heavy-Duty Type HDT CompliantEN 10204 3.1 Factory Test CertificateCE, UKCA, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

HDT SAE J1128 HEAVY-DUTY PRIMARY WIRE / TEBAOFLEX.COM — sequential metre marking
Delivery form
Heavy-duty export fumigated wooden drums or steel reels with moisture-sealed ends
Standard lengths
250 m, 500 m, 1000 m continuous drum lengths or custom cut-to-length runs
MOQ
100 m (standard configurations) · 300 m (custom builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-11-04
Updated
2026-11-04

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What applications is HDT SAE J1128 Heavy-Duty Primary designed for?
HDT SAE J1128 Heavy-Duty Primary is engineered for industrial automation & manufacturing installations under SAE J1128 / ASTM B3 Heavy-Duty Type HDT, operating over -40°C to +85°C with a minimum bending radius of 6 × OD.
How is HDT SAE J1128 Heavy-Duty Primary constructed across its layers?
Its 4-layer architecture combines 1×14 AWG (19/0.36 mm Soft-Annealed Bare Copper) with SAE J1128 heavy-duty primary PVC inner dielectric, 1.14 mm heavy-duty extruded wall concentric mechanical barrier (SAE J1128 Type HDT) and Green heavy-duty thick-wall SAE J1128 HDT PVC insulation jacket (OD 4.10 mm).
What standards and routine factory tests apply to HDT SAE J1128 Heavy-Duty Primary?
Every manufactured drum is tested to SAE J1128 / ASTM B3 Heavy-Duty Type HDT for conductor continuity, dielectric voltage withstand and sheath integrity, supplied with an EN 10204 3.1 inspection certificate.
What sizes and drum lengths are available for HDT SAE J1128 Heavy-Duty Primary?
Representative sizes include 1×14 AWG, 1×12 AWG and 1×10 AWG, supplied on 250 m, 500 m or 1,000 m export drums or custom cut lengths.
Which technical documents are available?
Reference files are provided for project screening. Final parameters and the applicable document package are confirmed during quotation.

Request a quote

Get an engineering quote for HDT SAE J1128 Heavy-Duty Primary

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

HDT SAE J1128 Heavy-Duty Primary Wire

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 