SAE J1128 Norteamericanos Automotive Primario Hilos60 V DC / 25 V ACSAE J1128 De pared delgada PVC24 a 8 AWG

TWP De pared delgada Automotive Alambre60 V DC / 25 V AC SAE J1128 de pared delgada termoplástico PVC automotive alambre (24–8 AWG)

60 V DC / 25 V AC SAE J1128 de pared delgada termoplástico PVC automotive alambre (24–8 AWG)

SAE J1128 Fluid Resistente
Auto-Extinguishing PVC
SAE J1128 Type TWP
Designación de pedido
TWP 18 AWG (0.8 mm²)
Ø ext. máx.
2.20 mm
Masa de cobre
8.9 kg/km
Total masa ≈
12.1 kg/km
Radio mín. curvatura
8.8 mm
Todas las medidas (12)
Respuesta de ingeniería en 2 horas laborablesTambores de exportación cortados a medidaCertificado EN 10204 3.1 por tambor
Tensión nominal
60 V DC / 25 V un
SAE J1128 superficie vehículo LV
Clase térmica
-40 a +85 / +105
SAE Class A (85 °C) / Class B (105 °C)
Calibre gama
24 a 8 AWG
0.22 a 8.0 mm² métrico equivalente
Pared perfil
De pared delgada (0.40m
0.40 mm nominal pared (24–14 AWG)
Conductor
Cableado Cu
ASTM B3 concéntrico cobre desnudo
Radio mínimo de curvatura
4 × alambre OD
Compacto instrument & door looms

Valores típicos para este tipo de cable, basados en SAE J1128 / ISO 6722-1 Class A /B — confirmados en la ficha técnica y oferta de su pedido.

Aplicaciones

¿Es TWP adecuado para su máquina?

Type TWP (De pared delgada Termoplástico) está un reducido-diámetro 60 V DC (25 V AC) SAE J1128 primario alambre featuring un 0.40 mm (0.016 en) nominal PVC pared en 24–14 AWG tamaños. It cuts harness haz volume por hasta 25 % compared con regular-pared GPT mientras operating fro

Instalación fija

Adecuado

Alto-density harness tendido hasta door grommets, un/B pillars y behind instrument panels.

Cableado de celdas y armarios de control

Adecuado

Delgado 0.40 mm pared fits miniature métrico/USCAR sealed y unsealed multi-pin conector cavities.

Arrastre y remolque

No adecuado

Unipolar harness alambre must be encintado o loomed dentro de un de protección harness conjunto.

FLRYY Multipolar truck cable

Horno, estufa y zona de alta temperatura

No adecuado

Cable de salida-libre termoplástico PVC está limited a +85 / +105 °C; especifique TXL para +125 °C engine bays.

TXL +125 °C de pared delgada XLPE
Máquinas habitualesAutomotive cockpit & dash harnessesBody & door cableado módulosCommercial truck & bus cabinsAgricultural maquinaria cabsMarino instrument panels

Construcción

Capa por capa

ASTM B3 concéntrico cableado recocido desnudo conductor de cobre + de pared delgada (0.40 mm en 24–14 AWG) cable de salida-libre termoplástico PVC aislamiento + liso color/franja exterior piel.

123
Esquema sin escala — generado a partir de los datos de capas
#CapaMaterial y referencia
1Cableado desnudo conductor de cobreConcéntrico cableado recocido cobre desnudo según ASTM B3 / SAE J1128 (7 o 19 hilos)ASTM B3
2De pared delgada termoplástico PVCDe alta rigidez dieléctrica-resistencia cable de salida-libre polyvinyl chloride (PVC) compuesto (0.40 mm nominal pared en 24–14 AWG)SAE J1128
3Liso codificados por colores superficie pielIntegral de baja fricción extruido exterior piel con opcional spiral o longitudinal hilo guía de color franjaSAE J1128

SAE J1128 TWP (85 °C Class A)

Estándar SAE J1128 de pared delgada PVC primario alambre para passenger compartimento y body harnesses.

TWP-105 (105 °C Class B)

Calor-stabilised +105 °C de pared delgada PVC compuesto matching Chrysler MS-8900 y Ford ESB-M1L120-A .

Datos técnicos

Valores nominales y límites de servicio

Valores típicos: Valores típicos para este tipo de cable, basados en SAE J1128 / ISO 6722-1 Class A /B. Los valores de su pedido se confirman en la ficha técnica y la oferta.

Eléctricos

Tensión nominal capacidad nominal
≤60 V DC / ≤25 V AC
Húmedo dieléctrico withstand
1.0 kV AC rms para 1 minute after 4 h saltwater inmersión
En-line spark ensayo
1.5 kV a 3.0 kV AC rms

Térmicos

Continuo temperatura capacidad nominal
-40 °C a +85 °C (Class A) / +105 °C (Class B opción)
En frío curvatura performance
-40 °C para 4 hours alrededor de especificado mandrel

Mecánicos

Nom. espesor de pared (24–14 AWG)
0.40 mm (0.016 en)
Nom. espesor de pared (12 / 10 / 8 AWG)
0.46 mm (12 AWG) · 0.56 mm (10 AWG) · 0.71 mm (8 AWG)
Sandpaper & scrape abrasión
Meets SAE J1128 de pared delgada abrasión resistencia

Resistencia

Retardancia de la llama
Auto-extinguishing dentro de 70 s según SAE J1128 45° burn ensayo
Automotive fluid resistencia
Resists motor aceite, fuel, coolant, brake fluid y battery electrolyte

Normas de referencia

Governing estándar
SAE J1128 Type TWP
OEM specifications
Chrysler MS-8900 & Ford ESB-M1L120-A

Identificación

Color codificación
Sólido base color con opcional hilo guía de color franja
Embalaje
De alta velocidad payoff spools o barrel packs

Dimensiones

12 estándar tamaños (TWP)

Nominal dimensions, espesor de pared, cobre masa y eléctrico parameters para TWP según SAE J1128 / ISO 6722-1 Class A /B.

Dimensions & masses
DesignaciónAWG (Métrico mm²)Hilos / Pared mmØ ext. máx.
mm
Cobre
kg/km
Total masa ≈
kg/km
Radio mín. curvatura
mm
Consulta
TWP tamaño gama
TWP 24 AWG (0.22 mm²)24 AWG (0.22 mm²)7/32 · 0.40 mm1.552.04.16.2
TWP 22 AWG (0.35 mm²)22 AWG (0.35 mm²)7/30 · 0.40 mm1.703.15.56.8
TWP 20 AWG (0.5 mm²)20 AWG (0.5 mm²)7/28 · 0.40 mm1.954.97.67.8
TWP 18 AWG (0.8 mm²)18 AWG (0.8 mm²)19/30 · 0.40 mm2.208.912.18.8
TWP 16 AWG (1.0 mm²)16 AWG (1.0 mm²)19/29 · 0.40 mm2.4011.214.89.6
TWP 14 AWG (2.0 mm²)14 AWG (2.0 mm²)19/27 · 0.40 mm2.9017.822.311.6
TWP 12 AWG (3.0 mm²)12 AWG (3.0 mm²)19/25 · 0.46 mm3.5028.234.214.0
TWP 10 AWG (5.0 mm²)10 AWG (5.0 mm²)19/23 · 0.56 mm4.3045.053.517.2
TWP 8 AWG (8.0 mm²)8 AWG (8.0 mm²)19/21 · 0.71 mm5.4571.584.521.8
TWP 18 AWG (16/30)18 AWG (16/30)16/30 · 0.40 mm2.157.610.88.6
TWP 16 AWG (26/30)16 AWG (26/30)26/30 · 0.40 mm2.4512.115.89.8
TWP 14 AWG (41/30)14 AWG (41/30)41/30 · 0.40 mm2.9519.123.811.8
  • Valores típicos para este tipo de cable; las dimensiones y pesos de su pedido se confirman en la oferta.
  • Dimensions y máximo general diameters conform a SAE J1128 / ISO 6722-1 Class A /B.

Calidad y homologaciones

Ensayos e inspección

Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.

  1. ConductorCuerda clase 5
  2. Ensayo de chispa100 % en línea
  3. CableadoConductores, tierra, rellenos
  4. Extrusión de cubiertaInterior, trenza / pantalla, exterior
  5. Ensayos eléctricosTensión CA, resistencia
  6. DimensionesDE, espesor de pared
  7. Documentos de inspección y expediciónTambor y expedición
Ensayos e inspecciónValor de ensayo / referenciaFrecuencia
Ensayos de rutina
AC spark ensayo & conductor DC resistencia supervisión100 % spark-ensayado; DC resistencia según SAE J1128100 % de spools
Ensayos por muestreo
Pinch, sandpaper abrasión & -40 °C en frío curvaturaPasses SAE J1128 de pared delgada mecánico & en frío-curvatura criteriaBatch sample
3000 -hour térmica ageing & fluid inmersiónVerified a +85 / +105 °C y en automotive fluidsCalificación de tipo

Certificado de inspección

Emitido con cada tambor, con los resultados de los ensayos de rutina de esa longitud.

Homologaciones del producto

SAE J1128 Type TWPChrysler MS-8900Ford ESB-M1L120-AISO 6722-1 Class A / BRoHS 3 Compliant

Certificados de la empresa

ISO 9001ISO 14001ISO 45001Homologación VDEUL / cULCE · LVD / EMC

Marcado y suministro

Pedido y entrega

Marcado de la cubierta

TEBAOFLEX SAE J1128 TWP 18 AWG (0.8mm2) 60VDC THIN-WALL PVC [lot/spool]
Forma de suministro
No-returnable plástico spools, barrel packs o wooden tambores
Estándar spool pasos
500 m · 1000 m · 2000 m spools (o barrel packs)
Pedido mínimo
500 m (stock colores) · 2000 m (con franja/a medida)
Plazo de entrega
2–3 weeks ex-trabaja
Incoterms
EXW, FOB, CIF, DAP

Documentación técnica

Descargas

Revisión
2026-10-20
Actualizado
2026-10-20

Preguntas frecuentes

Las primeras preguntas de ingeniería

¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.

How much space y peso does TWP save compared con regular-pared GPT?
Por reducing nominal espesor de pared de 0.58 mm (GPT) a 0.40 mm (TWP) en 20–14 AWG tamaños, TWP lowers general alambre diámetro por roughly 0.55–0.65 mm y cuts aislamiento peso por 30–35 %, allowing menor harness haces hasta estrecho door y pillar canales.
Cuando should TXL be selected instead de TWP?
Tanto TWP y TXL share el exact mismo 0.40 mm de pared delgada dimensions en 24–14 AWG tamaños. Choose TWP para cost-effective cabin cableado hasta +85 / +105 °C; choose TXL (polietileno reticulado) para engine bays y circuitos que requieren +125 °C térmica endurance y solder/cortocircuito fusión resistencia.
What está el European métrico equivalente de SAE J1128 TWP?
El European DIN 72551 / ISO 6722-1 equivalente está FLRY-A (concéntrico 7/19-wire) o FLRY-B (en haz conductor), el cual similarly uses un de pared reducida plasticized PVC aislamiento nominal hasta +105 °C .
Se especial crimp terminals needed para de pared delgada TWP alambre?
Uso de pared delgada (TW / métrico FLR) abierto-barrel crimp terminals whose aislamiento crimp wings se sized para el menor 1.55–2.90 mm exterior diámetro de 24–14 AWG TWP alambre.

Solicitar presupuesto

Solicite una oferta técnica para TWP

La selección y los datos de aplicación se copian al formulario de consulta inferior.

01Medidas seleccionadas

Use + Añadir junto a una medida o configuración.

02Tambor y movimiento

Añada aquí las condiciones de servicio para incluirlas en su consulta.

03Mensaje para nuestros ingenieros

TWP De pared delgada Automotive Alambre

Medidas seleccionadas:


Tambor y movimiento:
- Tipo de tambor: 
- Diámetro del núcleo del tambor (mm): 
- Longitud de cable en tambor (m): 
- Velocidad de desplazamiento (m/min): 
- Aceleración máxima: 
- Ciclos por hora: 
- Longitud y cantidad: 
- Temperatura ambiente: 
- Exposición (exterior, agua, aceite, abrasión): 
- País de destino: 
- Equipo y condiciones de servicio: 
Enviar por WhatsApp

Ficha técnicaSolicitar presupuesto