IEC 60584-3 Type NC compensating câbleIEC 60584-3 Type NC (NCA/NCB)Cu (+) / CuNi (−) CompensatingClass 2 (±2.5 °C) · Faible Boucle R

NC Type N Thermocouple Compensating CâbleCu / CuNi compensating câble (NCA / NCB) pour Type N (Nicrosil-Nisil) thermocouples

Cu / CuNi compensating câble (NCA / NCB) pour Type N (Nicrosil-Nisil) thermocouples

Conception faible CEM
Écran CEM
Ignifuge
Résistant à l’huile
Désignation de commande
NCB-PVC-PiMF 4×2×1.5
Ø ext. ≈
14.3 mm
Total masse ≈
286 kg/km
Min. courbure R (fixe)
107 mm
Configuration
4×2×1.5 mm² (7/0.53)
Toutes les dimensions (14)
Réponse technique sous 2 heures ouvréesTourets d’exportation coupés à la longueurCertificat EN 10204 3.1 par touret
Compensates pour
Type N (NiCrSi)
Nicrosil-Nisil thermocouples
Alliage paire
Cu (+) / CuNi
Cuivre (+) / N-calibrated CuNi (−)
Junction ranges
0…+100 / +200 °C
NCB (0…+100 °C) · NCA (0…+200 °C)
EMF tolerance
Class 2: ±2.5 °C
±65 µV (measured à 900 °C)
Boucle résistance
≈ 0.36 Ω/m/paire
à 1.0 mm² (vs 1.35 Ω/m sur NX)
IEC code couleur
+ Pink / − Blanc
Pink gaine extérieure (ou Ex-i Bleu)

Valeurs types pour ce type de câble, basés sur IEC 60584-3 / BS EN 50288-7 — confirmées dans la fiche technique et le devis de votre commande.

Applications

NC convient-il à votre machine ?

Faible-résistance Type NC (NCA 0…+200 °C et NCB 0…+100 °C) thermocouple compensating câble built à IEC 60584-3 avec specially alloyed Cuivre (+ Cu) et Cuivre-Nickel (− CuNi) conducteurs calibrated à match le ~27.7 µV/°C Type N (Nicrosil-Nisil) EMF slope.

Installation fixe

Adapté

Disponible dans PVC, XLPE/LSZH, +200 °C FEP (NCA) et SWA armé multi-paire constructions.

Portique de tunnelier TBM et avancement

Adapté

SWA armé exécution (NCB-XLPE-SWA) protège souterrain petrochemical et acier-plant trunks.

Chemins de câbles offshore et navires

Adapté

Non-ferrous Cu/CuNi conducteurs résistent à corrosion dans humid et coastal procédé plants.

Machines typesAcier Blast Furnaces, Stoves & Reheat FurnacesÉthylène Crackers & Petrochemical HeatersPuissance Génération Boilers & SuperheatersCeramic, Brick & Refractory Tunnel KilnsIndustriel Incineration & Flue-Gaz Trunks

Construction

Couche par couche

Illustré: NCB-PVC -PiMF 4×2×1.0 mm² (IEC 60584-3) avec à 7 fils toronné Cu (+) et N-calibrated CuNi (−) conducteurs, Pink (+) / Blanc (−) numérotés isolation, individuel & collectif Al/ PET écrans et Pink RAL 3015 gaine extérieure.

12345
Schéma sans échelle — généré à partir des données des couches
#CoucheMatériau et référence
1Matched Type NC (NCA/NCB) compensating conducteursPositive (+): Élevé-purity Cuivre (Cu) · Negative (−): Type-N-calibrated Cuivre-Nickel (CuNi ~70/30 alliage), à 7 fils toronnéMatches le ~27.7 µV/°C Type N slope tout en reducing boucle résistance par 73 % compared avec NX
2Repérés par couleurs Isolation de conducteurIgnifuge PVC, XLPE ou +200 °C FEP (IEC: + Pink / − Blanc; ANSI: + Orange / − Rouge)Élevé isolation résistance et unambiguous polarity identification
3Individuel & collectif Al/ PET écransAluminium/ PET laminated ruban + 0.5 mm² cuivre étamé drain fil (OS ou PiMF+OS)100 % électrostatique blindage
4En option SWA armureNon armé ou Galvanisé Acier Fil Armure (SWA) sur extrudé bourrageMécanique écrasement protection pour multi-paire plant trunks
5Gaine extérieure (Pink RAL 3015, Orange ou Ex-i Bleu)Ignifuge PVC, Faible émission de fumée Sans halogène (LSZH), ou fluoropolymère FEPIEC 60332-1-2 / IEC 60332-3-24 ignifuge

NCB — IEC 60584-3 (0…+100 °C)

Positive (+) Pink, Negative (−) Blanc, Gaine extérieure Pink (RAL 3015) pour ambient marshalling coffrets

NCA — Étendue Gamme (0…+200 °C)

FEP/HR-PVC isolé NCA compensating alliage paire calibrated jusqu'à +200 °C

NCB-XLPE-SWA (Armé Trunk)

XLPE isolé, SWA armé multi-paire trunk câble

Données techniques

Valeurs nominales et limites de service

Valeurs types: Valeurs types pour ce type de câble, basés sur IEC 60584-3 / BS EN 50288-7. Les valeurs de votre commande sont confirmées dans la fiche technique et le devis.

Électriques

Compensé thermocouple Type
Type N (Nicrosil-Nisil, NiCrSi-NiSi) selon IEC 60584-1
Positive conducteur (+)
Haute conductivité Cuivre (Cu, non-magnetic, ~1.72 µΩ·cm)
Negative conducteur (−)
Type-N-calibrated Cuivre-Nickel (CuNi alliage, non-magnetic, ~34 µΩ·cm)
Tolerance Class 2 (IEC 60584-3)
±2.5 °C (±65 µV) sur 0…+100 °C (NCB) ou 0…+200 °C (NCA)
Boucle résistance @ 20 °C
≈ 0.72 Ω/m (0.5 mm²) · 0.36 Ω/m (1.0 mm²) · 0.24 Ω/m (1.5 mm²)

Thermiques

Permissible junction température gamme
0 °C à +100 °C (Type NCB) · 0 °C à +200 °C (Type NCA)
Isolation caractéristique assignée (par gaine Type)
−25…+105 °C (PVC) · −40…+90 °C (XLPE/LSZH) · −60…+200 °C (FEP)

Mécaniques

Toronnage du conducteur
0.5 mm² (7/0.30) · 1.0 mm² (7/0.43) · 1.5 mm² (7/0.53)
Rayon minimal de courbure
7.5 × OD (non armé) · 10 × OD (SWA armé)

Résistance

Non-propagation de la flamme
IEC 60332-1-2 & IEC 60332-3-24 Cat. C
Corrosion résistance
100 % non-ferrous Cu/CuNi conducteurs

Normes de référence

Thermocouple câble standard
IEC 60584-3 & ANSI/ISA MC96.1
Câble construction standard
BS EN 50288-7 / BS 5308

Identification

IEC 60584-3 code couleur
(+) Pink · (−) Blanc · Gaine extérieure: Pink (ou Bleu Ex-i)
ANSI MC96.1 code couleur
(+) Orange · (−) Rouge · Gaine extérieure: Orange
Code tarifaire douanier (HS)
8544.49

Dimensions

14 standard NC (NCA / NCB) Type N compensating câble sections

1 à 24 paires dans PVC, +200 °C FEP (NCA) et XLPE/LSZH/SWA armé constructions.

Dimensions, construction & weights
Désignation de commandeConfigurationIsolation / GaineJunction gammeØ ext. ≈
mm
Masse ≈
kg/km
Min. courbure R
fixe mm
Demande
NCB PVC / PVC Blindé Marshalling Câbles (0…+100 °C)
NCB-PVC-OS 1×2×0.51×2×0.5 mm² (7/0.30)PVC / PVC (OS)0…+100 °C5.64442
NCB-PVC-PiMF 2×2×0.52×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C8.68464
NCB-PVC-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C10.814281
NCB-PVC-PiMF 8×2×0.58×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C14.1246106
NCB-PVC-PiMF 12×2×0.512×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C16.9348127
NCB-PVC-OS 1×2×1.01×2×1.0 mm² (7/0.43)PVC / PVC (OS)0…+100 °C6.76850
NCB-PVC-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C12.821296
NCB-PVC-OS 1×2×1.51×2×1.5 mm² (7/0.53)PVC / PVC (OS)0…+100 °C7.59256
NCB-PVC-PiMF 4×2×1.54×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C14.3286107
NCA FEP / FEP Étendue-Gamme Compensating Câbles (0…+200 °C)
NCA-FEP-OS 1×2×1.01×2×1.0 mm² (7/0.43)FEP / FEP (OS)0…+200 °C5.65842
NCA-FEP-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)FEP / FEP (PiMF+OS)0…+200 °C11.218884
NCB XLPE / LSZH / SWA Armé Direct-Burial Trunks (0…+90 °C)
NCB-XLPE-SWA 1×2×1.51×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C12.1298121
NCB-XLPE-SWA 4×2×1.54×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C19.8745198
NCB-XLPE-SWA 8×2×1.58×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C25.41,210254
  • Valeurs types pour ce type de câble ; les dimensions et masses de votre commande sont confirmées dans le devis.
  • Non interchange KCB et NCB: although à la fois utilisation Cu/CuNi alloys, NCB uses un different CuNi composition matched à ~27.7 µV/°C instead de ~40.6 µV/°C.

Qualité et homologations

Essais et contrôle

Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.

  1. ConducteurToronnage classe 5
  2. Essai à l’étincelle100 % en ligne
  3. AssemblageConducteurs, terre, bourrages
  4. GainageIntérieure, tresse / écran, extérieure
  5. Essais électriquesTension CA, résistance
  6. DimensionsDE, épaisseur de paroi
  7. Documents de contrôle et expéditionTouret et expédition
Essais et contrôleValeur d’essai / référenceFréquence
Essais individuels
Thermoelectric EMF calibration essai (IEC 60584-3 Class 2)EMF deviation au sein de ±2.5 °C (±65 µV) sur 0…+100 °C (NCB) ou 0…+200 °C (NCA)Chaque alliage batch
1500 V / 2000 V AC diélectrique & continuité essai1 min AC withstand essai sans breakdownChaque fabriqué tambour

Certificat de contrôle

Délivré avec chaque touret, indiquant les résultats des essais individuels pour cette longueur.

Homologations du produit

IEC 60584-3 Class 2 (NCA / NCB) CertifiedBS EN 50288-7 & BS 5308 CompliantCE, RoHS 2 (2011/65/EU) & REACH

Certificats de l’entreprise

ISO 9001ISO 14001ISO 45001Homologation VDEUL / cULCE · LVD / EMC

Marquage et livraison

Commande et livraison

Marquage de la gaine

TEBAOFLEX NC TYPE N COMPENSATING <size> IEC 60584-3 CLASS 2 CE
Conditionnement de livraison
Non-returnable fumigated wooden tambours
Standard pas
500 m · 1000 m standard tambours (coupure pas sur demande)
Commande minimale
500 m (stock sections) · 1000 m (sur mesure)
Délai de livraison
2–4 weeks ex-travaille
Incoterms
EXW, FCA, FOB, CIF, DAP

Documents techniques

Téléchargements

Révision
2026-10-20
Mise à jour
2026-10-20

FAQ

Les premières questions des ingénieurs

Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.

CAN KCB (Cu/CuNi pour Type K) be used instead de NC (Cu/CuNi pour Type N)?
Sans. Although à la fois KCB et NC utilisation Cuivre (+) et Cuivre-Nickel (−) conducteurs, le Nickel percentage dans le negative leg est formulated differently: KCB generates ~4.10 mV à +100 °C à match Type K, whereas NC generates ~2.77 mV à +100 °C à match Type N . Mixing eux causes un ~13 µV/°C à froid-junction error.
What est le difference entre NCA et NCB sous IEC 60584-3?
NCB est calibrated pour transition junction temperatures de 0 °C à +100 °C, whereas NCA est calibrated sur un étendue 0 °C à +200 °C junction gamme. À la fois hold un Class 2 tolerance de ±2.5 °C (±65 µV).
Why does NC have 73 % lower boucle résistance que véritable NX extension câble?
Véritable NX uses Nicrosil (98 µΩ·cm) et Nisil (37 µΩ·cm), giving ~1.35 Ω/m selon 1.0 mm² paire. NC remplace le positive leg avec pur Cuivre (1.72 µΩ·cm) et le negative leg avec faible-nickel CuNi (~34 µΩ·cm), dropping boucle résistance à ~0.36 Ω/m.
How should le écran et drain fil de NC be earthed dans instrumentation et Ex-i boucles?
À empêcher circulating 50/60 Hz terre-boucle courants de coupling en millivolt ou 4–20 mA signaux, le Al/ PET écran et cuivre étamé drain fil de NC should be lié à le propre instrumentation terre bar à un extrémité uniquement (typically dans le commande/marshalling cabinet) et isolé contre chassis contact à le champ transmitter ou junction coffret, dans accordance avec IEC 60079-14 et EN 50288-7 .

Demander un devis

Obtenez un devis technique pour NC

Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.

01Dimensions sélectionnées

Utilisez + Ajouter à côté d’une dimension ou configuration.

02Enrouleur et mouvement

Ajoutez ici vos conditions de service pour les inclure dans votre demande.

03Message pour nos ingénieurs

NC Type N Thermocouple Compensating Câble

Dimensions sélectionnées:


Enrouleur et mouvement:
- Type d’enrouleur: 
- Diamètre du noyau du tambour (mm): 
- Longueur de câble sur tambour (m): 
- Vitesse de déplacement (m/min): 
- Accélération maximale: 
- Cycles par heure: 
- Longueur et quantité: 
- Température ambiante: 
- Exposition (extérieur, eau, huile, abrasion): 
- Pays de destination: 
- Équipement et conditions de service: 
Envoyer par WhatsApp

Fiche techniqueDemander un devis