IEC 60584-3 Type NC compensating cableIEC 60584-3 Type NC (NCA/NCB)Cu (+) / CuNi (−) CompensatingClass 2 (±2.5 °C) · Bajo Bucle R

Modelo NC Type N Thermocouple Compensating CableCu / CuNi compensating cable (NCA / NCB) para Type N (Nicrosil-Nisil) thermocouples

Cu / CuNi compensating cable (NCA / NCB) para Type N (Nicrosil-Nisil) thermocouples

Diseño de baja CEM
Pantalla CEM
Retardante de llama
Resistente al aceite
Designación de pedido
NCB-PVC-PiMF 4×2×1.5
Ø ext. ≈
14.3 mm
Total peso ≈
286 kg/km
Min. curvatura R (fijo)
107 mm
Configuración
4×2×1.5 mm² (7/0.53)
Todas las medidas (14)
Respuesta de ingeniería en 2 horas laborablesTambores de exportación cortados a medidaCertificado EN 10204 3.1 por tambor
Compensates para
Type N (NiCrSi)
Nicrosil-Nisil thermocouples
Aleación par
Cu (+) / CuNi
Cobre (+) / N-calibrated CuNi (−)
Junction ranges
0…+100 / +200 °C
NCB (0…+100 °C) · NCA (0…+200 °C)
EMF tolerance
Class 2: ±2.5 °C
±65 µV (measured a 900 °C)
Bucle resistencia
≈ 0.36 Ω/m/par
a 1.0 mm² (vs 1.35 Ω/m en NX)
IEC código de colores
+ Pink / − Blanco
Pink cubierta exterior (o Ex-i Azul)

Valores típicos para este tipo de cable, basados en IEC 60584-3 / BS EN 50288-7 — confirmados en la ficha técnica y oferta de su pedido.

Aplicaciones

¿Es NC adecuado para su máquina?

Bajo-resistencia Type NC (NCA 0…+200 °C y NCB 0…+100 °C) thermocouple compensating cable built a IEC 60584-3 con specially alloyed Cobre (+ Cu) y Cobre-Níquel (− CuNi) conductores calibrated a match el ~27.7 µV/°C Type N (Nicrosil-Nisil) EMF slope.

Instalación fija

Adecuado

Disponible en PVC, XLPE/LSZH, +200 °C FEP (NCA) y SWA armado multi-par construcciones.

Pórtico de tuneladora TBM y avance

Adecuado

SWA armado ejecución (NCB-XLPE-SWA) protege subterráneo petrochemical y acero-plant trunks.

Bandejas en plataformas offshore y buques

Adecuado

No-ferrous Cu/CuNi conductores resisten corrosión en humid y coastal proceso plants.

Máquinas habitualesAcero Blast Furnaces, Stoves & Reheat FurnacesEtileno Crackers & Petrochemical HeatersPotencia Generación Boilers & SuperheatersCeramic, Brick & Refractory Túnel KilnsIndustrial Incineration & Flue-Gas Trunks

Construcción

Capa por capa

Mostrado: NCB-PVC -PiMF 4×2×1.0 mm² (IEC 60584-3) con de 7 hilos cableado Cu (+) y N-calibrated CuNi (−) conductores, Pink (+) / Blanco (−) numerados aislamiento, individual & colectiva Al/ PET pantallas y Pink RAL 3015 cubierta exterior.

12345
Esquema sin escala — generado a partir de los datos de capas
#CapaMaterial y referencia
1Matched Type NC (NCA/NCB) compensating conductoresPositive (+): Alto-purity Cobre (Cu) · Negative (−): Tipo-N-calibrated Cobre-Níquel (CuNi ~70/30 aleación), de 7 hilos cableadoMatches el ~27.7 µV/°C Type N slope mientras reducing bucle resistencia por 73 % compared con NX
2Codificados por colores Aislamiento de conductorRetardante de la llama PVC, XLPE o +200 °C FEP (IEC: + Pink / − Blanco; ANSI: + Naranja / − Rojo)Alto aislamiento resistencia y unambiguous polarity identificación
3Individual & colectiva Al/ PET pantallasAluminio/ PET laminated cinta + 0.5 mm² cobre estañado drenaje alambre (OS o PiMF+OS)100 % electrostática apantallamiento
4Opcional SWA armaduraSin armadura o Galvanizado Acero Alambre Armadura (SWA) sobre extruido asientoMecánico aplastamiento protección para multi-par plant trunks
5Cubierta exterior (Pink RAL 3015, Naranja o Ex-i Azul)Retardante de la llama PVC, Baja emisión de humos Libre de halógenos (LSZH), o fluoropolímero FEPIEC 60332-1-2 / IEC 60332-3-24 retardante de la llama

NCB — IEC 60584-3 (0…+100 °C)

Positive (+) Pink, Negative (−) Blanco, Cubierta exterior Pink (RAL 3015) para ambient marshalling cajas

NCA — Ampliada Gama (0…+200 °C)

FEP/HR-PVC aislado NCA compensating aleación par calibrated hasta +200 °C

NCB-XLPE-SWA (Armado Trunk)

XLPE aislado, SWA armado multi-par trunk cable

Datos técnicos

Valores nominales y límites de servicio

Valores típicos: Valores típicos para este tipo de cable, basados en IEC 60584-3 / BS EN 50288-7. Los valores de su pedido se confirman en la ficha técnica y la oferta.

Eléctricos

Compensado thermocouple Tipo
Type N (Nicrosil-Nisil, NiCrSi-NiSi) según IEC 60584-1
Positive conductor (+)
De alta conductividad Cobre (Cu, no-magnetic, ~1.72 µΩ·cm)
Negative conductor (−)
Tipo-N-calibrated Cobre-Níquel (CuNi aleación, no-magnetic, ~34 µΩ·cm)
Tolerance Class 2 (IEC 60584-3)
±2.5 °C (±65 µV) sobre 0…+100 °C (NCB) o 0…+200 °C (NCA)
Bucle resistencia @ 20 °C
≈ 0.72 Ω/m (0.5 mm²) · 0.36 Ω/m (1.0 mm²) · 0.24 Ω/m (1.5 mm²)

Térmicos

Permissible junction temperatura gama
0 °C a +100 °C (Type NCB) · 0 °C a +200 °C (Type NCA)
Aislamiento capacidad nominal (por cubierta Tipo)
−25…+105 °C (PVC) · −40…+90 °C (XLPE/LSZH) · −60…+200 °C (FEP)

Mecánicos

Cableado del conductor
0.5 mm² (7/0.30) · 1.0 mm² (7/0.43) · 1.5 mm² (7/0.53)
Radio mínimo de curvatura
7.5 × OD (sin armadura) · 10 × OD (SWA armado)

Resistencia

Retardancia de la llama
IEC 60332-1-2 & IEC 60332-3-24 Cat. C
Corrosión resistencia
100 % no-ferrous Cu/CuNi conductores

Normas de referencia

Thermocouple cable estándar
IEC 60584-3 & ANSI/ISA MC96.1
Cable construcción estándar
BS EN 50288-7 / BS 5308

Identificación

IEC 60584-3 código de colores
(+) Pink · (−) Blanco · Cubierta exterior: Pink (o Azul Ex-i)
ANSI MC96.1 código de colores
(+) Naranja · (−) Rojo · Cubierta exterior: Naranja
Partida arancelaria (HS)
8544.49

Dimensiones

14 estándar NC (NCA / NCB) Type N compensating cable tamaños

1 a 24 pares en PVC, +200 °C FEP (NCA) y XLPE/LSZH/SWA armado construcciones.

Dimensions, construcción & weights
Designación de pedidoConfiguraciónAislamiento / CubiertaJunction gamaØ ext. ≈
mm
Peso ≈
kg/km
Min. curvatura R
fijo mm
Consulta
NCB PVC / PVC Apantallado Marshalling Cables (0…+100 °C)
NCB-PVC-OS 1×2×0.51×2×0.5 mm² (7/0.30)PVC / PVC (OS)0…+100 °C5.64442
NCB-PVC-PiMF 2×2×0.52×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C8.68464
NCB-PVC-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C10.814281
NCB-PVC-PiMF 8×2×0.58×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C14.1246106
NCB-PVC-PiMF 12×2×0.512×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C16.9348127
NCB-PVC-OS 1×2×1.01×2×1.0 mm² (7/0.43)PVC / PVC (OS)0…+100 °C6.76850
NCB-PVC-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C12.821296
NCB-PVC-OS 1×2×1.51×2×1.5 mm² (7/0.53)PVC / PVC (OS)0…+100 °C7.59256
NCB-PVC-PiMF 4×2×1.54×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C14.3286107
NCA FEP / FEP Ampliada-Gama Compensating Cables (0…+200 °C)
NCA-FEP-OS 1×2×1.01×2×1.0 mm² (7/0.43)FEP / FEP (OS)0…+200 °C5.65842
NCA-FEP-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)FEP / FEP (PiMF+OS)0…+200 °C11.218884
NCB XLPE / LSZH / SWA Armado Directo-Burial Trunks (0…+90 °C)
NCB-XLPE-SWA 1×2×1.51×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C12.1298121
NCB-XLPE-SWA 4×2×1.54×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C19.8745198
NCB-XLPE-SWA 8×2×1.58×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C25.41,210254
  • Valores típicos para este tipo de cable; las dimensiones y pesos de su pedido se confirman en la oferta.
  • No interchange KCB y NCB: although tanto uso Cu/CuNi alloys, NCB uses un different CuNi composition matched a ~27.7 µV/°C instead de ~40.6 µV/°C.

Calidad y homologaciones

Ensayos e inspección

Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.

  1. ConductorCuerda clase 5
  2. Ensayo de chispa100 % en línea
  3. CableadoConductores, tierra, rellenos
  4. Extrusión de cubiertaInterior, trenza / pantalla, exterior
  5. Ensayos eléctricosTensión CA, resistencia
  6. DimensionesDE, espesor de pared
  7. Documentos de inspección y expediciónTambor y expedición
Ensayos e inspecciónValor de ensayo / referenciaFrecuencia
Ensayos de rutina
Thermoelectric EMF calibration ensayo (IEC 60584-3 Class 2)EMF deviation dentro de ±2.5 °C (±65 µV) sobre 0…+100 °C (NCB) o 0…+200 °C (NCA)Cada aleación batch
1500 V / 2000 V AC dieléctrico & continuidad ensayo1 min AC withstand ensayo sin breakdownCada fabricado tambor

Certificado de inspección

Emitido con cada tambor, con los resultados de los ensayos de rutina de esa longitud.

Homologaciones del producto

IEC 60584-3 Class 2 (NCA / NCB) CertifiedBS EN 50288-7 & BS 5308 CompliantCE, RoHS 2 (2011/65/EU) & REACH

Certificados de la empresa

ISO 9001ISO 14001ISO 45001Homologación VDEUL / cULCE · LVD / EMC

Marcado y suministro

Pedido y entrega

Marcado de la cubierta

TEBAOFLEX NC TYPE N COMPENSATING <size> IEC 60584-3 CLASS 2 CE
Forma de suministro
No-returnable fumigated wooden tambores
Estándar pasos
500 m · 1000 m estándar tambores (corte pasos bajo pedido)
Pedido mínimo
500 m (stock tamaños) · 1000 m (a medida)
Plazo de entrega
2–4 weeks ex-trabaja
Incoterms
EXW, FCA, FOB, CIF, DAP

Documentación técnica

Descargas

Revisión
2026-10-20
Actualizado
2026-10-20

Preguntas frecuentes

Las primeras preguntas de ingeniería

¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.

CAN KCB (Cu/CuNi para Type K) be used instead de NC (Cu/CuNi para Type N)?
Sin. Although tanto KCB y NC uso Cobre (+) y Cobre-Níquel (−) conductores, el Níquel percentage en el negative leg está formulated differently: KCB generates ~4.10 mV a +100 °C a match Type K, whereas NC generates ~2.77 mV a +100 °C a match Type N . Mixing ellos causes un ~13 µV/°C en frío-junction error.
What está el difference entre NCA y NCB bajo IEC 60584-3?
NCB está calibrated para transition junction temperatures de 0 °C a +100 °C, whereas NCA está calibrated sobre un ampliada 0 °C a +200 °C junction gama. Tanto hold un Class 2 tolerance de ±2.5 °C (±65 µV).
Why does NC have 73 % lower bucle resistencia que verdadera NX extension cable?
Verdadera NX uses Nicrosil (98 µΩ·cm) y Nisil (37 µΩ·cm), giving ~1.35 Ω/m según 1.0 mm² par. NC reemplaza el positive leg con puro Cobre (1.72 µΩ·cm) y el negative leg con bajo-níquel CuNi (~34 µΩ·cm), dropping bucle resistencia a ~0.36 Ω/m.
How should el pantalla y drenaje alambre de NC be earthed en instrumentación y Ex-i lazos?
A evitar circulating 50/60 Hz tierra-bucle corrientes de coupling en millivolt o 4–20 mA señales, el Al/ PET pantalla y cobre estañado drenaje alambre de NC should be adherido al limpio instrumentación tierra bar a un extremo solo (typically en el control/marshalling cabinet) y aislado contra chassis contacto al campo transmitter o junction caja, en accordance con IEC 60079-14 y EN 50288-7 .

Solicitar presupuesto

Solicite una oferta técnica para NC

La selección y los datos de aplicación se copian al formulario de consulta inferior.

01Medidas seleccionadas

Use + Añadir junto a una medida o configuración.

02Tambor y movimiento

Añada aquí las condiciones de servicio para incluirlas en su consulta.

03Mensaje para nuestros ingenieros

Modelo NC Type N Thermocouple Compensating Cable

Medidas seleccionadas:


Tambor y movimiento:
- Tipo de tambor: 
- Diámetro del núcleo del tambor (mm): 
- Longitud de cable en tambor (m): 
- Velocidad de desplazamiento (m/min): 
- Aceleración máxima: 
- Ciclos por hora: 
- Longitud y cantidad: 
- Temperatura ambiente: 
- Exposición (exterior, agua, aceite, abrasión): 
- País de destino: 
- Equipo y condiciones de servicio: 
Enviar por WhatsApp

Ficha técnicaSolicitar presupuesto