IEC 60584-3 Type KX thermocouple câbleIEC 60584-3 / ANSI MC96.1NiCr (+) / NiAl (−) Véritable KXClass 1 (±1.5 °C) · −25…+200 °C

KX / Type K extension Thermocouple CâbleVéritable NiCr / NiAl (Type K) Class 1 & Class 2 thermocouple extension câble

Véritable NiCr / NiAl (Type K) Class 1 & Class 2 thermocouple extension câble

Conception faible CEM
Écran CEM
Ignifuge
Résistant à l’huile
Désignation de commande
KX-PVC-PiMF 4×2×1.0
Ø ext. ≈
12.8 mm
Total masse ≈
212 kg/km
Min. courbure R (fixe)
96 mm
Configuration
4×2×1.0 mm² (7/0.43)
Toutes les dimensions (16)
Réponse technique sous 2 heures ouvréesTourets d’exportation coupés à la longueurCertificat EN 10204 3.1 par touret
Alliage paire
NiCr (+) / NiAl
90Ni10Cr (+) / 95NiMnAlSi (−)
EMF tolerance
Class 1: ±1.5 °C
±25 µV · Class 2: ±2.5 °C
Boucle résistance
≈ 1.00 Ω/m/paire
à 1.0 mm² (0.29 + 0.71 Ω/m)
IEC code couleur
+ Vert / − Wh
Vert gaine extérieure (ou Ex-i Bleu)
ANSI code couleur
+ Jaune / − Rouge
Jaune gaine extérieure (ASTM E230)
Junction temp..
−25…+200 °C
véritable KX alliage EMF calibration

Valeurs types pour ce type de câble, basés sur IEC 60584-3 / ANSI MC96.1 / ASTM E230 — confirmées dans la fiche technique et le devis de votre commande.

Applications

KX / Type K extension convient-il à votre machine ?

De précision Type KX thermocouple extension câble built à IEC 60584-3 et ANSI MC96.1 avec véritable Nickel-Chromium (+ NiCr) et Nickel-Aluminium (− NiAl) conducteurs, Class 1 (±1.5 °C) tolerance, Al/ PET écran et PVC, LSZH, FEP ou SWA construction.

Installation fixe

Adapté

Disponible dans non armé PVC, XLPE/LSZH et haute température FEP/PTFE pour chemins de câbles, conduits et four heads.

Portique de tunnelier TBM et avancement

Adapté

SWA armé exécution (KX-XLPE-SWA / KX-PVC-SWA) est assigné pour direct trench burial dans refineries.

Chemins de câbles offshore et navires

Adapté

UV -stabilised gaine extérieure et résistant à l’humidité isolation protect millivolt EMF signaux outdoors.

Machines typesPetrochemical Cracking & Reformer FurnacesGaz Turbines, Boilers & Puissance GénérationAcier, Aluminium & Chaleur-Treatment FurnacesVerre, Ceramic & Cement KilnsChemical Reactors & Autoclave Surveillance

Construction

Couche par couche

Illustré: KX-PVC -PiMF 4×2×1.0 mm² (IEC 60584-3) avec Class 1 toronné NiCr (+) / NiAl (−) conducteurs, Vert (+) / Blanc (−) numérotés isolation, individuel & collectif Al/ PET écrans et Vert RAL 6018 gaine extérieure.

12345
Schéma sans échelle — généré à partir des données des couches
#CoucheMatériau et référence
1Véritable Type KX thermocouple alliage conducteursPositive (+): Nickel-Chromium (NiCr, non-magnetic) · Negative (−): Nickel-Aluminium (NiAl, slightly magnetic), massif ou à 7 fils toronnéIdentical chemical composition à le Type K thermocouple sensor sur −25 °C à +200 °C
2Repérés par couleurs Isolation de conducteur105 °C résistant à la chaleur PVC, +90 °C XLPE, ou +200/+260 °C FEP/PTFE (IEC: + Vert / − Blanc; ANSI: + Jaune / − Rouge)Élevé isolation résistance empêche millivolt shunt error
3Individuel & collectif Al/ PET écransAluminium/ PET laminated ruban + 0.5 mm² cuivre étamé drain fil (OS ou PiMF+OS)Rejects 50/60 Hz hum et thyristor élément chauffant noise sur faible-niveau ~41 µV/°C signaux
4En option SWA ou cuivre étamé tresseNon armé, tresse en fils de cuivre étamé (CY/SY), ou Galvanisé Acier Fil Armure (SWA)Mécanique protection tailored à indoor chemin de câbles, four tête ou souterrain trench
5Gaine extérieure (IEC Vert, ANSI Jaune ou Ex-i Bleu)Ignifuge PVC, Faible émission de fumée Sans halogène (LSZH), ou fluoropolymère FEP/PTFEIEC 60332-1-2 / IEC 60332-3-24 ignifuge

KX — IEC 60584-3 (Vert/Blanc)

Positive (+) Vert, Negative (−) Blanc, Gaine extérieure Vert (ou Bleu pour Ex-i)

KX — ANSI MC96.1 (Jaune/Rouge)

Positive (+) Jaune, Negative (−) Rouge, Gaine extérieure Jaune selon ASTM E230

KX-FEP / KX-SWA

+200 °C FEP fluoropolymère pour hot four zones ou SWA armé pour refinery trenches

Données techniques

Valeurs nominales et limites de service

Valeurs types: Valeurs types pour ce type de câble, basés sur IEC 60584-3 / ANSI MC96.1 / ASTM E230. Les valeurs de votre commande sont confirmées dans la fiche technique et le devis.

Électriques

Positive conducteur (+)
Nickel-Chromium (NiCr, ~90 % Ni / 10 % Cr, non-magnetic)
Negative conducteur (−)
Nickel-Aluminium (NiAl, ~95 % Ni / 2 % Mn / 2 % Al, magnetic)
Tolerance Class 1 (IEC 60584-3)
±1.5 °C (±25 µV) sur −25 °C à +200 °C junction gamme
Tolerance Class 2 (IEC 60584-3)
±2.5 °C (±40 µV) sur −25 °C à +200 °C junction gamme
Nominal Seebeck coefficient
≈ 40.6 µV/°C (0 à +100 °C) · boucle R ≈ 1.00 Ω/m à 1.0 mm²

Thermiques

Thermoelectric calibration gamme
−25 °C à +200 °C (véritable extension qualité KX)
Isolation caractéristique assignée (par gaine Type)
−25…+105 °C (HR-PVC) · −40…+90 °C (XLPE/LSZH) · −60…+200 °C (FEP)

Mécaniques

Toronnage du conducteur
0.5 mm² (7/0.30) · 1.0 mm² (7/0.43) · 1.5 mm² (7/0.53) ou massif
Rayon minimal de courbure
7.5 × OD (non armé) · 10 × OD (SWA armé)

Résistance

Non-propagation de la flamme
IEC 60332-1-2 & IEC 60332-3-24 Cat. C
Chemical & huile résistance
EN 50290-2-22 résistant à l'huile PVC ou chimiquement inert FEP

Normes de référence

Thermocouple câble standard
IEC 60584-3, ANSI/ISA MC96.1 (ASTM E230) & DIN 43722
Câble construction standard
BS EN 50288-7 / BS 5308

Identification

IEC 60584-3 code couleur
(+) Vert · (−) Blanc · Gaine extérieure: Vert (ou Bleu Ex-i)
ANSI MC96.1 code couleur
(+) Jaune · (−) Rouge · Gaine extérieure: Jaune
Code tarifaire douanier (HS)
8544.49

Dimensions

16 standard KX / Type K extension thermocouple câble sections

Disponible dans unique-paire et multi-paire (1P à 24P) PVC, XLPE/LSZH, FEP (+200 °C) et SWA armé exécutions.

Dimensions, construction & weights
Désignation de commandeConfigurationIsolation / GaineTemp.. gammeØ ext. ≈
mm
Masse ≈
kg/km
Min. courbure R
fixe mm
Demande
KX Résistant à la chaleur PVC / PVC Blindé (−25…+105 °C)
KX-PVC-OS 1×2×0.51×2×0.5 mm² (7/0.30)PVC / PVC (OS)−25…+105 °C5.64442
KX-PVC-PiMF 2×2×0.52×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)−25…+105 °C8.68464
KX-PVC-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)−25…+105 °C10.814281
KX-PVC-PiMF 8×2×0.58×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)−25…+105 °C14.1246106
KX-PVC-PiMF 12×2×0.512×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)−25…+105 °C16.9348127
KX-PVC-OS 1×2×1.01×2×1.0 mm² (7/0.43)PVC / PVC (OS)−25…+105 °C6.76850
KX-PVC-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)−25…+105 °C12.821296
KX-PVC-OS 1×2×1.51×2×1.5 mm² (7/0.53)PVC / PVC (OS)−25…+105 °C7.59256
KX-PVC-PiMF 4×2×1.54×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)−25…+105 °C14.3286107
KX-PVC-PiMF 12×2×1.512×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)−25…+105 °C22.6710170
KX Haute température FEP / FEP Blindé (−60…+200 °C)
KX-FEP-OS 1×2×0.51×2×0.5 mm² (7/0.30)FEP / FEP (OS)−60…+200 °C4.63834
KX-FEP-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)FEP / FEP (PiMF+OS)−60…+200 °C9.212869
KX-FEP-OS 1×2×1.01×2×1.0 mm² (7/0.43)FEP / FEP (OS)−60…+200 °C5.65842
KX XLPE / LSZH / SWA Armé Direct-Burial (−40…+90 °C)
KX-XLPE-SWA 1×2×1.51×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH−40…+90 °C12.1298121
KX-XLPE-SWA 4×2×1.54×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH−40…+90 °C19.8745198
KX-XLPE-SWA 8×2×1.58×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH−40…+90 °C25.01,180250
  • Valeurs types pour ce type de câble ; les dimensions et masses de votre commande sont confirmées dans le devis.
  • Spécifier 'IEC' (Vert/Blanc) ou 'ANSI' (Jaune/Rouge) code couleur et Class 1 ou Class 2 EMF tolerance lorsque ordering.

Qualité et homologations

Essais et contrôle

Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.

  1. ConducteurToronnage classe 5
  2. Essai à l’étincelle100 % en ligne
  3. AssemblageConducteurs, terre, bourrages
  4. GainageIntérieure, tresse / écran, extérieure
  5. Essais électriquesTension CA, résistance
  6. DimensionsDE, épaisseur de paroi
  7. Documents de contrôle et expéditionTouret et expédition
Essais et contrôleValeur d’essai / référenceFréquence
Essais individuels
Thermoelectric EMF calibration essai (IEC 60584-3)EMF deviation au sein de Class 1 (±1.5 °C / ±25 µV) à +100 °C / +200 °C reference pointsChaque alliage fusion & production batch
1500 V / 2000 V AC diélectrique essai & continuité contrôle1 min AC withstand essai sans breakdown; polarity verifiedChaque fabriqué tambour

Certificat de contrôle

Délivré avec chaque touret, indiquant les résultats des essais individuels pour cette longueur.

Homologations du produit

IEC 60584-3 Class 1 & Class 2 CertifiedANSI/ISA MC96.1 & ASTM E230 CompliantCE, RoHS 2 (2011/65/EU) & REACH

Certificats de l’entreprise

ISO 9001ISO 14001ISO 45001Homologation VDEUL / cULCE · LVD / EMC

Marquage et livraison

Commande et livraison

Marquage de la gaine

TEBAOFLEX KX TYPE K EXTENSION <size> IEC 60584-3 CLASS 1 CE
Conditionnement de livraison
Non-returnable fumigated wooden tambours
Standard pas
500 m · 1000 m standard tambours (coupure pas sur demande)
Commande minimale
500 m (stock sections) · 1000 m (sur mesure)
Délai de livraison
2–4 weeks ex-travaille
Incoterms
EXW, FCA, FOB, CIF, DAP

Documents techniques

Téléchargements

Révision
2026-10-20
Mise à jour
2026-10-20

FAQ

Les premières questions des ingénieurs

Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.

What est le difference entre KX (extension câble) et KCA / KCB (compensating câbles)?
KX est un véritable extension câble whose conducteurs sont fabriqué du exact même Nickel-Chromium (+ NiCr) et Nickel-Aluminium (− NiAl) alloys comme le Type K thermocouple itself, achieving Class 1 (±1.5 °C) accuracy de −25 °C à +200 °C . KCA (Fe/CuNi, 0 à +200 °C) et KCB (Cu/CuNi, 0 à +100 °C) utilisation lower-cost substitute alloys et sont uniquement assigné à Class 2 (±2.5 °C).
How CAN un champ technician quickly distinguish le positive (+) et negative (−) KX conducteurs if le isolation est stripped back?
Dans addition à le code couleur (IEC: + Vert / − Blanc; ANSI: + Jaune / − Rouge), le negative NiAl conducteur est noticeably magnetic et will attract un petit pocket électroaimant, whereas le positive NiCr conducteur est non-magnetic.
Why must Type K thermocouples never be étendue utilisant standard cuivre instrumentation câble (RE-2Y(st)Y)?
Connecting cuivre fils à un NiCr/NiAl thermocouple terminal tête creates un parasitic à froid junction directly à l'intérieur du hot four tête coffret. Any température difference entre le four tête coffret et le commande room à froid-junction sensor will appear directly comme un 1:1 measurement error (often 30 °C à 150 °C off).
How should le écran et drain fil de KX / Type K extension be earthed dans instrumentation et Ex-i boucles?
À empêcher circulating 50/60 Hz terre-boucle courants de coupling en millivolt ou 4–20 mA signaux, le Al/ PET écran et cuivre étamé drain fil de KX / Type K extension should be lié à le propre instrumentation terre bar à un extrémité uniquement (typically dans le commande/marshalling cabinet) et isolé contre chassis contact à le champ transmitter ou junction coffret, dans accordance avec IEC 60079-14 et EN 50288-7 .

Demander un devis

Obtenez un devis technique pour KX / Type K extension

Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.

01Dimensions sélectionnées

Utilisez + Ajouter à côté d’une dimension ou configuration.

02Enrouleur et mouvement

Ajoutez ici vos conditions de service pour les inclure dans votre demande.

03Message pour nos ingénieurs

KX / Type K extension Thermocouple Câble

Dimensions sélectionnées:


Enrouleur et mouvement:
- Type d’enrouleur: 
- Diamètre du noyau du tambour (mm): 
- Longueur de câble sur tambour (m): 
- Vitesse de déplacement (m/min): 
- Accélération maximale: 
- Cycles par heure: 
- Longueur et quantité: 
- Température ambiante: 
- Exposition (extérieur, eau, huile, abrasion): 
- Pays de destination: 
- Équipement et conditions de service: 
Envoyer par WhatsApp

Fiche techniqueDemander un devis