IEC 60584-3 Type KCB (VX) compensating cableIEC 60584-3 Type KCB (VX)Cu (+) / CuNi (−) No-Magnetic0…+100 °C Junction Gama

Modelo KCB Thermocouple Compensating CableCu / CuNi (VX) compensating cable para Type K thermocouples (0…+100 °C junctions)

Cu / CuNi (VX) compensating cable para Type K thermocouples (0…+100 °C junctions)

Diseño de baja CEM
Pantalla CEM
Retardante de llama
Resistente al aceite
Designación de pedido
KCB-PVC-PiMF 4×2×1.5
Ø ext. ≈
14.3 mm
Total peso ≈
286 kg/km
Min. curvatura R (fijo)
107 mm
Configuración
4×2×1.5 mm² (7/0.53)
Todas las medidas (15)
Respuesta de ingeniería en 2 horas laborablesTambores de exportación cortados a medidaCertificado EN 10204 3.1 por tambor
Compensates para
Type K (NiCr-Ni)
IEC 60584-3 KCB (convencional VX)
Aleación par
Cu (+) / CuNi
Puro Cobre (+) / CuNi 55/45 (−)
Junction gama
0 °C a +100 °C
en frío-junction transition gama
EMF tolerance
Class 2: ±2.5 °C
±100 µV (measured a 900 °C)
Bucle resistencia
≈ 0.51 Ω/m/par
a 1.0 mm² (0.018 + 0.49 Ω/m)
IEC código de colores
+ Verde / − Wh
Verde cubierta exterior (o Ex-i Azul)

Valores típicos para este tipo de cable, basados en IEC 60584-3 / BS 4937-30 / BS EN 50288-7 — confirmados en la ficha técnica y oferta de su pedido.

Aplicaciones

¿Es KCB adecuado para su máquina?

Economical, no-magnetic Type KCB (anteriormente British VX) thermocouple compensating cable built a IEC 60584-3 con Cobre (+ Cu) y Cobre-Níquel (− CuNi) conductores calibrated a match el Type K (NiCr-NiAl) EMF slope sobre 0 °C a +100 °C .

Instalación fija

Adecuado

Supplied en PVC, XLPE/LSZH y SWA armado multi-par trunks (hasta 24 pares) para bandejas portacables, racks y risers.

Pórtico de tuneladora TBM y avance

Adecuado

SWA armado ejecución (KCB-XLPE-SWA) protege subterráneo refinery, potencia-station y chemical plant trunk tendidos.

Bandejas en plataformas offshore y buques

Adecuado

No-ferrous Cu/CuNi conductores will never rust en humid coastal o costa afuera atmospheres.

Máquinas habitualesAceite Refineries, LNG & Petrochemical ComplexesCombinado-Ciclo & Biomass Potencia StationsChemical & Pharmaceutical Proceso PlantsAgua, Waste-a-Energía & Incineration PlantsIndustrial Boiler & HVAC Marshalling Trunks

Construcción

Capa por capa

Mostrado: KCB-PVC -PiMF 8×2×1.0 mm² (IEC 60584-3) con de 7 hilos cableado Cu (+) y CuNi (−) compensating conductores, Verde (+) / Blanco (−) numerados aislamiento, individual & colectiva Al/ PET pantallas y Verde RAL 6018 cubierta exterior.

12345
Esquema sin escala — generado a partir de los datos de capas
#CapaMaterial y referencia
1Matched Type KCB (VX) compensating conductoresPositive (+): De alta conductividad Cobre (Cu) · Negative (−): Cobre-Níquel (CuNi ~55/45), de 7 hilos cableado, tanto no-magneticMatches Type K ~40.6 µV/°C slope sobre 0…+100 °C mientras cutting bucle resistencia en mitad vs KX
2Codificados por colores Aislamiento de conductorRetardante de la llama PVC o XLPE (IEC 60584-3: + Verde / − Blanco, numerados pares para multi-par)Bajo dieléctrico loss y clear par identificación
3Individual & colectiva Al/ PET pantallasAluminio/ PET laminated cinta + 0.5 mm² cobre estañado drenaje alambre (OS o PiMF+OS)100 % electrostática apantallamiento contra plant VFD noise
4Opcional SWA armaduraSin armadura (Type 1) o Galvanizado Acero Alambre Armadura (SWA, Type 2) sobre asientoAplastamiento y roedores protección para subterráneo y pipe-rack trunks
5Cubierta exterior (Verde RAL 6018 o Azul RAL 5015 Ex-i)Retardante de la llama PVC o Baja emisión de humos Libre de halógenos (LSZH)IEC 60332-1-2 / IEC 60332-3-24 Cat. C retardante de la llama

KCB — IEC 60584-3 (Verde/Blanco)

Positive (+) Verde, Negative (−) Blanco, Cubierta exterior Verde (RAL 6018)

KCB Ex-i (Azul Cubierta exterior)

Verde (+) / Blanco (−) conductores con RAL 5015 Azul cubierta exterior para ATEX Ex-i lazos

KCB-XLPE-SWA (Armado Trunk)

XLPE aislado, SWA armado, PVC o LSZH con cubierta para subterráneo multi-par tendidos

Datos técnicos

Valores nominales y límites de servicio

Valores típicos: Valores típicos para este tipo de cable, basados en IEC 60584-3 / BS 4937-30 / BS EN 50288-7. Los valores de su pedido se confirman en la ficha técnica y la oferta.

Eléctricos

Compensado thermocouple Tipo
Type K (NiCr-NiAl) según IEC 60584-1 (convencional British código VX)
Positive conductor (+)
De alta conductividad Cobre (Cu, no-magnetic, ~1.72 µΩ·cm)
Negative conductor (−)
Calibrated Cobre-Níquel (CuNi ~55/45, no-magnetic, ~49 µΩ·cm)
Tolerance Class 2 (IEC 60584-3)
±2.5 °C (±100 µV) sobre 0 °C a +100 °C junction gama
Bucle resistencia @ 20 °C
≈ 1.02 Ω/m (0.5 mm²) · 0.51 Ω/m (1.0 mm²) · 0.34 Ω/m (1.5 mm²)

Térmicos

Permissible junction temperatura gama
0 °C a +100 °C (uso KCA o KX if cabezal exceeds +100 °C)
Cable operating temperatura
−25…+100 °C (PVC) · −40…+90 °C (XLPE/LSZH)

Mecánicos

Cableado del conductor
0.5 mm² (7/0.30) · 1.0 mm² (7/0.43) · 1.5 mm² (7/0.53)
Radio mínimo de curvatura
7.5 × OD (sin armadura) · 10 × OD (SWA armado)

Resistencia

Retardancia de la llama
IEC 60332-1-2 & IEC 60332-3-24 Cat. C
Corrosión resistencia
100 % no-ferrous Cu/CuNi conductores (sin rusting en marino/costa afuera air)

Normas de referencia

Thermocouple cable estándar
IEC 60584-3 & BS 4937-30 (convencional VX)
Cable construcción estándar
BS EN 50288-7 & BS 5308 Parte 1 / Parte 2

Identificación

IEC 60584-3 código de colores
(+) Verde · (−) Blanco · Cubierta exterior: Verde (o Azul Ex-i)
Convencional BS 1843 / BS 4937 VX
(+) Blanco · (−) Azul · Cubierta exterior: Rojo (disponible bajo pedido)
Partida arancelaria (HS)
8544.49

Dimensiones

15 estándar KCB (VX) Type K compensating cable tamaños

1 a 24 pares en 0.5, 1.0 y 1.5 mm² con PVC/PVC o XLPE/LSZH/SWA armado construcción.

Dimensions, construcción & weights
Designación de pedidoConfiguraciónAislamiento / CubiertaJunction gamaØ ext. ≈
mm
Peso ≈
kg/km
Min. curvatura R
fijo mm
Consulta
KCB PVC / PVC Apantallado Proceso & Marshalling Trunks (0…+100 °C)
KCB-PVC-OS 1×2×0.51×2×0.5 mm² (7/0.30)PVC / PVC (OS)0…+100 °C5.64442
KCB-PVC-PiMF 2×2×0.52×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C8.68464
KCB-PVC-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C10.814281
KCB-PVC-PiMF 8×2×0.58×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C14.1246106
KCB-PVC-PiMF 12×2×0.512×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C16.9348127
KCB-PVC-PiMF 24×2×0.524×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C23.2642174
KCB-PVC-OS 1×2×1.01×2×1.0 mm² (7/0.43)PVC / PVC (OS)0…+100 °C6.76850
KCB-PVC-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C12.821296
KCB-PVC-PiMF 8×2×1.08×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C16.9378127
KCB-PVC-OS 1×2×1.51×2×1.5 mm² (7/0.53)PVC / PVC (OS)0…+100 °C7.59256
KCB-PVC-PiMF 4×2×1.54×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C14.3286107
KCB-PVC-PiMF 8×2×1.58×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C19.2515144
KCB XLPE / LSZH / SWA Armado Directo-Burial Trunks (0…+90 °C)
KCB-XLPE-SWA 1×2×1.51×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C12.1298121
KCB-XLPE-SWA 4×2×1.54×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C19.8745198
KCB-XLPE-SWA 8×2×1.58×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C25.41,210254
  • Valores típicos para este tipo de cable; las dimensiones y pesos de su pedido se confirman en la oferta.
  • KCB está calibrated strictly para transition junctions entre 0 °C y +100 °C .

Calidad y homologaciones

Ensayos e inspección

Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.

  1. ConductorCuerda clase 5
  2. Ensayo de chispa100 % en línea
  3. CableadoConductores, tierra, rellenos
  4. Extrusión de cubiertaInterior, trenza / pantalla, exterior
  5. Ensayos eléctricosTensión CA, resistencia
  6. DimensionesDE, espesor de pared
  7. Documentos de inspección y expediciónTambor y expedición
Ensayos e inspecciónValor de ensayo / referenciaFrecuencia
Ensayos de rutina
Thermoelectric EMF calibration ensayo (IEC 60584-3 Class 2)EMF deviation dentro de ±2.5 °C (±100 µV) a +100 °C reference temperaturaCada aleación batch
1500 V / 2000 V AC dieléctrico & continuidad ensayo1 min AC withstand ensayo sin breakdownCada fabricado tambor

Certificado de inspección

Emitido con cada tambor, con los resultados de los ensayos de rutina de esa longitud.

Homologaciones del producto

IEC 60584-3 Class 2 (KCB) CertifiedBS EN 50288-7 & BS 5308 CompliantCE, RoHS 2 (2011/65/EU) & REACH

Certificados de la empresa

ISO 9001ISO 14001ISO 45001Homologación VDEUL / cULCE · LVD / EMC

Marcado y suministro

Pedido y entrega

Marcado de la cubierta

TEBAOFLEX KCB (VX) TYPE K COMPENSATING <size> IEC 60584-3 CLASS 2 CE
Forma de suministro
No-returnable fumigated wooden tambores
Estándar pasos
500 m · 1000 m estándar tambores (corte pasos bajo pedido)
Pedido mínimo
500 m (stock tamaños) · 1000 m (a medida)
Plazo de entrega
2–4 weeks ex-trabaja
Incoterms
EXW, FCA, FOB, CIF, DAP

Documentación técnica

Descargas

Revisión
2026-10-20
Actualizado
2026-10-20

Preguntas frecuentes

Las primeras preguntas de ingeniería

¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.

Está KCB el mismo como el convencional British código VX?
Yes. Bajo el former British Estándar BS 1843 / BS 4937, Cobre / Cobre-Níquel compensating cable para Type K thermocouples was designated 'VX'. Bajo IEC 60584-3, it está designated 'KCB' (+ Verde / − Blanco). Tanto uso el mismo Cu (+) / CuNi (−) aleación par calibrated sobre 0 °C a +100 °C .
What happens if un junction caja wired con KCB exceeds +100 °C?
Y superiores +100 °C, el Seebeck curve de Cu/CuNi diverges rapidly de that de NiCr/NiAl (Type K), introducing errors well beyond ±2.5 °C . If el thermocouple connection cabezal o marshalling caja CAN exceed +100 °C, especifique KCA (nominal a +200 °C) o verdadera KX extension cable.
Why está KCB para que popular para costa afuera platforms y coastal refineries?
Unlike KCA (el cual uses un Iron positive leg) o KX (el cual uses costly Níquel-Chromium / Níquel-Aluminio), KCB uses no-ferrous Cobre y Cobre-Níquel conductores that se supple a terminate, resistente a la corrosión en salino air, y economical en de 12 pares o de 24 pares armado trunks.
How should el pantalla y drenaje alambre de KCB be earthed en instrumentación y Ex-i lazos?
A evitar circulating 50/60 Hz tierra-bucle corrientes de coupling en millivolt o 4–20 mA señales, el Al/ PET pantalla y cobre estañado drenaje alambre de KCB should be adherido al limpio instrumentación tierra bar a un extremo solo (typically en el control/marshalling cabinet) y aislado contra chassis contacto al campo transmitter o junction caja, en accordance con IEC 60079-14 y EN 50288-7 .

Solicitar presupuesto

Solicite una oferta técnica para KCB

La selección y los datos de aplicación se copian al formulario de consulta inferior.

01Medidas seleccionadas

Use + Añadir junto a una medida o configuración.

02Tambor y movimiento

Añada aquí las condiciones de servicio para incluirlas en su consulta.

03Mensaje para nuestros ingenieros

Modelo KCB Thermocouple Compensating Cable

Medidas seleccionadas:


Tambor y movimiento:
- Tipo de tambor: 
- Diámetro del núcleo del tambor (mm): 
- Longitud de cable en tambor (m): 
- Velocidad de desplazamiento (m/min): 
- Aceleración máxima: 
- Ciclos por hora: 
- Longitud y cantidad: 
- Temperatura ambiente: 
- Exposición (exterior, agua, aceite, abrasión): 
- País de destino: 
- Equipo y condiciones de servicio: 
Enviar por WhatsApp

Ficha técnicaSolicitar presupuesto