本电缆型号的典型值(依据 JIS C 3410 / IEC 60092-376)——具体订单参数将在技术规格书与报价单中确认。
应用工况
总-屏蔽 250 V 船用船用控制及仪表电缆 family 至 JIS C 3410 (`MPYS`, `MPYCS`, `MPYCYS`) 结合 +90 °C EP -橡胶线芯及总静电屏蔽层 (`S`) 配非铠装, 编织或外覆护套保护。
船用自动化, engine governor 遥测, bridge alarm panels 及 tank-排线仪表。
专用总静电屏蔽层 ('S') 隔离控制信号自船用 propulsion VFD harmonics.
电缆结构
图示: MPYCYS 7×1.5 mm² — 7 线绞合铜导体, +90 °C EP -橡胶线芯 ('P'), 总铜/铝-Mylar 静电屏蔽层配排流线丝 ('S'), PVC 内护套 ('Y'), 线丝-编织层铠装 ('C') 及黑色阻燃 PVC 外 oversheath ('Y').
| # | 结构层 | 材料与参考标准 |
|---|---|---|
| 1 | 绞合退火铜导体 | 7 线圆形绞合退火铜至 JIS C 3102 / IEC 60228 Class 2JIS C 3410 / IEC 60228 Cl. 2 |
| 2 | EP -橡胶线芯绝缘 (P) | +90 °C 交联乙丙橡胶 (EPR) 配 sequential 数字 printingJIS C 3410 · IEC 60092-360 EPR |
| 3 | 总静电屏蔽层 (S) | 总铜绕包带/编织层或铝-聚酯绕包带配镀锡铜排流线丝包覆于成缆线芯束JIS C 3410 |
| 4 | Vinyl 护套 (Y) | 阻燃 PVC 外护套 (于 MPYS) 或内衬层护套 (于 MPYCS / MPYCYS)JIS C 3410 |
| 5 | 可选金属丝编织层 + oversheath (C / CY) | 非铠装 (MPYS), 镀锌钢/铜金属丝编织层 (MPYCS), 或金属丝编织层 + PVC 外 oversheath (MPYCYS)JIS C 3410 · IEC 60332-3-22 类别。 |
用于干燥 wheelhouse, bridge console 及 ECR 仪表 racks 需要总 EMI 屏蔽
增设外露镀锌钢或铜金属丝编织层铠装包覆于总屏蔽电缆
全 engine-room 及甲板规范配总屏蔽层, 金属丝编织层铠装及 sealed PVC oversheath
技术数据
规格尺寸
Typical JIS C 3410 / IEC 60092-376 外直径限制, 铜 content 及电缆重量。
| 订货型号 | 芯数 × mm² | AWG ≈ | 最小外径 mm | 最大外径 mm | 铜重 kg/km | 近似重量 ≈ kg/km | 最小弯曲半径 mm | 询价 |
|---|---|---|---|---|---|---|---|---|
| 0.75 mm² 总屏蔽船用控制 (MPYS / MPYCS / MPYCYS) | ||||||||
| MPYCYS 2×0.75 | 2×0.75 | 18 | 10.7 | 11.6 | 22 | 192 | 70 | |
| MPYCYS 4×0.75 | 4×0.75 | 18 | 11.8 | 12.8 | 38 | 240 | 77 | |
| MPYCYS 7×0.75 | 7×0.75 | 18 | 13.2 | 14.4 | 62 | 312 | 86 | |
| MPYCYS 12×0.75 | 12×0.75 | 18 | 16.2 | 17.6 | 102 | 462 | 106 | |
| MPYCYS 19×0.75 | 19×0.75 | 18 | 18.5 | 20.1 | 156 | 628 | 121 | |
| 1.25 mm² 总屏蔽船用控制 (MPYS / MPYCS / MPYCYS) | ||||||||
| MPYCYS 2×1.25 | 2×1.25 | 16 | 11.4 | 12.4 | 32 | 222 | 74 | |
| MPYCYS 4×1.25 | 4×1.25 | 16 | 12.7 | 13.8 | 58 | 288 | 83 | |
| MPYCYS 7×1.25 | 7×1.25 | 16 | 14.4 | 15.6 | 98 | 386 | 94 | |
| MPYCYS 12×1.25 | 12×1.25 | 16 | 17.8 | 19.4 | 162 | 584 | 116 | |
| MPYCYS 19×1.25 | 19×1.25 | 16 | 20.5 | 22.3 | 250 | 810 | 134 | |
| 1.50 mm² 总屏蔽船用控制 (MPYS / MPYCS / MPYCYS) | ||||||||
| MPYCYS 2×1.5 | 2×1.5 | 16 | 11.7 | 12.7 | 37 | 235 | 76 | |
| MPYCYS 4×1.5 | 4×1.5 | 16 | 13.1 | 14.2 | 68 | 308 | 85 | |
| MPYCYS 7×1.5 | 7×1.5 | 16 | 14.8 | 16.1 | 115 | 418 | 97 | |
| MPYCYS 12×1.5 | 12×1.5 | 16 | 18.5 | 20.1 | 192 | 638 | 121 | |
| MPYCYS 19×1.5 | 19×1.5 | 16 | 21.3 | 23.1 | 298 | 888 | 139 | |
| MPYCYS 27×1.5 | 27×1.5 | 16 | 24.7 | 26.8 | 418 | 1,185 | 161 | |
| 2.50 mm² 总屏蔽船用控制 (MPYS / MPYCS / MPYCYS) | ||||||||
| MPYCYS 2×2.5 | 2×2.5 | 14 | 12.6 | 13.7 | 58 | 282 | 82 | |
| MPYCYS 4×2.5 | 4×2.5 | 14 | 14.2 | 15.4 | 108 | 382 | 92 | |
| MPYCYS 7×2.5 | 7×2.5 | 14 | 16.4 | 17.8 | 184 | 538 | 107 | |
| MPYCYS 12×2.5 | 12×2.5 | 14 | 20.5 | 22.3 | 310 | 832 | 134 | |
| 标称截面 mm² | AWG ≈ | 最大直流电阻 20 °C, Ω/km | 单根线对/线芯 30 °C, | 多-成缆线芯束 30 °C, |
|---|---|---|---|---|
| 0.75 | 18 | 26 | 12.0 | 10.0 |
| 1.25 | 16 | 15.6 | 18.0 | 15.0 |
| 1.5 | 16 | 13.3 | 23.0 | 18.0 |
| 2.5 | 14 | 7.98 | 30.0 | 25.0 |
卷筒校核
基于技术参数的初步校核。工程师将在报价时结合卷筒几何尺寸、加速度与拉力做最终确认。
质量与认证
每根出厂长度均经例行试验,按批次进行抽样与型式试验,并随附 EN 10204 3.1 检验证书。
| 测试与检验 | 试验值/参考标准 | 频次 |
|---|---|---|
| 例行试验 | ||
| AC 耐压试验 | 1.5 kV AC (50 Hz) | 每根生产长度 |
| 导体直流电阻 | IEC 60228 / JIS C 3410 / IEC 60092-376 (裸铜) | 每根生产长度 |
| 抽样试验 | ||
| 垂直火焰蔓延试验 | IEC 60332-1-2 / EN 60332-1-2 | 每生产批次 |
| 绝缘 & 护套材料 physical properties | JIS C 3410 / IEC 60092-376 | 型式认可 |
标识与供货
护套印字
常见问题
未涵盖您的问题?欢迎发送图纸或工况,工程师将在 2 个工作小时内回复。
获取报价
所选规格与工况将一起带入下方询价表单。