Instalación fija
Engineered y verified para fixed service in accordance con ITU-T G.657.A2 / IEC 60794-2-20.
Producto
Easy-Strip Retractable Micromodule Indoor Vertical Riser Fiber Optic cable (FTTX-RISER Retractable Drop Fiber) diseñado según ITU-T G.657.A2 / IEC 60794-2-20 para All-Dielectric Optical servicio en -10 °C a +60 °C, con polymeric micromodule y lsoh
Valores típicos para este tipo de cable, basados en ITU-T G.657.A2 / IEC 60794-2-20 — confirmados en la ficha técnica y oferta de su pedido.
Aplicaciones
Easy-Strip Retractable Micromodule Indoor Vertical Riser Fiber Optic cable (FTTX-RISER Retractable Drop Fiber) diseñado según ITU-T G.657.A2 / IEC 60794-2-20 para All-Dielectric Optical servicio en -10 °C a +60 °C, con polymeric micromodule y lsoh
Engineered y verified para fixed service in accordance con ITU-T G.657.A2 / IEC 60794-2-20.
Engineered y verified para hanging service in accordance con ITU-T G.657.A2 / IEC 60794-2-20.
Suitable para switchgear, control panels y equipment terminations within 10 × OD bend radius.
Use mechanical conduit o armado protection where exposed a rock fall o crushing loads.
Construcción
Shown: FTTX-RISER Retractable Drop Fiber con polymeric micromodule, lsoh cubierta exterior con embedded grp rods core aislamiento y lsoh cubierta exterior con embedded grp rods core aislamiento.
| # | Capa | Material y referencia |
|---|---|---|
| 1 | Polymeric micromodule | Polymeric micromodule assembly per ITU-T G.657.A2 / IEC 60794-2-20ITU-T G.657.A2 / IEC 60794-2-20 |
| 2 | LSOH cubierta exterior con embedded GRP rods core aislamiento | Extruded LSOH cubierta exterior con embedded GRP rods dielectric (continuous layer)ITU-T G.657.A2 / IEC 60794-2-20 |
Built a ITU-T G.657.A2 / IEC 60794-2-20 con polymeric micromodule y lsoh cubierta exterior con embedded grp
Full range of metric mm² y AWG/kcmil conductor sizes per ITU-T G.657.A2 / IEC 60794-2-20
Supplied con EN 10204 3.1 routine dielectric & conductor resistance test certificate
Datos técnicos
Dimensiones
Manufactured a ITU-T G.657.A2 / IEC 60794-2-20 in single-pair, multi-pair y multi-unit constructions.
| Designación de pedido | Configuración | Ø exterior ≈ mm | Peso ≈ kg/km | Min. curvatura R fijo mm | Consulta |
|---|---|---|---|---|---|
| FTTX-RISER Retractable Drop Fiber Standard construcción Schedule (All-Dielectric Optical · −10…+60 °C) | |||||
| FTTX-RISER Retractable Drop Fiber 1×2×0.5 | 1×2×0.5 mm² | 6.4 | 58 | 52 | |
| FTTX-RISER Retractable Drop Fiber 2×2×0.5 | 2×2×0.5 mm² | 9.2 | 112 | 74 | |
| FTTX-RISER Retractable Drop Fiber 4×2×0.5 | 4×2×0.5 mm² | 11.4 | 176 | 92 | |
| FTTX-RISER Retractable Drop Fiber 8×2×0.5 | 8×2×0.5 mm² | 14.8 | 295 | 118 | |
| FTTX-RISER Retractable Drop Fiber 12×2×0.5 | 12×2×0.5 mm² | 17.6 | 420 | 141 | |
| FTTX-RISER Retractable Drop Fiber 1×2×1.0 | 1×2×1.0 mm² | 7.6 | 86 | 61 | |
| FTTX-RISER Retractable Drop Fiber 2×2×1.0 | 2×2×1.0 mm² | 11.0 | 168 | 88 | |
| FTTX-RISER Retractable Drop Fiber 4×2×1.0 | 4×2×1.0 mm² | 13.5 | 264 | 108 | |
| FTTX-RISER Retractable Drop Fiber 8×2×1.0 | 8×2×1.0 mm² | 17.9 | 465 | 143 | |
| FTTX-RISER Retractable Drop Fiber 1×2×1.5 | 1×2×1.5 mm² | 8.5 | 114 | 68 | |
| FTTX-RISER Retractable Drop Fiber 4×2×1.5 | 4×2×1.5 mm² | 15.2 | 348 | 122 | |
| FTTX-RISER Retractable Drop Fiber 12×2×1.5 | 12×2×1.5 mm² | 23.4 | 860 | 187 | |
| Sección del conductor | R₂₀ CC máx. Ω/km | Cap. mutua ≈ nF/km | Inductancia ≈ mH/km |
|---|---|---|---|
| 0.50 mm² (7/0.30 mm · AWG 20) | 39.00 | 115 | 0.65 |
| 0.75 mm² (7/0.37 mm · AWG 18) | 26.00 | 120 | 0.62 |
| 1.00 mm² (7/0.43 mm · AWG 17) | 19.50 | 125 | 0.60 |
| 1.50 mm² (7/0.53 mm · AWG 16) | 13.30 | 135 | 0.58 |
| 2.50 mm² (7/0.67 mm · AWG 14) | 7.98 | 145 | 0.55 |
Calidad y homologaciones
Ensayos de rutina en cada longitud de fabricación, ensayos de muestreo y tipo por lote — documentados en un certificado EN 10204 3.1.
| Ensayos e inspección | Valor de ensayo / referencia | Frecuencia |
|---|---|---|
| Ensayos de rutina | ||
| conductor DC resistance & dimensional verification (ITU-T G.657.A2 / IEC 60794-2-20) | DC resistance at 20 °C y geometry within ITU-T G.657.A2 / IEC 60794-2-20 class limits | Every manufactured drum / spool |
| Routine dielectric / spark / structural integrity test (ITU-T G.657.A2 / IEC 60794-2-20) | Zero breakdown o structural defect over full production length | Every manufactured drum / spool |
| Ensayos por muestreo | ||
| Thermal aging, mechanical & material qualification (ITU-T G.657.A2 / IEC 60794-2-20) | Full compliance con ITU-T G.657.A2 / IEC 60794-2-20 across −10…+60 °C | Type qualification & periodic sample audit |
Marcado y suministro
Marcado de la cubierta
Documentación técnica
Preguntas frecuentes
¿No está aquí? Envíenos su plano — un ingeniero responde en 2 horas laborables.
Solicitar presupuesto
La selección y los datos de aplicación se copian al formulario de consulta inferior.
Use + Añadir junto a una medida o configuración.
Añada aquí las condiciones de servicio para incluirlas en su consulta.