Instalación fija
Public building BMS, incendio detección & alarm lazos (Rojo BMK), LSA patch panels y HVAC risers.
Producto
DIN VDE 0815 static-lámina apantallado libre de halógenos (LSZH) sólido-par installation cable
Valores típicos para este tipo de cable, basados en DIN VDE 0815 (J-H(St)H...Bd) · LSZH — confirmados en la ficha técnica y oferta de su pedido.
Aplicaciones
Baja emisión de humos libre de halógenos (`LSZH`) building installation, incendio-alarm (`BMK`) y BMS cable a DIN VDE 0815 (`J-H(St)H...Bd`) con sólido 0.6/0.8 mm conductores de cobre, libre de halógenos poliolefina conductores (`H`), Al/ PET static pantalla (`(St)`) y HM2 LSZH cubierta (`H`).
Public building BMS, incendio detección & alarm lazos (Rojo BMK), LSA patch panels y HVAC risers.
Static Al/ PET lámina pantalla rejects electrostática noise; para flexible multipolar trenzado EMC, select LiHCH.
Uso LiHCH TrenzadoSólido Class 1 conductores de cobre (0.6 / 0.8 mm); strictly para fijo installation.
Uso LiHCH FlexibleConstrucción
Mostrado: J-H(St)H 4×2×0.8 Bd — sólido 0.8 mm conductores de cobre desnudo, libre de halógenos poliolefina Aislamiento de conductor ('H') trenzado en pares/haces ('Bd'), libre de halógenos cinta, Al/ PET static lámina pantalla ('(St)') con sólido estañado drenaje alambre y pebble-gris RAL 7032 HM2 LSZH cubierta exterior ('H').
| # | Capa | Material y referencia |
|---|---|---|
| 1 | Sólido desnudo conductor de cobre | Sólido circular cobre recocido alambre Ø 0.6 mm (≈ 0.28 mm²) o Ø 0.8 mm (≈ 0.50 mm²) para LSA/IDC terminationDIN VDE 0815 / IEC 60228 Cl. 1 |
| 2 | Libre de halógenos LSZH Aislamiento de conductor (H) | Reticulado o termoplástico libre de halógenos poliolefina compuesto Type HI1 / HI2 (DIN VDE 0207-24)DIN VDE 0815 · HI2 |
| 3 | Libre de halógenos envoltura cinta | Solapado libre de halógenos plástico cinta sobre el en pares unidad haces ('Bd')DIN VDE 0815 |
| 4 | Static Al/ PET lámina pantalla (St) | Plástico-laminated aluminio lámina cinta con un longitudinal sólido de cobre estañado drenaje alambreDIN VDE 0815 |
| 5 | Libre de halógenos LSZH cubierta exterior (H) | Retardante de la llama baja emisión de humos libre de halógenos compuesto Type HM2, pebble-gris RAL 7032 (o rojo RAL 3000 para incendio alarm)DIN VDE 0207-24 HM2 · IEC 60332-3-24 |
Libre de halógenos telecommunications, intercom y LSA punch-hasta installation cable de 1×2×0.6 a 40×2×0.6
Libre de halógenos BMS, HVAC actuator y sensor bus cable de 1×2×0.8 a 20×2×0.8 (bucle ≤ 73.2 Ω/km)
Libre de halógenos rojo incendio-alarm bucle cable ('Brandmeldekabel') para public buildings
Datos técnicos
Dimensiones
Typical DIN VDE 0815 (J-H(St)H...Bd) · LSZH exterior diámetro limita, cobre content y cable peso.
| Designación de pedido | Conductores × mm² | AWG ≈ | Ø ext. mín. mm | Ø ext. máx. mm | Cobre kg/km | Peso ≈ kg/km | Radio mín. curvatura mm | Consulta |
|---|---|---|---|---|---|---|---|---|
| n × 2 × 0.6 mm (Ø Sólido Cu, Bucle ≤ 130 Ω/km) LSZH DIN VDE 0815 | ||||||||
| J-H(St)H 1×2×0.6 Bd | 1×2×0.6 | 23 (0.6 mm) | 4.3 | 4.7 | 6 | 28 | 38 | |
| J-H(St)H 2×2×0.6 Bd | 2×2×0.6 | 23 (0.6 mm) | 5.0 | 5.4 | 12 | 38 | 43 | |
| J-H(St)H 4×2×0.6 Bd | 4×2×0.6 | 23 (0.6 mm) | 6.2 | 6.7 | 23 | 62 | 54 | |
| J-H(St)H 6×2×0.6 Bd | 6×2×0.6 | 23 (0.6 mm) | 6.9 | 7.5 | 34 | 81 | 60 | |
| J-H(St)H 10×2×0.6 Bd | 10×2×0.6 | 23 (0.6 mm) | 8.4 | 9.1 | 56 | 122 | 73 | |
| J-H(St)H 20×2×0.6 Bd | 20×2×0.6 | 23 (0.6 mm) | 10.9 | 11.8 | 112 | 220 | 94 | |
| J-H(St)H 30×2×0.6 Bd | 30×2×0.6 | 23 (0.6 mm) | 13.0 | 14.1 | 168 | 315 | 113 | |
| J-H(St)H 40×2×0.6 Bd | 40×2×0.6 | 23 (0.6 mm) | 14.7 | 16.0 | 223 | 410 | 128 | |
| n × 2 × 0.8 mm (Ø Sólido Cu, Bucle ≤ 73.2 Ω/km) LSZH DIN VDE 0815 | ||||||||
| J-H(St)H 1×2×0.8 Bd | 1×2×0.8 | 20 | 5.1 | 5.5 | 11 | 39 | 44 | |
| J-H(St)H 2×2×0.8 Bd | 2×2×0.8 | 20 | 5.7 | 6.2 | 21 | 56 | 50 | |
| J-H(St)H 4×2×0.8 Bd | 4×2×0.8 | 20 | 7.8 | 8.5 | 41 | 98 | 68 | |
| J-H(St)H 6×2×0.8 Bd | 6×2×0.8 | 20 | 9.0 | 9.8 | 61 | 136 | 78 | |
| J-H(St)H 10×2×0.8 Bd | 10×2×0.8 | 20 | 11.1 | 12.1 | 101 | 210 | 97 | |
| J-H(St)H 12×2×0.8 Bd | 12×2×0.8 | 20 | 12.0 | 13.0 | 121 | 246 | 104 | |
| J-H(St)H 20×2×0.8 Bd | 20×2×0.8 | 20 | 14.9 | 16.2 | 201 | 395 | 130 | |
| Sección mm² | AWG ≈ | Resistencia CC máx. 20 °C, Ω/km | Único par/conductor 30 °C, un | Multi-haz de conductores 30 °C, un |
|---|---|---|---|---|
| 0.28 | 23 (0.6 mm) | 65 | 4.0 | 3.0 |
| 0.5 | 20 | 39 | 9.0 | 6.0 |
Comprobación del tambor
Una primera comprobación con valores de catálogo. Ingeniería confirma la geometría del tambor, aceleración y tracción en su oferta.
Calidad y homologaciones
Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.
| Ensayos e inspección | Valor de ensayo / referencia | Frecuencia |
|---|---|---|
| Ensayos de rutina | ||
| Ensayo de tensión AC | 0.8 kV AC (50 Hz) | Cada longitud fabricada |
| Resistencia CC del conductor | IEC 60228 / DIN VDE 0815 (J-H(St)H...Bd) · LSZH (cobre desnudo) | Cada longitud fabricada |
| Ensayos por muestreo | ||
| Propagación vertical de la llama | IEC 60332-1-2 / EN 60332-1-2 | Por lote de producción |
| Aislamiento & cubierta material physical properties | DIN VDE 0815 (J-H(St)H...Bd) · LSZH | Homologación de tipo |
Marcado y suministro
Marcado de la cubierta
Documentación técnica
Preguntas frecuentes
¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.
Solicitar presupuesto
La selección y los datos de aplicación se copian al formulario de consulta inferior.
Use + Añadir junto a una medida o configuración.
Añada aquí las condiciones de servicio para incluirlas en su consulta.