IEC 60584-3 Type KCB (VX) compensating câbleIEC 60584-3 Type KCB (VX)Cu (+) / CuNi (−) Non-Magnetic0…+100 °C Junction Gamme

KCB Thermocouple Compensating CâbleCu / CuNi (VX) compensating câble pour Type K thermocouples (0…+100 °C junctions)

Cu / CuNi (VX) compensating câble pour Type K thermocouples (0…+100 °C junctions)

Conception faible CEM
Écran CEM
Ignifuge
Résistant à l’huile
Désignation de commande
KCB-PVC-PiMF 4×2×1.5
Ø ext. ≈
14.3 mm
Total masse ≈
286 kg/km
Min. courbure R (fixe)
107 mm
Configuration
4×2×1.5 mm² (7/0.53)
Toutes les dimensions (15)
Réponse technique sous 2 heures ouvréesTourets d’exportation coupés à la longueurCertificat EN 10204 3.1 par touret
Compensates pour
Type K (NiCr-Ni)
IEC 60584-3 KCB (existant VX)
Alliage paire
Cu (+) / CuNi
Pur Cuivre (+) / CuNi 55/45 (−)
Junction gamme
0 °C à +100 °C
à froid-junction transition gamme
EMF tolerance
Class 2: ±2.5 °C
±100 µV (measured à 900 °C)
Boucle résistance
≈ 0.51 Ω/m/paire
à 1.0 mm² (0.018 + 0.49 Ω/m)
IEC code couleur
+ Vert / − Wh
Vert gaine extérieure (ou Ex-i Bleu)

Valeurs types pour ce type de câble, basés sur IEC 60584-3 / BS 4937-30 / BS EN 50288-7 — confirmées dans la fiche technique et le devis de votre commande.

Applications

KCB convient-il à votre machine ?

Economical, non-magnetic Type KCB (anciennement British VX) thermocouple compensating câble built à IEC 60584-3 avec Cuivre (+ Cu) et Cuivre-Nickel (− CuNi) conducteurs calibrated à match le Type K (NiCr-NiAl) EMF slope sur 0 °C à +100 °C .

Installation fixe

Adapté

Supplied dans PVC, XLPE/LSZH et SWA armé multi-paire trunks (jusqu'à 24 paires) pour chemins de câbles, racks et risers.

Portique de tunnelier TBM et avancement

Adapté

SWA armé exécution (KCB-XLPE-SWA) protège souterrain refinery, puissance-station et chemical plant trunk liaisons.

Chemins de câbles offshore et navires

Adapté

Non-ferrous Cu/CuNi conducteurs will never rust dans humid coastal ou en mer atmospheres.

Machines typesHuile Refineries, LNG & Petrochemical ComplexesCombiné-Cycle & Biomass Puissance StationsChemical & Pharmaceutical Procédé PlantsEau, Waste-à-Énergie & Incineration PlantsIndustriel Boiler & HVAC Marshalling Trunks

Construction

Couche par couche

Illustré: KCB-PVC -PiMF 8×2×1.0 mm² (IEC 60584-3) avec à 7 fils toronné Cu (+) et CuNi (−) compensating conducteurs, Vert (+) / Blanc (−) numérotés isolation, individuel & collectif Al/ PET écrans et Vert RAL 6018 gaine extérieure.

12345
Schéma sans échelle — généré à partir des données des couches
#CoucheMatériau et référence
1Matched Type KCB (VX) compensating conducteursPositive (+): Haute conductivité Cuivre (Cu) · Negative (−): Cuivre-Nickel (CuNi ~55/45), à 7 fils toronné, à la fois non-magneticMatches Type K ~40.6 µV/°C slope sur 0…+100 °C tout en cutting boucle résistance dans moitié vs KX
2Repérés par couleurs Isolation de conducteurIgnifuge PVC ou XLPE (IEC 60584-3: + Vert / − Blanc, numérotés paires pour multi-paire)Faible diélectrique loss et clear paire identification
3Individuel & collectif Al/ PET écransAluminium/ PET laminated ruban + 0.5 mm² cuivre étamé drain fil (OS ou PiMF+OS)100 % électrostatique blindage contre plant VFD noise
4En option SWA armureNon armé (Type 1) ou Galvanisé Acier Fil Armure (SWA, Type 2) sur bourrageÉcrasement et rongeurs protection pour souterrain et pipe-rack trunks
5Gaine extérieure (Vert RAL 6018 ou Bleu RAL 5015 Ex-i)Ignifuge PVC ou Faible émission de fumée Sans halogène (LSZH)IEC 60332-1-2 / IEC 60332-3-24 Cat. C ignifuge

KCB — IEC 60584-3 (Vert/Blanc)

Positive (+) Vert, Negative (−) Blanc, Gaine extérieure Vert (RAL 6018)

KCB Ex-i (Bleu Gaine extérieure)

Vert (+) / Blanc (−) conducteurs avec RAL 5015 Bleu gaine extérieure pour ATEX Ex-i boucles

KCB-XLPE-SWA (Armé Trunk)

XLPE isolé, SWA armé, PVC ou LSZH gainé pour souterrain multi-paire liaisons

Données techniques

Valeurs nominales et limites de service

Valeurs types: Valeurs types pour ce type de câble, basés sur IEC 60584-3 / BS 4937-30 / BS EN 50288-7. Les valeurs de votre commande sont confirmées dans la fiche technique et le devis.

Électriques

Compensé thermocouple Type
Type K (NiCr-NiAl) selon IEC 60584-1 (existant British code VX)
Positive conducteur (+)
Haute conductivité Cuivre (Cu, non-magnetic, ~1.72 µΩ·cm)
Negative conducteur (−)
Calibrated Cuivre-Nickel (CuNi ~55/45, non-magnetic, ~49 µΩ·cm)
Tolerance Class 2 (IEC 60584-3)
±2.5 °C (±100 µV) sur 0 °C à +100 °C junction gamme
Boucle résistance @ 20 °C
≈ 1.02 Ω/m (0.5 mm²) · 0.51 Ω/m (1.0 mm²) · 0.34 Ω/m (1.5 mm²)

Thermiques

Permissible junction température gamme
0 °C à +100 °C (utilisation KCA ou KX if tête exceeds +100 °C)
Câble operating température
−25…+100 °C (PVC) · −40…+90 °C (XLPE/LSZH)

Mécaniques

Toronnage du conducteur
0.5 mm² (7/0.30) · 1.0 mm² (7/0.43) · 1.5 mm² (7/0.53)
Rayon minimal de courbure
7.5 × OD (non armé) · 10 × OD (SWA armé)

Résistance

Non-propagation de la flamme
IEC 60332-1-2 & IEC 60332-3-24 Cat. C
Corrosion résistance
100 % non-ferrous Cu/CuNi conducteurs (sans rusting dans marin/en mer air)

Normes de référence

Thermocouple câble standard
IEC 60584-3 & BS 4937-30 (existant VX)
Câble construction standard
BS EN 50288-7 & BS 5308 Partie 1 / Partie 2

Identification

IEC 60584-3 code couleur
(+) Vert · (−) Blanc · Gaine extérieure: Vert (ou Bleu Ex-i)
Existant BS 1843 / BS 4937 VX
(+) Blanc · (−) Bleu · Gaine extérieure: Rouge (disponible sur demande)
Code tarifaire douanier (HS)
8544.49

Dimensions

15 standard KCB (VX) Type K compensating câble sections

1 à 24 paires dans 0.5, 1.0 et 1.5 mm² avec PVC/PVC ou XLPE/LSZH/SWA armé construction.

Dimensions, construction & weights
Désignation de commandeConfigurationIsolation / GaineJunction gammeØ ext. ≈
mm
Masse ≈
kg/km
Min. courbure R
fixe mm
Demande
KCB PVC / PVC Blindé Procédé & Marshalling Trunks (0…+100 °C)
KCB-PVC-OS 1×2×0.51×2×0.5 mm² (7/0.30)PVC / PVC (OS)0…+100 °C5.64442
KCB-PVC-PiMF 2×2×0.52×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C8.68464
KCB-PVC-PiMF 4×2×0.54×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C10.814281
KCB-PVC-PiMF 8×2×0.58×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C14.1246106
KCB-PVC-PiMF 12×2×0.512×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C16.9348127
KCB-PVC-PiMF 24×2×0.524×2×0.5 mm² (7/0.30)PVC / PVC (PiMF+OS)0…+100 °C23.2642174
KCB-PVC-OS 1×2×1.01×2×1.0 mm² (7/0.43)PVC / PVC (OS)0…+100 °C6.76850
KCB-PVC-PiMF 4×2×1.04×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C12.821296
KCB-PVC-PiMF 8×2×1.08×2×1.0 mm² (7/0.43)PVC / PVC (PiMF+OS)0…+100 °C16.9378127
KCB-PVC-OS 1×2×1.51×2×1.5 mm² (7/0.53)PVC / PVC (OS)0…+100 °C7.59256
KCB-PVC-PiMF 4×2×1.54×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C14.3286107
KCB-PVC-PiMF 8×2×1.58×2×1.5 mm² (7/0.53)PVC / PVC (PiMF+OS)0…+100 °C19.2515144
KCB XLPE / LSZH / SWA Armé Direct-Burial Trunks (0…+90 °C)
KCB-XLPE-SWA 1×2×1.51×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C12.1298121
KCB-XLPE-SWA 4×2×1.54×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C19.8745198
KCB-XLPE-SWA 8×2×1.58×2×1.5 mm² (7/0.53)XLPE / SWA / LSZH0…+90 °C25.41,210254
  • Valeurs types pour ce type de câble ; les dimensions et masses de votre commande sont confirmées dans le devis.
  • KCB est calibrated strictly pour transition junctions entre 0 °C et +100 °C .

Qualité et homologations

Essais et contrôle

Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.

  1. ConducteurToronnage classe 5
  2. Essai à l’étincelle100 % en ligne
  3. AssemblageConducteurs, terre, bourrages
  4. GainageIntérieure, tresse / écran, extérieure
  5. Essais électriquesTension CA, résistance
  6. DimensionsDE, épaisseur de paroi
  7. Documents de contrôle et expéditionTouret et expédition
Essais et contrôleValeur d’essai / référenceFréquence
Essais individuels
Thermoelectric EMF calibration essai (IEC 60584-3 Class 2)EMF deviation au sein de ±2.5 °C (±100 µV) à +100 °C reference températureChaque alliage batch
1500 V / 2000 V AC diélectrique & continuité essai1 min AC withstand essai sans breakdownChaque fabriqué tambour

Certificat de contrôle

Délivré avec chaque touret, indiquant les résultats des essais individuels pour cette longueur.

Homologations du produit

IEC 60584-3 Class 2 (KCB) CertifiedBS EN 50288-7 & BS 5308 CompliantCE, RoHS 2 (2011/65/EU) & REACH

Certificats de l’entreprise

ISO 9001ISO 14001ISO 45001Homologation VDEUL / cULCE · LVD / EMC

Marquage et livraison

Commande et livraison

Marquage de la gaine

TEBAOFLEX KCB (VX) TYPE K COMPENSATING <size> IEC 60584-3 CLASS 2 CE
Conditionnement de livraison
Non-returnable fumigated wooden tambours
Standard pas
500 m · 1000 m standard tambours (coupure pas sur demande)
Commande minimale
500 m (stock sections) · 1000 m (sur mesure)
Délai de livraison
2–4 weeks ex-travaille
Incoterms
EXW, FCA, FOB, CIF, DAP

Documents techniques

Téléchargements

Révision
2026-10-20
Mise à jour
2026-10-20

FAQ

Les premières questions des ingénieurs

Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.

Est KCB le même comme le existant British code VX?
Yes. Sous le former British Standard BS 1843 / BS 4937, Cuivre / Cuivre-Nickel compensating câble pour Type K thermocouples was designated 'VX'. Sous IEC 60584-3, it est designated 'KCB' (+ Vert / − Blanc). À la fois utilisation le même Cu (+) / CuNi (−) alliage paire calibrated sur 0 °C à +100 °C .
What happens if un junction coffret wired avec KCB exceeds +100 °C?
Et plus +100 °C, le Seebeck curve de Cu/CuNi diverges rapidly de that de NiCr/NiAl (Type K), introducing errors well beyond ±2.5 °C . If le thermocouple connection tête ou marshalling coffret CAN exceed +100 °C, spécifier KCA (assigné à +200 °C) ou véritable KX extension câble.
Why est KCB afin que popular pour en mer platforms et coastal refineries?
Unlike KCA (lequel uses un Iron positive leg) ou KX (lequel uses costly Nickel-Chromium / Nickel-Aluminium), KCB uses non-ferrous Cuivre et Cuivre-Nickel conducteurs that sont supple à terminate, résistant à la corrosion dans salin air, et economical dans à 12 paires ou à 24 paires armé trunks.
How should le écran et drain fil de KCB be earthed dans instrumentation et Ex-i boucles?
À empêcher circulating 50/60 Hz terre-boucle courants de coupling en millivolt ou 4–20 mA signaux, le Al/ PET écran et cuivre étamé drain fil de KCB should be lié à le propre instrumentation terre bar à un extrémité uniquement (typically dans le commande/marshalling cabinet) et isolé contre chassis contact à le champ transmitter ou junction coffret, dans accordance avec IEC 60079-14 et EN 50288-7 .

Demander un devis

Obtenez un devis technique pour KCB

Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.

01Dimensions sélectionnées

Utilisez + Ajouter à côté d’une dimension ou configuration.

02Enrouleur et mouvement

Ajoutez ici vos conditions de service pour les inclure dans votre demande.

03Message pour nos ingénieurs

KCB Thermocouple Compensating Câble

Dimensions sélectionnées:


Enrouleur et mouvement:
- Type d’enrouleur: 
- Diamètre du noyau du tambour (mm): 
- Longueur de câble sur tambour (m): 
- Vitesse de déplacement (m/min): 
- Accélération maximale: 
- Cycles par heure: 
- Longueur et quantité: 
- Température ambiante: 
- Exposition (extérieur, eau, huile, abrasion): 
- Pays de destination: 
- Équipement et conditions de service: 
Envoyer par WhatsApp

Fiche techniqueDemander un devis