固定敷设
多-线对船用仪表, 主 engine exhaust/带有 sensors, cargo radar gauging 及 ECR marshalling.
产品主图
本电缆型号的典型值(依据 JIS C 3410 / IEC 60092-376)——具体订单参数将在技术规格书与报价单中确认。
应用工况
分相线对/线芯-屏蔽 250 V 船用船用仪表电缆 family 至 JIS C 3410 (`MPY-S`, `MPYC-S`, `MPYCY-S`). 每根 +90 °C EP -橡胶线对为绕包于其独立铜/铝-金属箔屏蔽层 (`-S`) 至 eliminate 通道间串扰。
多-线对船用仪表, 主 engine exhaust/带有 sensors, cargo radar gauging 及 ECR marshalling.
分相线对屏蔽层加外线丝-编织层铠装 (MPYC-S / MPYCY-S) suppress 同时间-线对串扰及 VFD noise.
电缆结构
图示: MPYCY-S 4×2×1.25 mm² — 7 线绞合铜导体, +90 °C EP -橡胶线对绝缘 ('P'), 分相铜/铝-Mylar 屏蔽层 + 排流线丝于每根线对 ('-S'), PVC 内衬层 ('Y'), 线丝-编织层铠装 ('C') 及黑色 PVC 外 oversheath ('Y').
| # | 结构层 | 材料与参考标准 |
|---|---|---|
| 1 | 绞合退火铜导体 | 7 线圆形绞合退火铜至 JIS C 3102 / IEC 60228 Class 2JIS C 3410 / IEC 60228 Cl. 2 |
| 2 | EP -橡胶线对绝缘 (P) | +90 °C 交联乙丙橡胶 (EPR) 对绞成线对配线对识别JIS C 3410 · IEC 60092-360 EPR |
| 3 | 线对分屏蔽层 (-S) | 铜绕包带/编织层或铝-聚酯绕包带 + 镀锡排流线丝 + 数字编号隔离绕包带包覆于每根分相线对JIS C 3410 |
| 4 | Vinyl 护套 (Y) | 阻燃 PVC 外护套 (于 MPY-S) 或内衬层护套 (于 MPYC-S / MPYCY-S)JIS C 3410 |
| 5 | 可选金属丝编织层 + oversheath (C / CY) | 非铠装 (MPY-S), 镀锌钢/铜金属丝编织层 (MPYC-S), 或金属丝编织层 + PVC 外 oversheath (MPYCY-S)JIS C 3410 · IEC 60332-3-22 类别。 |
非铠装多-线对船用仪表电缆用于 bridge consoles 及干燥 ECR cabinets
增设外露镀锌钢或铜金属丝编织层铠装包覆于线对-屏蔽成缆缆芯
全 engine-room 及甲板规范配分相线对屏蔽层, 金属丝编织层铠装及外 PVC oversheath
技术数据
规格尺寸
Typical JIS C 3410 / IEC 60092-376 外直径限制, 铜 content 及电缆重量。
| 订货型号 | 芯数 × mm² | AWG ≈ | 最小外径 mm | 最大外径 mm | 铜重 kg/km | 近似重量 ≈ kg/km | 最小弯曲半径 mm | 询价 |
|---|---|---|---|---|---|---|---|---|
| n × 2 × 0.75 mm² 分相屏蔽线对 (MPY-S / MPYC-S / MPYCY-S) | ||||||||
| MPYCY-S 1×2×0.75 | 1×2×0.75 | 18 | 10.9 | 11.8 | 22 | 195 | 71 | |
| MPYCY-S 2×2×0.75 | 2×2×0.75 | 18 | 14.0 | 15.2 | 42 | 320 | 91 | |
| MPYCY-S 4×2×0.75 | 4×2×0.75 | 18 | 16.4 | 17.8 | 82 | 465 | 107 | |
| MPYCY-S 7×2×0.75 | 7×2×0.75 | 18 | 19.1 | 20.8 | 140 | 665 | 125 | |
| MPYCY-S 12×2×0.75 | 12×2×0.75 | 18 | 24.1 | 26.2 | 238 | 1,020 | 157 | |
| MPYCY-S 19×2×0.75 | 19×2×0.75 | 18 | 28.3 | 30.8 | 375 | 1,450 | 185 | |
| n × 2 × 1.25 mm² 分相屏蔽线对 (MPY-S / MPYC-S / MPYCY-S) | ||||||||
| MPYCY-S 1×2×1.25 | 1×2×1.25 | 16 | 11.6 | 12.6 | 32 | 228 | 76 | |
| MPYCY-S 2×2×1.25 | 2×2×1.25 | 16 | 15.1 | 16.4 | 62 | 378 | 98 | |
| MPYCY-S 4×2×1.25 | 4×2×1.25 | 16 | 17.8 | 19.4 | 122 | 565 | 116 | |
| MPYCY-S 7×2×1.25 | 7×2×1.25 | 16 | 21.0 | 22.8 | 212 | 825 | 137 | |
| MPYCY-S 12×2×1.25 | 12×2×1.25 | 16 | 26.7 | 29.0 | 360 | 1,290 | 174 | |
| n × 2 × 1.50 mm² 分相屏蔽线对 (MPY-S / MPYC-S / MPYCY-S) | ||||||||
| MPYCY-S 1×2×1.5 | 1×2×1.5 | 16 | 12.0 | 13.0 | 37 | 244 | 78 | |
| MPYCY-S 2×2×1.5 | 2×2×1.5 | 16 | 15.6 | 17.0 | 72 | 408 | 102 | |
| MPYCY-S 4×2×1.5 | 4×2×1.5 | 16 | 18.6 | 20.2 | 142 | 618 | 121 | |
| MPYCY-S 7×2×1.5 | 7×2×1.5 | 16 | 21.9 | 23.8 | 248 | 912 | 143 | |
| MPYCY-S 12×2×1.5 | 12×2×1.5 | 16 | 27.8 | 30.2 | 422 | 1,435 | 181 | |
| 标称截面 mm² | AWG ≈ | 最大直流电阻 20 °C, Ω/km | 单根线对/线芯 30 °C, | 多-成缆线芯束 30 °C, |
|---|---|---|---|---|
| 0.75 | 18 | 26 | 12.0 | 10.0 |
| 1.25 | 16 | 15.6 | 18.0 | 15.0 |
| 1.5 | 16 | 13.3 | 23.0 | 18.0 |
卷筒校核
基于技术参数的初步校核。工程师将在报价时结合卷筒几何尺寸、加速度与拉力做最终确认。
质量与认证
每根出厂长度均经例行试验,按批次进行抽样与型式试验,并随附 EN 10204 3.1 检验证书。
| 测试与检验 | 试验值/参考标准 | 频次 |
|---|---|---|
| 例行试验 | ||
| AC 耐压试验 | 1.5 kV AC (50 Hz) | 每根生产长度 |
| 导体直流电阻 | IEC 60228 / JIS C 3410 / IEC 60092-376 (裸铜) | 每根生产长度 |
| 抽样试验 | ||
| 垂直火焰蔓延试验 | IEC 60332-1-2 / EN 60332-1-2 | 每生产批次 |
| 绝缘 & 护套材料 physical properties | JIS C 3410 / IEC 60092-376 | 型式认可 |