Instalación fija
Clamped a lo largo de vertical, deviated y horizontal production tubing cordones hasta 30,000 ft (9,000 m) splice-libre.
Producto
1/4" Aleación 825 / 316L tubing-encapsulated downhole calibre cable (15,000–25,000 psi)
Valores típicos para este tipo de cable, basados en API 17E (ISO 13628-5) / NACE MR0175 (ISO 15156) / ASTM A269 / B423 — confirmados en la ficha técnica y oferta de su pedido.
Aplicaciones
Alto-presión, sour-servicio Tubing Encapsulated Cable (TEC) engineered a API 17E y NACE MR0175 (ISO 15156) con 18/16 AWG conductores de cobre, FEP/PEEK-PFA dieléctrico, en frío-estirado 1/4" (6.35 mm) Aleación 825 o 316L tubo y 11×11 mm PVDF/PP encapsulation.
Clamped a lo largo de vertical, deviated y horizontal production tubing cordones hasta 30,000 ft (9,000 m) splice-libre.
Hermetic 1/4" Aleación 825 o 316L tubo withstands 15,000–25,000 psi hydrostatic annulus presión, H₂S/CO₂ sour brines y completion fluids.
Square 11 × 11 mm polymeric encapsulation absorbe spider/deslizamiento impacto y evita galvanic corrosión contra el production tubing.
Designed para tramo-en-hole spooling sobre completion poleas (rayon de courbure minimal ~10–12 en.), no continuo cadenas portacables.
PUR Cadena portacables Cable de controlConstrucción
Mostrado: TEC-1C18-A825-049-PVDF con 1×18 AWG sólido conductor de cobre, FEP Aislamiento primario, polymeric amortiguador/cableado varilla relleno (para 100 % conductor soporte contra vertical slippage), 1/4" × 0.049" pared en frío-estirado Aleación 825 tubo y 11×11 mm square PVDF encapsulation.
| # | Capa | Material y referencia |
|---|---|---|
| 1 | De alta conductividad cobre downhole conductor | 1×18 AWG (0.82 mm²), 1×16 AWG (1.31 mm²) o 2×18 AWG par trenzado en desnudo, estañado o niquelado cobreProporciona bajo-attenuation DC potencia y digital calibre telemetría (tubo actúa como común retorno en 1C diseños) |
| 2 | De alta temperatura fluoropolímero dieléctrico & relleno matrix | Extruido ETFE (+150 °C), FEP (+200 °C) o doble-capa PEEK/PFA (+230/+260 °C) rodeado por bloqueado polymeric relleno rodsProporciona > 5,000 MΩ·km aislamiento resistencia a 1000 V DC y bloquea el conductor mecánicamente para que it cannot telescope hasta un 6,000 m vertical well |
| 3 | Seamless / orbital-welded & en frío-estirado 1/4" metálico tubo | 1/4" OD (6.35 mm) × 0.035" (0.89 mm) o 0.049" (1.24 mm) pared en Aleación 825 (UNS N08825), Super Duplex 2507 o AISI 316LTubo está formed alrededor del conductor y en frío-estirado (swaged) hasta a mecánicamente grip el interno cable mientras proporcionando un 15,000–25,000 psi hermetic barrera |
| 4 | 11 × 11 mm square (0.433" × 0.433") polymeric encapsulation | Injection-extruido Polipropileno (PP a +150 °C), TPV elastómero (+135 °C), PVDF (+175 °C) o FEP/PFA (+200/+230 °C), opcionalmente flanked por dos Ø 1.6 mm galvanizado acero bumper hilosProtege el 1/4" metal tubo contra aplastamiento durante tramo-en-hole y bloquea en cruz-coupling protectors |
42Ni-21Cr-3Mo-2Cu aleación certified a NACE MR0175 / ISO 15156 para H₂S, CO₂ y alto-chloride wells
316L (UNS S31603) para sweet wells; Super Duplex 2507 (UNS S32750) para alto collapse & a la tracción loads
1×18/16 AWG (tubo retorno), 2×18 AWG aislados par, o 1×18 AWG + fibras ópticas para DTS/DAS
Datos técnicos
Dimensiones
1-conductor, 2-conductor y híbrido electro-óptico TEC en AISI 316L, Aleación 825 y Super Duplex 2507 .
| Designación de pedido | Interno conductor | 1/4" Tubo aleación & pared | Dieléctrico / Encapsulation | Tubo OD mm | Total peso kg/km ≈ | Máx.. downhole temp.. | Consulta |
|---|---|---|---|---|---|---|---|
| Unipolar (1×18 AWG & 1×16 AWG) Coaxial-Retorno Downhole Calibre TEC | |||||||
| TEC-1C18-316L-035-PP | 1×18 AWG (0.82 mm²) Sólido Cu | AISI 316L · 0.035" (0.89 mm) | FEP / PP (11×11 mm) | 6.35 | 215 | +150 °C | |
| TEC-1C18-A825-035-PVDF | 1×18 AWG (0.82 mm²) Sólido Cu | Aleación 825 · 0.035" (0.89 mm) | FEP / PVDF (11×11 mm) | 6.35 | 238 | +175 °C | |
| TEC-1C18-A825-049-PVDF | 1×18 AWG (0.82 mm²) Sólido Cu | Aleación 825 · 0.049" (1.24 mm) | FEP / PVDF (11×11 mm) | 6.35 | 282 | +175 °C | |
| TEC-1C18-A825-049-PFA | 1×18 AWG (0.96 mm²) NPC/SPC | Aleación 825 · 0.049" (1.24 mm) | PEEK-PFA / FEP (11×11) | 6.35 | 295 | +230 °C | |
| TEC-1C16-A825-035-PVDF | 1×16 AWG (1.31 mm²) Sólido Cu | Aleación 825 · 0.035" (0.89 mm) | FEP / PVDF (11×11 mm) | 6.35 | 244 | +175 °C | |
| TEC-1C16-A825-049-PVDF | 1×16 AWG (1.31 mm²) Sólido Cu | Aleación 825 · 0.049" (1.24 mm) | FEP / PVDF (11×11 mm) | 6.35 | 288 | +175 °C | |
| TEC-1C16-SD2507-049-PVDF | 1×16 AWG (1.31 mm²) Sólido Cu | Super Duplex 2507 · 0.049" | FEP / PVDF (11×11 mm) | 6.35 | 280 | +175 °C | |
| Dos-Conductor (2×18 AWG Par trenzado) Aislados-Retorno Downhole TEC | |||||||
| TEC-2C18-A825-035-PVDF | 2×18 AWG (0.82 mm²) Par trenzado | Aleación 825 · 0.035" (0.89 mm) | FEP / PVDF (11×11 mm) | 6.35 | 248 | +175 °C | |
| TEC-2C18-A825-049-PVDF | 2×18 AWG (0.82 mm²) Par trenzado | Aleación 825 · 0.049" (1.24 mm) | FEP / PVDF (11×11 mm) | 6.35 | 292 | +175 °C | |
| Híbrido Electro-Óptico (1×18 AWG + 2×Monomodo Fibra) DTS/DAS + PDHG TEC | |||||||
| TEC-1C18+2SMF-A825-049 | 1×18 AWG Cu + 2×SM Fibra (FIMT) | Aleación 825 · 0.049" (1.24 mm) | PFA / PVDF (11×11 mm) | 6.35 | 290 | +200 °C | |
| 1/4" (6.35 mm) Tubo especificación | Tubo ID mm | Min. yield MPa (ksi) | De trabajo presión psi (MPa) | Tubo de rotura carga kN ≈ |
|---|---|---|---|---|
| AISI 316L × 0.035" (0.89 mm) pared | 4.57 | 205 MPa (30 ksi) | 12,500 psi (86 MPa) | 8.4 |
| Aleación 825 × 0.035" (0.89 mm) pared | 4.57 | 240 MPa (35 ksi) | 15,000 psi (103 MPa) | 10.2 |
| Aleación 825 × 0.049" (1.24 mm) pared | 3.87 | 240 MPa (35 ksi) | 20,000 psi (138 MPa) | 13.4 |
| Super Duplex 2507 × 0.049" (1.24 mm) pared | 3.87 | 550 MPa (80 ksi) | 25,000 psi (172 MPa) | 16.8 |
Calidad y homologaciones
Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.
| Ensayos e inspección | Valor de ensayo / referencia | Frecuencia |
|---|---|---|
| Ensayos de rutina | ||
| 100 % Eddy-corriente, ultrasonic weld inspección & helium leak ensayo | Cero weld/pared defects; hermeticity verified en completo continuo enrollador longitud | Cada fabricado enrollador |
| 2,500 V DC dieléctrico withstand & 1,000 V DC aislamiento resistencia ensayo | IR ≥ 5,000 MΩ·km a 20 °C; conductor & tubo continuidad verified | Cada fabricado enrollador |
Marcado y suministro
Marcado de la cubierta
Documentación técnica
Preguntas frecuentes
¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.
Solicitar presupuesto
La selección y los datos de aplicación se copian al formulario de consulta inferior.
Use + Añadir junto a una medida o configuración.