Control & señal cableAirport PBB / 400 Hz GSE300/500 V (600 V UL)-40 °C a +90 °C Cadena portacables

GP 400 SF S Control Passenger-Boarding-Bridge Cadena portacables Control-40 a +90 °C Class 6 EMC -apantallado PUR cadena portacables cable para airport boarding bridges

-40 a +90 °C Class 6 EMC -apantallado PUR cadena portacables cable para airport boarding bridges

Pantalla CEM
Diseño de baja CEM
Resistente al aceite
Ozono, UV y humedad
Designación de pedido
GP 400 SF S 12G1.5
Ø ext. ≈
14.30 mm
Espesor de pared
1.45 mm
Total peso ≈
445.1 kg/km
Min. curvatura R (fijo)
114 mm
Todas las medidas (20)
Respuesta de ingeniería en 2 horas laborablesTambores de exportación cortados a medidaCertificado EN 10204 3.1 por tambor
Tensión nominal
300/500 V
600 V UL/CSA · 3000 V ensayo
Cadena temp..
-40…+90 °C
Ártico apron cadena portacables servicio
Conductor
Cu Class 6 (SF)
Super-fino cableado (IEC 60228)
Pantalla EMC
Sn-Cu trenza (S)
≥ 85 % óptico trenza cobertura
Cubierta exterior
Aviation PUR
Resists Jet un-1 & de-icing fluid
Min radio de curvatura
7.5 × OD cadena
4 × OD fijo installation

Valores típicos para este tipo de cable, basados en EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables Especificación — confirmados en la ficha técnica y oferta de su pedido.

Aplicaciones

¿Es GP 400 SF S Control adecuado para su máquina?

GP 400 SF S Control super-flexible ('SF') apantallado ('S') cadena portacables Cable de control (-40 a +90 °C) para airport passenger boarding bridges (PBB) y 400 Hz GSE, con IEC 60228 Class 6 conductores de cobre, TPE aislamiento, Sn-Cu trenza, y aviation PUR cubierta.

Cadena portacables

Adecuado

Class 6 super-fino conductores y bajo-angle cobre estañado trenza endure millions de telescopic PBB cadena portacables ciclos hasta a -40 °C .

Alimentación apantallada variador VFD a motor

Adecuado

Trenzado Sn-Cu pantalla ('S') aísla 28 V DC aircraft interlocks, autolevellers, y PLC I/O de 400 Hz GPU harmonics.

Bandejas en plataformas offshore y buques

Adecuado

Aviation polyether- PUR cubierta resists Jet un-1 fuel, hydraulic fluid, runway formates, y glycol de-icing fluids.

Tambor monoespiral motorizado

No adecuado

Designed para linear cadenas portacables; para motorizado bajo-bridge 400 Hz enrolladores de cable, uso un dedicado 400 Hz cable para enrollador.

Uso NSHTÖU para tambor enrollado
Máquinas habitualesAirport Passenger Boarding Bridges400 Hz Tierra Potencia InterlocksPre-Conditioned Air (PCA) BoomsAircraft Docking Guidance (un-VDGS)Para climas fríos Apron Automatización

Construcción

Capa por capa

Airport PBB cadena portacables construcción: IEC 60228 Class 6 conductores de cobre, TPE/EPR Aislamiento de conductor, presión-Cubierta interior extruida, cobre estañado trenza (S), y aviation-fluid-proof PUR cubierta.

12345
Esquema sin escala — generado a partir de los datos de capas
#CapaMaterial y referencia
1Super-fino Class 6 cobre (SF)Extra-trenzado fino cobre desnudo o estañado (IEC 60228 Class 6, 0.15 mm máx. cordón diámetro)Evita cordón rotura bajo de radio estrecho telescopic PBB cadena flexión
2En frío-elastic TPE/EPR conductor paredBajo-temperatura libre de halógenos elastómero termoplástico (TPE-E/TPE-O, negro numerados + GNYE)Will no stiffen o crack durante -40 °C winter airport apron operations
3Gusset-rellenando cubierta interiorExtruido libre de halógenos elastómero cubierta interior sobre de paso corto agrupados en haces conductoresEvita conductor efecto sacacorchos dentro de largo horizontal telescopic bridge cadenas
4De baja torsión cobre estañado trenza (S)Optimizado trenza-angle alambre de cobre estañado pantalla (≥ 85 % cobertura óptica)Pantallas 28 V DC / 400 Hz aircraft seguridad interlocks y cabin autoleveller sensors
5Aviation-fluid-resistente PUR cubiertaLibre de halógenos, UV -stabilised polyether-compuesto de poliuretano TMPU (negro o naranja)Resistente a Jet un-1 fuel, glycol de-icing fluids, runway salts, y solar UV

GP 400 SF S (4G–36G × 0.75–2.5 mm²)

Apantallado PBB cadena portacables Cable de control para bridge accionamiento, autoleveller, y cabin rotation controla

GP 400 SF S Piloto (7G–18G × 1.0–1.5 mm²)

400 Hz aircraft tierra-potencia EF/E-F enclavamiento y piloto supervisión cadena portacables cable

Datos técnicos

Valores nominales y límites de servicio

Valores típicos: Valores típicos para este tipo de cable, basados en EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables Especificación. Los valores de su pedido se confirman en la ficha técnica y la oferta.

Eléctricos

Tensión nominal U0/U
300/500 V AC (600 V UL/CSA AWM)
AC dieléctrico ensayo tensión
3,000 V AC (conductor/conductor) · 1,500 V (pantalla)
Operating frecuencia
DC, 50/60 Hz & 400 Hz aircraft control
EMC trenza cobertura
≥ 85 % trenza de alambre de cobre estañado

Térmicos

Dinámico cadena portacables temp..
-40 °C a +90 °C continuo
Fijo installation temp..
-50 °C a +90 °C
En frío-curvatura impacto ensayo
-40 °C según EN 60811-504/505

Mecánicos

Cableado del conductor
IEC 60228 Class 6 super-fino cobre
Radio mínimo de curvatura (cadena)
7.5 × general cable diámetro
Radio mínimo de curvatura (fijo)
4 × general cable diámetro
Cadena recorrido & velocidad
Hasta 50 m telescopic recorrido · 3 m/s

Resistencia

Aviation fluid resistencia
Resists Jet un-1, glycol de-icers & oils
Llama & halógenos capacidad nominal
IEC 60332-1-2 / UL VW-1 · IEC 60754-1/2
UV & intemperie resistencia
ISO 4892-2 exterior airport apron UV pass

Normas de referencia

Cubierta & conductor standards
EN 50363-10-2 TMPU · IEC 60228 Class 6
Norteamericanos approval ref.
UL 758 Style 20234 / CSA AWM I/II un/B
RoHS & REACH
RoHS 3 & REACH compliant

Identificación

Color de la cubierta exterior
Jet negro (RAL 9005) o seguridad naranja
Leyenda impresa en superficie
TEBAOFLEX GP 400 SF S CONTROL [nGmm²] PBB -40 /+ 90C
Partida arancelaria (HS)
8544.49

Dimensiones

20 estándar configuraciones (GP 400 SF S Control)

Engineering dimensions, conductor cableado, masa y eléctrico ratings para GP 400 SF S Control según EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables Especificación.

Dimensiones y pesos
Designación de pedidoSección transversal / tamañoConductor construcciónPared ≈
mm
Ø ext. ≈
mm
Metal
kg/km
Peso ≈
kg/km
Min. curvatura R
fijo mm
Consulta
Estándar GP 400 SF S Control configuraciones
GP 400 SF S 4G0.754G0.75 mm²Class 6 Cu (SF) (0.75 mm²)1.257.5055.8116.660
GP 400 SF S 7G0.757G0.75 mm²Class 6 Cu (SF) (0.75 mm²)1.258.7081.7163.470
GP 400 SF S 12G0.7512G0.75 mm²Class 6 Cu (SF) (0.75 mm²)1.4511.40127.4267.891
GP 400 SF S 18G0.7518G0.75 mm²Class 6 Cu (SF) (0.75 mm²)1.4513.20177.1365.3106
GP 400 SF S 25G0.7525G0.75 mm²Class 6 Cu (SF) (0.75 mm²)1.4515.20234.7484.2122
GP 400 SF S 4G14G1 mm²Class 6 Cu (SF) (1 mm²)1.257.9066.8134.263
GP 400 SF S 7G17G1 mm²Class 6 Cu (SF) (1 mm²)1.259.20100.3191.774
GP 400 SF S 12G112G1 mm²Class 6 Cu (SF) (1 mm²)1.4512.20159.1319.898
GP 400 SF S 18G118G1 mm²Class 6 Cu (SF) (1 mm²)1.4514.10223.6438.3113
GP 400 SF S 25G125G1 mm²Class 6 Cu (SF) (1 mm²)1.4516.30298.7585.6130
GP 400 SF S 4G1.54G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.259.1090.4179.873
GP 400 SF S 7G1.57G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.2510.70139.3262.986
GP 400 SF S 12G1.512G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.4514.30224.3445.1114
GP 400 SF S 18G1.518G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.4516.60319.0616.6133
GP 400 SF S 25G1.525G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.4519.30429.5831.8154
GP 400 SF S 36G1.536G1.5 mm²Class 6 Cu (SF) (1.5 mm²)1.4522.30598.71,135.8178
GP 400 SF S 4G2.54G2.5 mm²Class 6 Cu (SF) (2.5 mm²)1.2510.30133.1247.782
GP 400 SF S 7G2.57G2.5 mm²Class 6 Cu (SF) (2.5 mm²)1.2512.10211.6369.797
GP 400 SF S 12G2.512G2.5 mm²Class 6 Cu (SF) (2.5 mm²)1.4516.20346.3629.7130
GP 400 SF S 4G44G4 mm²Class 6 Cu (SF) (4 mm²)1.2512.60199.0370.5101
  • Valores típicos para este tipo de cable; las dimensiones y pesos de su pedido se confirman en la oferta.
  • Exterior diameters y weights se nominal engineering values para GP 400 SF S Control subject a estándar manufacturing tolerances según EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables Especificación.

Calidad y homologaciones

Ensayos e inspección

Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.

  1. ConductorCuerda clase 5
  2. Ensayo de chispa100 % en línea
  3. CableadoConductores, tierra, rellenos
  4. Extrusión de cubiertaInterior, trenza / pantalla, exterior
  5. Ensayos eléctricosTensión CA, resistencia
  6. DimensionesDE, espesor de pared
  7. Documentos de inspección y expediciónTambor y expedición
Ensayos e inspecciónValor de ensayo / referenciaFrecuencia
Ensayos de rutina
Dieléctrico spark / De alta tensión withstand ensayo100 % en-line spark y AC/DC dieléctrico withstand según EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables EspecificaciónCada longitud fabricada
Conductor DC resistencia & continuidad supervisiónDentro de máximo 20 °C resistencia limit especificado para GP 400 SF S ControlCada spool o tambor longitud
Ensayos por muestreo
Aislamiento resistencia & dimensional verificationEspesor de pared, concentricity y aislamiento resistencia según EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables EspecificaciónPor lote de producción
Environmental, mecánico & EMC qualificationQualified a EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables Especificación térmica, mecánico y environmental performance criteriaCalificación de tipo

Certificado de inspección

Emitido con cada tambor, con los resultados de los ensayos de rutina de esa longitud.

Homologaciones del producto

EN 50525 / UL 758 / ISO 19659 Airport PBB Cadena portacables EspecificaciónCE (2014/35/EU) & RoHS 3 (2015/863/EU) CompliantREACH SVHC Conformidad Verified

Certificados de la empresa

ISO 9001ISO 14001ISO 45001Homologación VDEUL / cULCE · LVD / EMC

Marcado y suministro

Pedido y entrega

Marcado de la cubierta

TEBAOFLEX GP 400 SF S CONTROL 12G1.5 PBB DRAG-CHAIN -40 / +90°C
Forma de suministro
Export wooden tambores, tactical enrolladores o coils
Estándar pasos
100 m · 500 m · 1000 m (o a medida corte pasos)
Pedido mínimo
100 m (stock tamaños) · 300–500 m (a medida construcción)
Plazo de entrega
2–4 weeks ex-trabaja
Incoterms
EXW, FOB, CIF, DAP

Documentación técnica

Descargas

Revisión
2026-10-20
Actualizado
2026-10-20

Preguntas frecuentes

Las primeras preguntas de ingeniería

¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.

Why airport passenger boarding bridges (PBB) require un dedicado '-40 °C' cadena portacables Cable de control?
Passenger boarding bridges se alojan expuesto en exterior airport aprons year-redondo. En frío climates, estándar PVC o nitrile cadena portacables cables stiffen below -15 °C y fracture cuando el telescopic bridge tunnels extend a meet un arriving aircraft. GP 400 SF S Control uses TPE conductores y polyether- PUR a stay supple a -40 °C .
Why está EMC trenza de cobre apantallamiento ('S') critical dentro de un passenger boarding bridge cadena portacables?
El PBB cadena portacables typically soporta principal 400 V bridge accionamiento motor alimentadores y 400 Hz aircraft tierra cables de potencia junto con 24 V autoleveller sensors, wheel encoders, y 28 V DC aircraft enclavamiento circuitos. un ≥ 85 % cobre estañado trenza evita 400 Hz harmonic coupling.
Does el cubierta exterior resisten aircraft de-icing fluids y jet fuel spills?
Yes. El TMPU polyether-poliuretano cubierta exterior resists Type I–IV propileno/etileno glycol aircraft de-icing fluids, potassium acetate/formate runway de-icers, Jet un-1 kerosene, y hydraulic oils.
What does 'SF S' mean en GP 400 SF S Control?
'GP 400' identifies el 400 Hz Tierra Potencia / Boarding Bridge serie, 'SF' stands para Super-Fino (IEC 60228 Class 6) cadena portacables cableado, y 'S' stands para Apantallado (trenzado cobre estañado EMC pantalla).

Solicitar presupuesto

Solicite una oferta técnica para GP 400 SF S Control

La selección y los datos de aplicación se copian al formulario de consulta inferior.

01Medidas seleccionadas

Use + Añadir junto a una medida o configuración.

02Tambor y movimiento

Añada aquí las condiciones de servicio para incluirlas en su consulta.

03Mensaje para nuestros ingenieros

GP 400 SF S Control Passenger-Boarding-Bridge Cadena portacables Control

Medidas seleccionadas:


Tambor y movimiento:
- Tipo de tambor: 
- Diámetro del núcleo del tambor (mm): 
- Longitud de cable en tambor (m): 
- Velocidad de desplazamiento (m/min): 
- Aceleración máxima: 
- Ciclos por hora: 
- Longitud y cantidad: 
- Temperatura ambiente: 
- Exposición (exterior, agua, aceite, abrasión): 
- País de destino: 
- Equipo y condiciones de servicio: 
Enviar por WhatsApp

Ficha técnicaSolicitar presupuesto