Contact
subsea ROV umbilical, AUV tether & sonar tow cableITU-T G.972 / CIGRE TB 4901.8/3 kV (-20 to +70 °C)Subsea / Marine Outer Protective She

M-PAC Seafloor Observatory & BMS Umbilical CableITU-T G.972 / CIGRE TB 490 — 1.8/3 kV — -20 to +70 °C Subsea & Marine Cable

M-PAC Seafloor Observatory & BMS Umbilical Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (ITU-T G.972 / CIGRE TB 490, 1.8/3 kV, -20 to +70 °C, min. bend radius 15 × OD).

Water-resistant
Ozone, UV & moisture
Outdoor & humid
Approved
Order designation
M-PAC Seafloor Observatory 3×6 + 4×SM + 2TP
Outer Ø ≈
20.8 mm
Net weight ≈
1,280 kg/km
Max. pulling ≈
115.0 kN
Core / stranding
SnCu + Gel Tube + Contra-Helical GSWA
All sizes (3)
Engineering reply in 2 business hoursCut-to-length export drumsEN 10204 3.1 certificate per drum
Rated voltage
1.8/3 kV
Tested per ITU-T G.972 / CIGRE TB 490
Operating temp.
−20…+70 °C
Subsea, deck & cold-water duty
Min. bend radius
15 × OD
Winch sheave, TMS & subsea routing
Core / conductor
Single-Mode / Mu
Hermetic stainless-steel tube / tight-bu
Outer protection
Subsea / Marine
Black hydrolysis- & abrasion-resistant m
Standard
ITU-T G.972 / CI
ITU-T G.972 & CIGRE TB 490 M-PAC Seafloo

Typical values for this cable type, based on ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard — confirmed in the datasheet and quotation for your order.

Application fit

Is M-PAC Seafloor Observatory right for your machine?

M-PAC Seafloor Observatory & BMS Umbilical Cable featuring single-mode / multi-mode optical unit and subsea / marine outer protective sheath (ITU-T G.972 / CIGRE TB 490, 1.8/3 kV, -20 to +70 °C, min. bend radius 15 × OD).

Immersion & wet locations

Suitable

Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers

Vertical / spreader reel

Suitable

Contra-helical galvanized steel wire armour or high-modulus aramid/LCP braid supports vertical traction winches, TMS cages and tow sheaves

Free-hanging vertical run

Suitable

Torque-balanced armour or neutrally buoyant foamed-PUR jacket prevents hockling and kinking during free-swimming ROV and tether excursions

Offshore platform & shipboard deck trays

Suitable

Resists seawater, marine bio-fouling, hydraulic oil, UV radiation and abrasion across vessel A-frames and launch-and-recovery systems (LAR

Energy chain / drag chain

Not suitable

Subsea ROV umbilicals and tow cables are optimized for winch deployment and water-column catenaries rather than high-speed factory drag ch

Use Drag-Chain Feeder Cable
Typical machinesUnderwater & Ocean ExplorationWork-Class & Observation ROV Umbilicals and TMS TethersOffshore Aquaculture Net Cleaners & Subsea Cage InspectionAUV, Ocean Glider & Expendable Spool-Payoff Micro-TethersUSV Towed Sonar Arrays, Seabed Crawlers & Subsea Trenchers

Construction

Layer by layer

Shown: M-PAC Seafloor Observatory (ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard) featuring single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath (4-layer construction).

M-PAC Seafloor Observatory — stepped horizontal cutaway showing Single-Mode / Multi-Mode Optical Unit and Subsea / Mar
Layer cutaway
#LayerMaterial & reference
1Single-Mode / Multi-Mode Optical UnitHermetic stainless-steel tube / tight-buffered optical unit
2Power & Control Copper ConductorsStranded copper conductors with Cross-linked polyethylene (XLPE) insulation
3Galvanized Steel Wire ArmourHigh-strength galvanized steel wire armour layer
4Subsea / Marine Outer Protective SheathBlack hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath

M-PAC Seafloor Observatory — Standard Subsea & Marine Execution

Built to ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard with single-mode / multi-mode optical unit and subsea / marine outer protective sheath

M-PAC Seafloor Observatory — Custom Winch Length / Molded Termination

Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets

M-PAC Seafloor Observatory — Hydrostatic & Routine Certified

Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report

Technical data

Ratings & operating limits

Typical values: Typical values for this cable type, based on ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard. Values for your order are confirmed in the datasheet and quotation.

Electrical

Rated voltage / operating system
1.8/3 kV (ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard)
Core / conductor construction
Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit
Primary dielectric / optical buffer
Power & Control Copper Conductors — Stranded copper conductors with Cross-linked polyethylene (XLPE) insulation

Thermal

Continuous operating temperature
−20…+70 °C (submerged seawater & topside deck service)
Hydrostatic & thermal cycling endurance
Verified cold-bend and wet dielectric stability across −20…+70 °C per ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard
Storage & transport temperature
−40…+80 °C on export wooden/steel cable drum

Mechanical

Outer jacket / sheath protection
Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath
Minimum bending radius
15 × OD
Reinforcement / screen / bedding layer
Galvanized Steel Wire Armour — High-strength galvanized steel wire armour layer

Resistance

Seawater, hydrolysis & oil resistance
Resistant to permanent seawater immersion, hydrolysis, hydraulic oil and bio-fouling per ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard
Hydrostatic pressure & water blocking
Radial and longitudinal water-blocking integrity verified per ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard
RoHS & REACH compliance
RoHS 2 (2011/65/EU + 2015/863) & REACH SVHC compliant

Reference standards

Governing standard
ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard
Subsea & conductor qualification standards
IEC 60228 / DNV-ST-E402 / ISO 13628-5 / IEC 60794 / EN 10204
Quality management & inspection
ISO 9001:2015 & EN 10204 3.1 factory routine inspection

Identification

Model designation
M-PAC Seafloor Observatory
Sheath colour & metre marking
Continuous metre-marked black outer finish (Subsea / Marine )
Customs tariff (HS)
8544.49 / 8544.60 / 8544.70

Sizes

3 standard M-PAC Seafloor Observatory configurations

Manufactured to ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.

Dimensions, tensile load & weights
Order designationConfigurationCore / strandingOuter Ø ≈
mm
Net weight ≈
kg/km
Max. pulling
kN ≈
Min. bend R
mm
Enquiry
M-PAC Seafloor Observatory Construction Schedule (−20…+70 °C)
M-PAC Seafloor Observatory 3×6 + 4×SM + 2TP3×6 mm² Power + 4×SM Fiber + 2×2×0.75SnCu + Gel Tube + Contra-Helical GSWA20.81,280115.0250
M-PAC Seafloor Observatory 3×10 + 6×SM + 4TP3×10 mm² Power + 6×SM Fiber + 4×2×0.75SnCu + SS Tube + Double Steel Armour25.41,890185.0305
M-PAC Seafloor Observatory 3×16 + 8×SM/MM3×16 mm² Power + 8×SM/MM + 3×2×1.0SnCu + SS Tube + Heavy GSWA Pack30.22,680260.0365
  • Typical values for this cable type; dimensions and weights for your order are confirmed in the quotation.
  • Custom core counts, optical fiber channels, wet-mate terminations and continuous winch lengths available per ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard.

Quality & approvals

Testing & inspection

Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.

  1. ConductorClass 5 stranding
  2. Spark test100 % in-line
  3. Lay-upCores, earth, fillers
  4. SheathingInner, braid / screen, outer
  5. Electrical testsAC voltage, resistance
  6. DimensionsOD, wall thickness
  7. Inspection documents & dispatchDrum & dispatch
Testing & inspectionTest value / referenceFrequency
Routine tests
Conductor DC resistance / OTDR optical & dimensional check (ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard)DC resistance at 20 °C, optical attenuation and wall thickness within ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard limitsEvery manufactured drum length
AC high-voltage dielectric & insulation resistance test (ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard)Zero dielectric breakdown and verified wet insulation resistance for 1.8/3 kV ratingEvery manufactured drum length
Sample tests
Hydrostatic pressure, tensile load & seawater immersion qualification (ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard)Verified hydrostatic pressure integrity, breaking load and flex endurance across −20…+70 °CType qualification & periodic lot audit

Inspection certificate

Issued with every drum, listing the routine test results for that length.

Product approvals

ITU-T G.972 / CIGRE TB 490 CompliantEN 10204 3.1 Factory Test CertificateCE, RoHS 2 (2011/65/EU) & REACH

Company certificates

ISO 9001ISO 14001ISO 45001VDE marks approvalUL / cULCE · LVD / EMC

Marking & supply

Ordering & delivery

Sheath marking

TEBAOFLEX M-PAC Seafloor Observatory ITU-T G.972 / CIGRE TB 490 1.8/3 kV CE
Delivery form
Heavy-duty export fumigated wooden drums, steel winch reels or pre-terminated subsea assemblies
Standard lengths
500 m, 1,000 m, 3,000 m continuous winch lengths or custom cut-to-length subsea jumpers
MOQ
100 m (standard configurations) · 300 m (custom subsea builds)
Lead time
2–4 weeks ex-works
Incoterms
EXW, FCA, FOB, CIF, DAP

Technical documents

Downloads

Revision
2026-10-29
Updated
2026-10-29

FAQ

Questions engineers ask first

Not covered here? Send your drawing — an engineer replies within 2 business hours.

What governing standard and construction define M-PAC Seafloor Observatory (M-PAC Seafloor Observatory & BMS Umbilical Cable)?
M-PAC Seafloor Observatory (M-PAC Seafloor Observatory & BMS Umbilical Cable) is manufactured in accordance with ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard for 1.8/3 kV subsea,ROV and marine aquaculture service over -20 to +70 °C. Its 4-layer construction comprises single-mode / multi-mode optical unit, power & control copper conductors and subsea / marine outer protective sheath.
What is the minimum bending radius and operating temperature range for M-PAC Seafloor Observatory?
The minimum bending radius for M-PAC Seafloor Observatory is 15 × OD across its continuous operating temperature range of -20 to +70 °C, ensuring mechanical flex endurance and hydrostatic reliability in subsea winches, TMS cages and aquaculture installations.
How are the concentric layers of M-PAC Seafloor Observatory arranged from inside to outside?
From inside to outside, the construction sequence is: (01) Single-Mode / Multi-Mode Optical Unit — Hermetic stainless-steel tube / tight-buffered optical unit; (02) Power & Control Copper Conductors — Stranded copper conductors with Cross-linked polyethylene (XLPE) insulation; (03) Galvanized Steel Wire Armour — High-strength galvanized steel wire armour layer; (04) Subsea / Marine Outer Protective Sheath — Black hydrolysis- & abrasion-resistant marine Polyurethane (PUR) outer sheath.
What factory test certificates are supplied with M-PAC Seafloor Observatory?
Every production drum of M-PAC Seafloor Observatory undergoes routine conductor DC resistance / optical OTDR continuity, AC high-voltage dielectric and dimensional testing per ITU-T G.972 & CIGRE TB 490 M-PAC Seafloor Observatory Umbilical Standard, and is delivered with an EN 10204 3.1 factory test certificate.

Request a quote

Get an engineering quote for M-PAC Seafloor Observatory

Your selection and application details are copied into the enquiry form below.

01Selected sizes

Use + Add next to a size or configuration.

02Reel & motion

Add your operating conditions here to include them in your enquiry.

03Message for our engineers

M-PAC Seafloor Observatory & BMS Umbilical Cable

Selected sizes:


Reel & motion:
- Reel type: 
- Drum core diameter (mm): 
- Cable length on drum (m): 
- Travel speed (m/min): 
- Max. acceleration: 
- Cycles per hour: 
- Length and quantity: 
- Ambient temperature: 
- Exposure (outdoor, water, oil, abrasion): 
- Destination country: 
- Equipment and operating conditions: 
Send via WhatsApp

DatasheetRequest a quote