Motorised monospiral reel
Integrated contra-helical aramid anti-torsion braid and high-tear-strength PUR/rubber sheath withstand continuous monospiral and level-win
Product
DR 717 P/ DR 718 CP Highflex PUR Reeling Cable featuring power supply conductors (4 cores) and subsea / marine outer protective sheath (DIN VDE 0250-814 / UL AWM, 0.6/1 kV (300/500 V), -40 to +80 °C, min. bend radius 5 × OD).
Typical values for this cable type, based on DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard — confirmed in the datasheet and quotation for your order.
Application fit
DR 717 P/ DR 718 CP Highflex PUR Reeling Cable featuring power supply conductors (4 cores) and subsea / marine outer protective sheath (DIN VDE 0250-814 / UL AWM, 0.6/1 kV (300/500 V), -40 to +80 °C, min. bend radius 5 × OD).
Integrated contra-helical aramid anti-torsion braid and high-tear-strength PUR/rubber sheath withstand continuous monospiral and level-win
Engineered per DIN VDE 0250-813/814 and IEC/IEEE 80005-1 for high tensile loads, multi-layer drum coiling and S-bend sheave deflection.
Submersible ether-PUR and marine polychloroprene outer jackets operate in wet deck, splash-zone and shallow-subsea crawler duty.
Resists seawater, hydraulic oil, diesel, UV radiation and severe abrasion across deck rollers and quayside cable trenches.
Heavy drum-reeling cables are optimized for tensile winch coiling rather than tight-radius high-acceleration drag chains.
Use MF-512-PUR Feeder Chain CableConstruction
Shown: DR 717 P / DR 718 CP Highflex Reel (DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard) featuring power supply conductors (4 cores), shielded data twisted pairs (4×2) and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Power Supply Conductors (4 Cores) | Stranded copper power cores with Thermoplastic elastomer (TPE) core insulation |
| 2 | Shielded Data Twisted Pairs (4×2) | Impedance-controlled twisted pairs for Ethernet / RS-485 / DMX |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard with power supply conductors (4 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| DR 717 P / DR 718 CP Highflex Reel Construction Schedule (−40…+80 °C) | |||||||
| DR 717 P 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| DR 717 P 4×2×0.50 + 2×1.5 | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| DR 717 P 4×2×0.75 + 4×2.5 | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 0.6/1 kV (300/500 V) (4–20 mA / DO) | −40…+80 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 0.6/1 kV (300/500 V) (CTD / Multi-Sensor) | −40…+80 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 0.6/1 kV (300/500 V) (ROV / Camera / LED) | −40…+80 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard) | DC resistance at 20 °C, optical attenuation and wall thickness within DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard) | Zero dielectric breakdown and verified wet insulation resistance for 0.6/1 kV (300/500 V) rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DIN VDE 0250-814 DR 717 P / DR 718 CP Highflex PUR Marine Reeling Standard) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+80 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.