Immersion & wet locations
Neoprene/PUR overmolded boots and rolling-seal or wiping-pin wet-mate contacts operate reliably up to 600–700 bar (6,000–7,000 m) depth.
Product
Type 624772 M12 8-Pole Digital DO & Salinity Cable featuring flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath (IEC 61076-2-101 / EN 50288, 60 V / 300 V, -30 to +85 °C, min. bend radius 5 × OD).
Typical values for this cable type, based on IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification — confirmed in the datasheet and quotation for your order.
Application fit
Type 624772 M12 8-Pole Digital DO & Salinity Cable featuring flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath (IEC 61076-2-101 / EN 50288, 60 V / 300 V, -30 to +85 °C, min. bend radius 5 × OD).
Neoprene/PUR overmolded boots and rolling-seal or wiping-pin wet-mate contacts operate reliably up to 600–700 bar (6,000–7,000 m) depth.
Flexible stranded copper/optical leads and strain-relieved backshells handle ocean glider fin motion, ROV manipulator articulation and jum
Plug-and-play bulkhead and inline mating simplifies subsea sensor integration on AUV hulls, benthic landers and CTD frames.
316L stainless steel, titanium or marine bronze shells and UV/oil-resistant elastomers survive deck handling and IP69K caustic washdown.
Pre-terminated wet-mate whips and sensor jumpers are equipment interconnects, not long-length reeling drum cables.
Use C-3600 ROV Tether AssemblyConstruction
Shown: Type 624772 M12-8P DO/Salinity (IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification) featuring flexible stranded copper conductors (7 cores), copper wire braid emc screen and subsea / marine outer protective sheath (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Flexible Stranded Copper Conductors (7 C | Class 5 / Class 6 copper conductors with High-stiffness polypropylene (PP) core insulation |
| 2 | Copper Wire Braid EMC Screen | High-coverage braided copper shield for EMI/VFD protection |
| 3 | Subsea / Marine Outer Protective Sheath | Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath |
Built to IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification with flexible stranded copper conductors (7 cores) and subsea / marine outer protective sheath
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Type 624772 M12-8P DO/Salinity Construction Schedule (−30…+85 °C) | |||||||
| Type 624772 M12-8P DO 2×2×0.50 mm² | 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | Stranded SnCu + Foil/TCWB + Subsea PUR | 8.4 | 98 | 2.5 | 50 | |
| Type 624772 M12-8P DO 4×2×0.50 + 2×1.5 | 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | Stranded SnCu + Individual/Overall Shield | 11.8 | 195 | 5.2 | 70 | |
| Type 624772 M12-8P DO 4×2×0.75 + 4×2.5 | 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | Stranded SnCu + Aramid/Armour + PUR | 15.2 | 360 | 12.0 | 95 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 2 × 2 × 0.50 mm² (20 AWG) + Vent/Drain | 39.00 | 60 V / 300 V (4–20 mA / DO) | −30…+85 °C |
| 4 × 2 × 0.50 + 2 × 1.5 mm² Hybrid | 39.00 | 60 V / 300 V (CTD / Multi-Sensor) | −30…+85 °C |
| 4 × 2 × 0.75 + 4 × 2.5 mm² Subsea | 26.00 | 60 V / 300 V (ROV / Camera / LED) | −30…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification) | Zero dielectric breakdown and verified wet insulation resistance for 60 V / 300 V rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (IEC 61076-2-101 M12 8-Pole Digital DO & Salinity Sensor Cable Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −30…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.