Commande & signal câbleISO 14644-1 Class 1 CleanroomS 776 & S 780 C BlindéClass 6 Continu Chaîne porte-câbles

SABclean S 776 / S 780 C Faible-Outgassing Cleanroom SoupleISO 14644-1 Class 1 faible-outgassing Class 6 TPE/PUR cleanroom chaîne porte-câbles Câble de commande

ISO 14644-1 Class 1 faible-outgassing Class 6 TPE/PUR cleanroom chaîne porte-câbles Câble de commande

Homologué
Écran CEM
Conception faible CEM
Tresse anti-torsion
Désignation de commande
SABclean S 776 / S 780 C 7G0.5
Ø ext. ≈
8.00 mm
Épaisseur de paroi
1.25 mm
Total masse ≈
131.5 kg/km
Min. courbure R (fixe)
56 mm
Toutes les dimensions (24)
Réponse technique sous 2 heures ouvréesTourets d’exportation coupés à la longueurCertificat EN 10204 3.1 par touret
Cleanroom classe
ISO Class 1
Fraunhofer IPA ISO 14644-1
Outgassing
VOC/SVOC essayé
Ultra-faible molecular outgassing
Tension assignée
300/500 V
≤ 0.34 mm²: 300/300 V
Conducteur
Cu Class 6
Super-fin chaîne porte-câbles toronnage
Versions
S 776 & S 780 C
Non blindé ou Sn-Cu tresse ('C')
Temp.. gamme
-40…+80 °C
5–7.5 × OD chaîne porte-câbles courbure

Valeurs types pour ce type de câble, basés sur ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles Spécification — confirmées dans la fiche technique et le devis de votre commande.

Applications

SABclean S 776 / S 780 C convient-il à votre machine ?

SABclean S 776 (non blindé) et S 780 C (blindé) continu-flexion cleanroom Câble de commande (300/500 V, -40 à +80 °C) pour ISO 14644-1 Class 1 cleanrooms, featuring IEC 60228 Class 6 conducteurs en cuivre, TPE isolation, et un faible-outgassing matte TPE/PUR gaine.

Chaîne porte-câbles

Adapté

Class 6 toronnage, TPE conducteurs, et matte TPE/PUR gaine achieve ultra-faible particle abrasion dans cleanroom chaînes porte-câbles.

Câblage d’armoires et cellules électriques

Adapté

100 % talc-, chalk-, et silicone-libre (LABS-libre) exécution empêche outgassing (AMC) et powder release lorsque dénudage.

Liaison blindée variateur VFD vers moteur CA

Adapté

Choose SABclean S 780 C (≥ 85 % Écran tressé en cuivre étamé sur Gaine intérieure extrudée) pour servo encoders, linear moteurs, et vision stages.

Machines typesSemiconductor Wafer Handling & Robotics (ISO Class 1)Plat-Panel Display, OLED & Solar Cell CleanroomsPharmaceutical Aseptic Remplissant & Biotech AutomatisationOptique, Laser & De précision Metrology GantriesBattery Sec-Room & EV Cell Assemblage

Construction

Couche par couche

SABclean S 776 / S 780 C construction: IEC 60228 Class 6 super-fin conducteurs en cuivre nu, faible-capacitance TPE Isolation de conducteur, non-shedding non-tissé enrubannage (plus gaine intérieure + cuivre étamé tresse sur S 780 C), et faible-outgassing matte TPE/PUR gaine extérieure.

12345
Schéma sans échelle — généré à partir des données des couches
#CoucheMatériau et référence
1Super-fin Class 6 cuivreExtra-toronné fin cuivre nu fil selon IEC 60228 / DIN VDE 0295 Class 6Built pour serré 5 × OD à 7.5 × OD flexion radii dans compact cleanroom linear stages
2Faible-outgassing TPE conducteur paroiSpécial sans halogène élastomère thermoplastique (DIN 47100 ≤ 0.34 mm² ou noir numérotés + GNYE ≥ 0.5 mm²)Mince, robuste conducteur paroi minimises câble diamètre et flexion rigidité
3Talc-libre non-tissé / gaine intérieureS 776: non-shedding non-tissé enrubannage | S 780 C: sans halogène gaine intérieure sous écranÉlimine interne séparateur powders afin que câble dénudage never contaminates le cleanroom
4Cuivre étamé tresse (S 780 C uniquement)S 780 C version: faible-angle tressé fils de cuivre étamé (≥ 85 % recouvrement optique)Élevé-flexion EMC blindage pour cleanroom servo entraînements et de précision encoders
5Faible-outgassing matte TPE/PUR gaineSpécial faible-abrasion, non-adhesive matte élastomère thermoplastique / PUR mélange (gris ou noir)Empêche stick-glissement particle génération contre PTFE/PE cleanroom câble pods

SABclean S 776 (2×0.14 à 25G1.5 mm²)

Non blindé ISO Class 1 faible-outgassing cleanroom chaîne porte-câbles commande et sensor câble

SABclean S 780 C (2×0.14 à 25G1.5 mm²)

En cuivre étamé-tresse blindé ('C') ISO Class 1 faible-outgassing cleanroom chaîne porte-câbles câble

Données techniques

Valeurs nominales et limites de service

Valeurs types: Valeurs types pour ce type de câble, basés sur ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles Spécification. Les valeurs de votre commande sont confirmées dans la fiche technique et le devis.

Électriques

Tension assignée U0/U
300/500 V (≥ 0.5 mm²) · 300/300 V (0.14–0.34 mm²)
AC diélectrique essai tension
2,000 V AC (≥ 0.5 mm²) · 1,500 V AC (≤ 0.34 mm²)
EMC écran (S 780 C)
Tressé fil de cuivre étamé (≥ 85 % recouvrement)
Résistance d'isolement
≥ 100 MΩ·km à +20 °C

Thermiques

Continu flexion temp..
-40 °C à +80 °C
Fixe installation temp..
-50 °C à +80 °C

Mécaniques

Cleanroom particle classe
ISO 14644-1 Air Cleanliness Class 1
Toronnage du conducteur
IEC 60228 Class 6 super-fin cuivre
Rayon de courbure minimal (chaîne)
Modèle 5 × OD (S 776) · 7.5 × OD (S 780 C)
Rayon de courbure minimal (fixe)
3 × OD (S 776) · 4 × OD (S 780 C)

Résistance

Outgassing & LABS/PWIS
Ultra-faible VOC/SVOC outgassing · LABS/PWIS -libre
Sans halogène & huile résistance
IEC 60754-1/2 sans halogène · EN 60811-404 huile pass
Cleanroom disinfectant wipe
Résistant à IPA, H₂O₂ & quaternary ammonium

Normes de référence

Cleanroom qualification
ISO 14644-1 Class 1 & ISO 14644-14
UL / CSA reference
UL AWM Style 21198 / CSA (jusqu'à 80 °C, 300/600 V)
RoHS & REACH
RoHS 3 & REACH compliant

Identification

Couleur de la gaine extérieure
Cleanroom gris (RAL 7001/7035) ou matte noir
Marquage en surface
TEBAOFLEX SABclean S 776 [ou S 780 C] [n×mm²] ISO CLASS 1
Code tarifaire douanier (HS)
8544.49

Dimensions

24 standard configurations (SABclean S 776 / S 780 C)

Engineering dimensions, conducteur toronnage, masse et électrique ratings pour SABclean S 776 / S 780 C selon ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles Spécification.

Dimensions et masses
Désignation de commandeSection transversale / sectionConducteur exécutionParoi ≈
mm
Ø ext. ≈
mm
Métal
kg/km
Masse ≈
kg/km
Min. courbure R
fixe mm
Demande
Standard SABclean S 776 / S 780 C configurations
SABclean S 776 / S 780 C 4×0.254×0.25 mm²Class 6 Cu (0.25 mm²)1.256.3032.375.244
SABclean S 776 / S 780 C 8×0.258×0.25 mm²Class 6 Cu (0.25 mm²)1.257.7046.9110.954
SABclean S 776 / S 780 C 12×0.2512×0.25 mm²Class 6 Cu (0.25 mm²)1.459.4062.6158.066
SABclean S 776 / S 780 C 18×0.2518×0.25 mm²Class 6 Cu (0.25 mm²)1.4510.7081.7205.375
SABclean S 776 / S 780 C 4×0.344×0.34 mm²Class 6 Cu (0.34 mm²)1.256.6036.883.846
SABclean S 776 / S 780 C 8×0.348×0.34 mm²Class 6 Cu (0.34 mm²)1.258.1055.3126.257
SABclean S 776 / S 780 C 12×0.3412×0.34 mm²Class 6 Cu (0.34 mm²)1.459.9074.8180.769
SABclean S 776 / S 780 C 3G0.53G0.5 mm²Class 6 Cu (0.5 mm²)1.256.5037.883.446
SABclean S 776 / S 780 C 4G0.54G0.5 mm²Class 6 Cu (0.5 mm²)1.257.0044.497.349
SABclean S 776 / S 780 C 7G0.57G0.5 mm²Class 6 Cu (0.5 mm²)1.258.0062.4131.556
SABclean S 776 / S 780 C 12G0.512G0.5 mm²Class 6 Cu (0.5 mm²)1.4510.6095.8217.174
SABclean S 776 / S 780 C 18G0.518G0.5 mm²Class 6 Cu (0.5 mm²)1.4512.10130.0288.185
SABclean S 776 / S 780 C 3G0.753G0.75 mm²Class 6 Cu (0.75 mm²)1.256.9046.497.848
SABclean S 776 / S 780 C 4G0.754G0.75 mm²Class 6 Cu (0.75 mm²)1.257.5055.8116.652
SABclean S 776 / S 780 C 7G0.757G0.75 mm²Class 6 Cu (0.75 mm²)1.258.7081.7163.461
SABclean S 776 / S 780 C 12G0.7512G0.75 mm²Class 6 Cu (0.75 mm²)1.4511.40127.4267.880
SABclean S 776 / S 780 C 18G0.7518G0.75 mm²Class 6 Cu (0.75 mm²)1.4513.20177.1365.392
SABclean S 776 / S 780 C 3G13G1 mm²Class 6 Cu (1 mm²)1.257.3055.1112.751
SABclean S 776 / S 780 C 4G14G1 mm²Class 6 Cu (1 mm²)1.257.9066.8134.255
SABclean S 776 / S 780 C 7G17G1 mm²Class 6 Cu (1 mm²)1.259.20100.3191.764
SABclean S 776 / S 780 C 12G112G1 mm²Class 6 Cu (1 mm²)1.4512.20159.1319.885
SABclean S 776 / S 780 C 4G1.54G1.5 mm²Class 6 Cu (1.5 mm²)1.259.1090.4179.864
SABclean S 776 / S 780 C 7G1.57G1.5 mm²Class 6 Cu (1.5 mm²)1.2510.70139.3262.975
SABclean S 776 / S 780 C 12G1.512G1.5 mm²Class 6 Cu (1.5 mm²)1.4514.30224.3445.1100
  • Valeurs types pour ce type de câble ; les dimensions et masses de votre commande sont confirmées dans le devis.
  • Extérieur diameters et weights sont nominal engineering values pour SABclean S 776 / S 780 C subject à standard manufacturing tolerances selon ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles Spécification.

Qualité et homologations

Essais et contrôle

Essais individuels sur chaque longueur produite, essais sur prélèvements et de type par lot — documentés sur un certificat EN 10204 3.1.

  1. ConducteurToronnage classe 5
  2. Essai à l’étincelle100 % en ligne
  3. AssemblageConducteurs, terre, bourrages
  4. GainageIntérieure, tresse / écran, extérieure
  5. Essais électriquesTension CA, résistance
  6. DimensionsDE, épaisseur de paroi
  7. Documents de contrôle et expéditionTouret et expédition
Essais et contrôleValeur d’essai / référenceFréquence
Essais individuels
Diélectrique spark / Haute tension withstand essai100 % dans-line spark et AC/DC diélectrique withstand selon ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles SpécificationChaque longueur fabriquée
Conducteur DC résistance & continuité contrôleAu sein de maximal 20 °C résistance limit spécifié pour SABclean S 776 / S 780 CChaque spool ou tambour longueur
Essais sur prélèvements
Isolation résistance & dimensional verificationÉpaisseur de paroi, concentricity et isolation résistance selon ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles SpécificationPar lot de production
Environmental, mécanique & EMC qualificationQualified à ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles Spécification thermique, mécanique et environmental performance criteriaQualification de type

Certificat de contrôle

Délivré avec chaque touret, indiquant les résultats des essais individuels pour cette longueur.

Homologations du produit

ISO 14644-1 Air Cleanliness Class 1 / DIN VDE 0250 Cleanroom Chaîne porte-câbles SpécificationCE (2014/35/EU) & RoHS 3 (2015/863/EU) CompliantREACH SVHC Conformité Verified

Certificats de l’entreprise

ISO 9001ISO 14001ISO 45001Homologation VDEUL / cULCE · LVD / EMC

Marquage et livraison

Commande et livraison

Marquage de la gaine

TEBAOFLEX SABclean S 776 / S 780 C 7G0.5 ISO 14644-1 CLASS 1 CLEANROOM
Conditionnement de livraison
Export wooden tambours, tactical enrouleurs ou coils
Standard pas
100 m · 500 m · 1000 m (ou sur mesure coupure pas)
Commande minimale
100 m (stock sections) · 300–500 m (sur mesure exécution)
Délai de livraison
2–4 weeks ex-travaille
Incoterms
EXW, FOB, CIF, DAP

Documents techniques

Téléchargements

Révision
2026-10-20
Mise à jour
2026-10-20

FAQ

Les premières questions des ingénieurs

Une autre question ? Envoyez votre plan — un ingénieur répond sous 2 heures ouvrées.

Why standard PUR ou PVC chaîne porte-câbles câbles fail ISO 14644-1 Class 1 cleanroom qualification?
Standard chaîne porte-câbles câbles fail dans semiconductor cleanrooms pour trois reasons: (1) glossy jackets exhibit 'stick-glissement' frottement contre chaîne porte-câbles crossbars, shedding sous-micron polymère usure particles; (2) interne talcum séparateur powder escapes du câble ends; et (3) plasticizers et cyclic siloxanes outgas comme Airborne Molecular Contamination (AMC) that fogs wafer optics. SABclean S 776 / S 780 C élimine tous trois via un talc-libre conducteur et un faible-outgassing matte TPE/PUR gaine.
What est le difference entre SABclean S 776 et SABclean S 780 C?
SABclean S 776 est le non blindé version pour compact 5 × OD courbure radii dans miniature actuators, vannes, et discrete I/O. SABclean S 780 C ajoute un Gaine intérieure extrudée et un ≥ 85 % tresse en fils de cuivre étamé écran ('C', 7.5 × OD rayon de courbure) pour EMC -critical codeur, vision, et servo commande circuits.
Est SABclean S 776 / S 780 C silicone-libre (LABS/PWIS -libre)?
Yes. À la fois S 776 et S 780 C sont fabriqué libre de paint-wetting impairment substances (LABS/PWIS -libre) et libre de volatile siloxanes.
Lorsque should I choose SABclean S 776 / S 780 C vs. Besilen ESD Câble de commande?
Choose SABclean S 776 / S 780 C pour continu à grande vitesse chaînes porte-câbles (millions de cycles à 5–7.5 × OD, -40 à +80 °C) où ultra-faible VOC outgassing et zéro silicone sont requis. Choose Besilen ESD Câble de commande lorsque you need +180 °C chaleur résistance ou un actifs ESD-dissipative (10⁴–10⁷ Ω) gaine extérieure.

Demander un devis

Obtenez un devis technique pour SABclean S 776 / S 780 C

Votre sélection et les détails de l’application sont copiés dans le formulaire ci-dessous.

01Dimensions sélectionnées

Utilisez + Ajouter à côté d’une dimension ou configuration.

02Enrouleur et mouvement

Ajoutez ici vos conditions de service pour les inclure dans votre demande.

03Message pour nos ingénieurs

SABclean S 776 / S 780 C Faible-Outgassing Cleanroom Souple

Dimensions sélectionnées:


Enrouleur et mouvement:
- Type d’enrouleur: 
- Diamètre du noyau du tambour (mm): 
- Longueur de câble sur tambour (m): 
- Vitesse de déplacement (m/min): 
- Accélération maximale: 
- Cycles par heure: 
- Longueur et quantité: 
- Température ambiante: 
- Exposition (extérieur, eau, huile, abrasion): 
- Pays de destination: 
- Équipement et conditions de service: 
Envoyer par WhatsApp

Fiche techniqueDemander un devis