Immersion & wet locations
Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers
Product
Custom Electro-Optic Armored Tow Cable featuring optical fiber & 75-ohm coaxial units and double torque-balanced steel wire armour (DNV-ST-E402 / MIL-DTL-24643, 1.8/3 kV, -40 to +85 °C, min. bend radius 12 × OD).
Typical values for this cable type, based on DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification — confirmed in the datasheet and quotation for your order.
Application fit
Custom Electro-Optic Armored Tow Cable featuring optical fiber & 75-ohm coaxial units and double torque-balanced steel wire armour (DNV-ST-E402 / MIL-DTL-24643, 1.8/3 kV, -40 to +85 °C, min. bend radius 12 × OD).
Hydrolysis-resistant subsea PUR or HDPE outer sheath and water-blocked core interstices withstand continuous deep-ocean hydrostatic immers
Contra-helical galvanized steel wire armour or high-modulus aramid/LCP braid supports vertical traction winches, TMS cages and tow sheaves
Torque-balanced armour or neutrally buoyant foamed-PUR jacket prevents hockling and kinking during free-swimming ROV and tether excursions
Resists seawater, marine bio-fouling, hydraulic oil, UV radiation and abrasion across vessel A-frames and launch-and-recovery systems (LAR
Subsea ROV umbilicals and tow cables are optimized for winch deployment and water-column catenaries rather than high-speed factory drag ch
Use Drag-Chain Feeder CableConstruction
Shown: Custom Electro-Optic Armored Tow (DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification) featuring optical fiber & 75-ohm coaxial units, flexible copper power & control cores and double torque-balanced steel wire armour (3-layer construction).

| # | Layer | Material & reference |
|---|---|---|
| 1 | Optical Fiber & 75-Ohm Coaxial Units | Central stainless-steel optical tube + shielded coaxial video core |
| 2 | Flexible Copper Power & Control Cores | Stranded copper conductors with High-stiffness polypropylene (PP) core insulation |
| 3 | Double Torque-Balanced Steel Wire Armour | Contra-helical high-tensile galvanized steel wire armour |
Built to DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification with optical fiber & 75-ohm coaxial units and double torque-balanced steel wire armour
Available on continuous export winch drums or factory-terminated with subsea wet-mate / mechanical sockets
Supplied with EN 10204 3.1 routine dielectric, conductor/optical continuity & hydrostatic qualification report
Technical data
Sizes
Manufactured to DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification for subsea robotics, ROV umbilicals, marine aquaculture and offshore sensor applications.
| Order designation | Configuration | Core / stranding | Outer Ø ≈ mm | Net weight ≈ kg/km | Max. pulling kN ≈ | Min. bend R mm | Enquiry |
|---|---|---|---|---|---|---|---|
| Custom Electro-Optic Armored Tow Construction Schedule (−40…+85 °C) | |||||||
| Custom Electro-Optic Armored Tow 3×6 + 4×SM + 2T | 3×6 mm² Power + 4×SM Fiber + 2×2×0.75 | SnCu + Gel Tube + Contra-Helical GSWA | 20.8 | 1,280 | 115.0 | 250 | |
| Custom Electro-Optic Armored Tow 3×10 + 6×SM + 4 | 3×10 mm² Power + 6×SM Fiber + 4×2×0.75 | SnCu + SS Tube + Double Steel Armour | 25.4 | 1,890 | 185.0 | 305 | |
| Custom Electro-Optic Armored Tow 3×16 + 8×SM/MM | 3×16 mm² Power + 8×SM/MM + 3×2×1.0 | SnCu + SS Tube + Heavy GSWA Pack | 30.2 | 2,680 | 260.0 | 365 | |
| Configuration | Max. DC R₂₀ Ω/km | Rating / Impedance / Load | Operating temp. |
|---|---|---|---|
| 3×6 mm² Power + 4×SM Fiber + 2×2×0.75 | 3.30 | 1.8/3 kV · 115 kN MBS | −40…+85 °C |
| 3×10 mm² Power + 6×SM Fiber + 4×2×0.75 | 1.91 | 1.8/3 kV · 185 kN MBS | −40…+85 °C |
| 3×16 mm² Power + 8×SM/MM + 3×2×1.0 | 1.21 | 1.8/3 kV · 260 kN MBS | −40…+85 °C |
Quality & approvals
Routine tests on every production length, sample and type tests per batch — documented on an EN 10204 3.1 inspection certificate.
| Testing & inspection | Test value / reference | Frequency |
|---|---|---|
| Routine tests | ||
| Conductor DC resistance / OTDR optical & dimensional check (DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification) | DC resistance at 20 °C, optical attenuation and wall thickness within DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification limits | Every manufactured drum length |
| AC high-voltage dielectric & insulation resistance test (DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification) | Zero dielectric breakdown and verified wet insulation resistance for 1.8/3 kV rating | Every manufactured drum length |
| Sample tests | ||
| Hydrostatic pressure, tensile load & seawater immersion qualification (DNV-ST-E402 Custom Electro-Optic Double-Armored Subsea Tow Specification) | Verified hydrostatic pressure integrity, breaking load and flex endurance across −40…+85 °C | Type qualification & periodic lot audit |
Marking & supply
Sheath marking
Technical documents
FAQ
Not covered here? Send your drawing — an engineer replies within 2 business hours.
Request a quote
Your selection and application details are copied into the enquiry form below.
Use + Add next to a size or configuration.
Add your operating conditions here to include them in your enquiry.