CSA TECK90 / ACWU90 & UL 2225 MC-HL Armado Industrial Cables de potencia600 V / 2.4 kV / 5–15 kV UL 2225Impervious Welded Corrugated Al (CWCMC)NEC Class I Div. 1 / Zona 1 + VFD

MC-HL Potencia Metal-Revestido Potencia Cable600 V a 15 kV UL 2225 Class I Div. 1 continuously welded & corrugated aluminio MC-HL potencia

600 V a 15 kV UL 2225 Class I Div.

360° Welded Al Cubierta + 3 Tierras (VFD)
Impervious Gas/Vapor Barrera (UL 2225)
UL 1685 / IEEE 1202 / FT4 Bandeja Llama
UL 2225 MC-HL / ABS / Coast Guard
Designación de pedido
MC-HL 3C 8 AWG
Ø ext. nom.
19.60 mm
Masa de cobre
248.0 kg/km
Total masa ≈
510.0 kg/km
Radio mín. curvatura
137.2 mm
Todas las medidas (13)
Respuesta de ingeniería en 2 horas laborablesTambores de exportación cortados a medidaCertificado EN 10204 3.1 por tambor
Tensiones nominales
600 V a 15 kV
600 V, 1/2 kV VFD, 5 kV & 15 kV
Peligroso capacidad nominal
Class I Div. 1 &
NEC Art. 501 / 505 Zona 1 & 2
Metálico cubierta
Continuously wel
Impervious corrugated CWCMC tubo
Puesta a tierra / VFD
3 simétrico gr
Bajo en modo común VFD impedancia
Aislamiento de conductores
XHHW-2 XLPE o E
90 °C húmedo/seco (+130 °C overload)
Operating temp.
-40 a +90 °C
Costa afuera, refinery & LNG nominal

Valores típicos para este tipo de cable, basados en UL 2225 / UL 1569 / NEC Art. 330 & 501 — confirmados en la ficha técnica y oferta de su pedido.

Aplicaciones

¿Es MC-HL Power adecuado para su máquina?

MC-HL Potencia (Metal-Revestido Peligroso Location) está un gas- y vapour-estrecho armado potencia y VFD cable listed a UL 2225 y UL 1569 para NEC Class I División 1 (y Zona 1) explosive atmospheres. Unlike interlocked-pelado Type MC o TECK90, MC-HL features un imper

Instalación fija

Adecuado

Reemplaza rigid explosion-proof acero galvanizado conducto y poured conducto seals en Class I Div. 1 zones.

Conexión de motores, tracción y convertidores

Adecuado

360° sólido welded aluminio tubo + 3 Tierras simétricas contain 100 % de VFD de alta frecuencia radiated EMI .

Cableado de celdas y armarios de control

Adecuado

Terminates en UL 2225 listed MC-HL compuesto-barrera elastómero cable prensaestopas.

Tambor monoespiral motorizado

No adecuado

Fijo installation metal-revestido potencia cable; no para enrollado tambores.

SEOOW 600 V portátil cordón
Máquinas habitualesCosta afuera aceite & gas platforms / FPSOsLNG terminals & gas processingRefinery Class I Div. 1 peligroso zonasIndustrial VFD motor alimentadoresChemical & pharmaceutical plants

Construcción

Capa por capa

3 × Class B cableado cobre Conductores de fase + XHHW-2 polietileno reticulado (o EPR) aislamiento + 3 × desnudo cableado cobre tierras en el intersticios exteriores + poliéster cinta de sujeción + continuously welded y corrugated impervious aluminio cubierta (CWCMC) + luz solar- y resistente al aceite PVC o CPE cubierta exterior.

12345
Esquema sin escala — generado a partir de los datos de capas
#CapaMaterial y referencia
13 × cableado cobre Conductores de faseCompressed concéntrico cableado recocido cobre desnudo o estañado (14 AWG a 750 MCM) según UL 1569 / UL 44UL 1569
2XHHW-2 XLPE (o EPR) 90 °C dieléctricoTermoestable polietileno reticulado (XHHW-2) o caucho de etileno-propileno (EPR) nominal +90 °C húmedo/secoUL 44
33 × simétrico cobre desnudo tierrasTres cobre desnudo tierra hilos nestled a 120° intervals en el intersticios de los conductores para equilibrado falla & VFD en modo común retornoUL 2225
4Continuously welded corrugated Al (CWCMC)Seamless seam-welded y corrugated aluminio tubo formando un 100 % gas-, vapour- y liquid-impervious metálico barreraUL 2225
5Aceite, chemical & UV PVC / CPE cubierta exterior-40 °C retardante de la llama (IEEE 1202 / FT4), Resistente al aceite I & II negro polymeric cubierta exteriorUL 2225

600 V / 1000 V MC-HL Potencia & VFD Cable (14 AWG a 750 MCM — 3 Fase + 3 Tierras simétricas)

XHHW-2 XLPE aislado trifásico potencia y inversor alimentador cable para Class I Div. 1 & 2 peligroso emplazamientos.

2.4 kV / 5 kV / 15 kV MV MC-HL (EPR Aislado, Apantallado)

De media tensión cobre-cinta-apantallado EPR + welded corrugated aluminio cubierta MC-HL para costa afuera y refinery MV distribución.

Datos técnicos

Valores nominales y límites de servicio

Valores típicos: Valores típicos para este tipo de cable, basados en UL 2225 / UL 1569 / NEC Art. 330 & 501. Los valores de su pedido se confirman en la ficha técnica y la oferta.

Eléctricos

Tensión nominal
600 V / 1,000 V / 2,000 V VFD (más 5 kV & 15 kV MV serie)
Dieléctrico ensayo & cubierta presión ensayo
3.5 kV AC dieléctrico + 100 % continuo pneumatic/eddy-corriente weld integridad ensayo

Térmicos

Conductor temperatura capacidad nominal
+90 °C húmedo o seco · +130 °C emergencia overload · +250 °C cortocircuito
Installation & operating temperatura
-40 °C en frío impacto & en frío curvatura a +90 °C continuo

Mecánicos

Radio mínimo de curvatura
7 × OD (fijo training) · 12 × OD (tracción)
Aplastamiento & impacto resistencia
Passes UL 2225 severo Class I Div. 1 aplastamiento & impacto tests (comparable a rigid acero conducto)

Resistencia

Imperviousness a gas, vapour & liquids
Seamless welded aluminio tubo blocks hidrocarburos migración y agua ingress
Resistencia a la llama y al aceite
UL 1685 / IEEE 1202 / CSA FT4 70,000 BTU/hr bandeja llama · Resistente al aceite I & II

Normas de referencia

Governing standards
UL 2225, UL 1569, UL 1277, CSA C22.2 Sin. 123 & NEC Articles 330, 501, 505
Marino & costa afuera approvals
US Coast Guard (USCG), ABS & IEEE 45 / API RP 14F compliant

Identificación

Identificación de conductores de fase
Negro, Blanco, Rojo (o numerados / ICEA Method 1/4) + 3 desnudo tierras
Color de la cubierta exterior
Negro (o HL/VFD franja identificación)

Dimensiones

13 estándar configuraciones (MC-HL Potencia)

Nominal dimensions, cobre peso, total masa y eléctrico parameters para MC-HL Potencia según UL 2225 / UL 1569 / NEC Art. 330 & 501 .

Dimensions & masses
Designación3 Fase + 3 Dividido TierraTierra AWG / NEC 90°C unØ ext. nom.
mm
Cobre
kg/km
Total masa ≈
kg/km
Radio mín. curvatura
mm
Consulta
MC-HL Potencia tamaño schedule
MC-HL 3C 14 AWG3C × 14 AWG + 3G3×18 AWG Gd · 25 A14.2068.0235.099.4
MC-HL 3C 12 AWG3C × 12 AWG + 3G3×16 AWG Gd · 30 A15.20108.0285.0106.4
MC-HL 3C 10 AWG3C × 10 AWG + 3G3×14 AWG Gd · 40 A16.80172.0370.0117.6
MC-HL 3C 8 AWG3C × 8 AWG + 3G3×14 AWG Gd · 55 A19.60248.0510.0137.2
MC-HL 3C 6 AWG3C × 6 AWG + 3G3×12 AWG Gd · 75 A22.10395.0710.0154.7
MC-HL 3C 4 AWG3C × 4 AWG + 3G3×12 AWG Gd · 95 A25.40602.0990.0177.8
MC-HL 3C 2 AWG3C × 2 AWG + 3G3×10 AWG Gd · 130 A28.70955.01,430.0200.9
MC-HL 3C 1/0 AWG3C × 1/0 AWG + 3G3×10 AWG Gd · 170 A33.801,455.02,060.0236.6
MC-HL 3C 2/0 AWG3C × 2/0 AWG + 3G3×8 AWG Gd · 195 A36.601,875.02,550.0256.2
MC-HL 3C 4/0 AWG3C × 4/0 AWG + 3G3×6 AWG Gd · 260 A42.402,975.03,890.0296.8
MC-HL 3C 250 MCM3C × 250 MCM + 3G3×6 AWG Gd · 290 A46.203,415.04,460.0323.4
MC-HL 3C 350 MCM3C × 350 MCM + 3G3×4 AWG Gd · 350 A51.604,800.06,050.0361.2
MC-HL 3C 500 MCM3C × 500 MCM + 3G3×4 AWG Gd · 430 A58.406,600.08,180.0408.8
  • Valores típicos para este tipo de cable; las dimensiones y pesos de su pedido se confirman en la oferta.
  • Dimensions y tolerances conform a UL 2225 / UL 1569 / NEC Art. 330 & 501 .

Calidad y homologaciones

Ensayos e inspección

Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.

  1. ConductorCuerda clase 5
  2. Ensayo de chispa100 % en línea
  3. CableadoConductores, tierra, rellenos
  4. Extrusión de cubiertaInterior, trenza / pantalla, exterior
  5. Ensayos eléctricosTensión CA, resistencia
  6. DimensionesDE, espesor de pared
  7. Documentos de inspección y expediciónTambor y expedición
Ensayos e inspecciónValor de ensayo / referenciaFrecuencia
Ensayos de rutina
3.5 kV AC dieléctrico + 100 % eddy-corriente & presión weld ensayoCero eléctrico breakdown; 100 % estanco al gas aluminio weld seam100 % de enrolladores
Ensayos por muestreo
UL 2225 severo aplastamiento/impacto & -40 °C en frío impacto ensayoPasses Class I Div. 1 mecánico aplastamiento & ártico impactoCada batch
IEEE 1202 / UL 1685 70,000 BTU/hr llama & gas-tightness ensayoUL 2225 Listed Type MC-HLCalificación de tipo

Certificado de inspección

Emitido con cada tambor, con los resultados de los ensayos de rutina de esa longitud.

Homologaciones del producto

UL 2225 Listed Type MC-HLUL 1569 Type MC & UL 1277NEC Class I, II, III Div. 1 & 2 (Zona 1 & 2)USCG & ABS Costa afuera HomologadoIEEE 1202 / CSA FT4

Certificados de la empresa

ISO 9001ISO 14001ISO 45001Homologación VDEUL / cULCE · LVD / EMC

Marcado y suministro

Pedido y entrega

Marcado de la cubierta

TEBAOFLEX (UL) TYPE MC-HL [3/C AWG + 3 SYM GND] XHHW-2 600V/1000V VFD CWCMC - 40C OIL RES II SUN RES IEEE 1202 FT4 [lot/ft]
Forma de suministro
No-returnable wooden tambores, export enrolladores o shrink-envuelto coils
Estándar tambor pasos
100 m · 250 m · 500 m · 1000 m
Pedido mínimo
200 m (stock tamaños) · 500 m (a medida pasos)
Plazo de entrega
2–3 weeks ex-trabaja
Incoterms
EXW, FOB, CIF, DAP

Documentación técnica

Descargas

Revisión
2026-10-20
Actualizado
2026-10-20

Preguntas frecuentes

Las primeras preguntas de ingeniería

¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.

What makes Type MC-HL (UL 2225) fundamentally different de estándar Type MC o TECK90?
Estándar Type MC (UL 1569) y TECK90 uso un interlocked helicoidal metal pelado armadura, el cual has microscopic spiral seams y está restricted bajo el US NEC a Class I División 2. Type MC-HL (UL 2225) forma un sólido aluminio pelado en un tubo, continuously TIG/laser welds el longitudinal seam y annularly corrugates it (CWCMC). Because el welded metálico cubierta está 100 % gas-, vapour- y liquid-impervious y passes rigid-conducto-nivel aplastamiento tests, NEC 501.10(un)(1)(c) permits MC-HL en Class I División 1 (y Zona 1) peligroso emplazamientos.
Why está MC-HL con 3 simétrico conductores de tierra el gold estándar para VFD (Variable Frecuencia Accionamiento) motor alimentadores?
IGBT inverters generate rápido-rising PWM tensión pulses that induce de alta frecuencia en modo común corrientes y radiated EMI . El 360° sólido welded aluminio tubo actúa como un unbroken Faraday cage con ultra-Baja impedancia de transferencia, mientras el tres cobre desnudo tierra hilos colocados a 120° en el fase intersticios cancel magnetic unbalance y retorno en modo común corrientes simétricamente al accionamiento.
How much installation labour does MC-HL save compared con rigid acero galvanizado conducto en Class I Div. 1?
Campo studies en petrochemical y LNG projects show that running MC-HL en abierto escalerilla cable bandejas portacables con UL 2225 barrera prensaestopas reduce total installed cost por 40 % a 60 % compared con threading, flexión, tracción y pouring explosion-proof seals en rigid galvanizado conducto.
CAN MC-HL be buried directly subterráneo o installed en costa afuera platforms?
Yes. El impervious welded aluminio cubierta combinado con el Resistente al aceite II / Luz solar Resistente cubierta exterior de PVC o CPE está listed para directo burial, concrete encasement, abierto cable bandejas portacables y USCG/ABS costa afuera marino decks.

Solicitar presupuesto

Solicite una oferta técnica para MC-HL Power

La selección y los datos de aplicación se copian al formulario de consulta inferior.

01Medidas seleccionadas

Use + Añadir junto a una medida o configuración.

02Tambor y movimiento

Añada aquí las condiciones de servicio para incluirlas en su consulta.

03Mensaje para nuestros ingenieros

MC-HL Potencia Metal-Revestido Potencia Cable

Medidas seleccionadas:


Tambor y movimiento:
- Tipo de tambor: 
- Diámetro del núcleo del tambor (mm): 
- Longitud de cable en tambor (m): 
- Velocidad de desplazamiento (m/min): 
- Aceleración máxima: 
- Ciclos por hora: 
- Longitud y cantidad: 
- Temperatura ambiente: 
- Exposición (exterior, agua, aceite, abrasión): 
- País de destino: 
- Equipo y condiciones de servicio: 
Enviar por WhatsApp

Ficha técnicaSolicitar presupuesto