地面拖曳与移动供电
重型双层 5GM5 外护套 resists boulder 磨损及 skid-sled dragging 于露天矿坑 benches.
产品主图
20/35 kV (Umax 42 kV) 屏蔽 EPR/PCP 拖曳动力电缆用于 walking 拉铲挖掘机 &
本电缆型号的典型值(依据 DIN VDE 0250-813 / Enterprise 20/35 kV MV 拖曳)——具体订单参数将在技术规格书与报价单中确认。
应用工况
35-CHVU 为超-高中压 20/35 kV (Umax 42 kV) 柔性拖曳动力电缆 engineered 用于 mega-scale 疏绕-露天矿坑 walking 拉铲挖掘机, bucket-wheel 挖掘机, 及于-露天矿坑挤压 stations, featuring 三层共挤 HEPR/EPR 绝缘 (V)
重型双层 5GM5 外护套 resists boulder 磨损及 skid-sled dragging 于露天矿坑 benches.
Suitable 用于 large-直径电动电缆卷筒梭车及 Benninghoven/露天矿坑电缆 carriers.
Used 于半-移动式露天矿坑 perimeter skids, 电缆 bridges, 及 substation 压降 towers.
耐水 HEPR 绝缘及聚氯丁二烯护套 tolerate flooded 露天矿坑 sumps.
电缆结构
3 根 Class 5 镀锡铜相导体, 三层共挤内半导电层 + 20/35 kV HEPR/EPR 绝缘介质 (V) + 外半导电层 (H), 镀锡
| # | 结构层 | 材料与参考标准 |
|---|---|---|
| 1 | 相导体 | 细丝绞合镀锡退火铜, Class 5 符合 IEC 60228IEC 60228 Class 5 |
| 2 | 内 & 外半导电层 (H) | 洁净易剥-剥离硫化半导电弹性体层 (Halbleiterschicht)DIN VDE 0250-813 |
| 3 | 20/35 kV HEPR/EPR 绝缘介质 (V) | 高等级臭氧- 及 partial-discharge-耐受交联 EPR/HEPR 胶料DIN VDE 0207-20 / IEC 60502-2 |
| 4 | 金属相屏蔽层 (C) | 螺旋绕包镀锡铜丝/绕包带 + 间隙分裂接地导体DIN VDE 0250-813 |
| 5 | 内弹性体内衬层 | 挤压式挤包 GM1b/5GM3 内护套配抗扭转纤维纺织加强层DIN VDE 0250-813 |
| 6 | 外护套 (U) | 超重型阻燃, 油-, UV - 及抗撕裂聚氯丁二烯 5GM5DIN VDE 0207-21 |
3 屏蔽 20/35 kV 相线芯 + 3 对称间隙分裂接地导体。
可选间隙导引线芯监视线芯或单模光纤套管用于 dragline 遥测。
技术数据
规格尺寸
标称 dimensions, 铜 weights 及电气 parameters 用于 35-CHVU 符合 DIN VDE 0250-813 / Enterprise 20/35 kV MV 拖曳。
| 订货型号 | 规格配置 | 相规格 mm² | 近似外径 ≈ mm | 铜重 kg/km | 近似重量 ≈ kg/km | Min. 弯曲 R 固定敷设 mm | 询价 |
|---|---|---|---|---|---|---|---|
| 标准 35-CHVU 种配置 | |||||||
| 35-CHVU 3×35+3×16/3E 20/35 kV | 3×35 + 3×16/3E (20/35 kV) | 35 | 72.0 | 1,480 | 6,450 | 720 | |
| 35-CHVU 3×50+3×25/3E 20/35 kV | 3×50 + 3×25/3E (20/35 kV) | 50 | 76.5 | 1,980 | 7,480 | 765 | |
| 35-CHVU 3×70+3×35/3E 20/35 kV | 3×70 + 3×35/3E (20/35 kV) | 70 | 81.2 | 2,710 | 8,720 | 812 | |
| 35-CHVU 3×95+3×50/3E 20/35 kV | 3×95 + 3×50/3E (20/35 kV) | 95 | 86.5 | 3,680 | 10,350 | 865 | |
| 35-CHVU 3×120+3×70/3E 20/35 kV | 3×120 + 3×70/3E (20/35 kV) | 120 | 91.5 | 4,650 | 11,920 | 915 | |
| 35-CHVU 3×150+3×70/3E 20/35 kV | 3×150 + 3×70/3E (20/35 kV) | 150 | 96.8 | 5,560 | 13,580 | 968 | |
| 35-CHVU 3×185+3×95/3E 20/35 kV | 3×185 + 3×95/3E (20/35 kV) | 185 | 102.0 | 6,890 | 15,640 | 1,020 | |
| 规格配置 | 最大。DC R @ 20 °C Ω/km | 载流量 于 air () | 载流量 installed () | 相互 C pF/m ≈ | AC 试验 V rms |
|---|---|---|---|---|---|
| 3×35 + 3×16/3E (20/35 kV) | 0.568 | 150 | 128 | 168 | 50,000 |
| 3×50 + 3×25/3E (20/35 kV) | 0.396 | 187 | 159 | 192 | 50,000 |
| 3×70 + 3×35/3E (20/35 kV) | 0.279 | 229 | 195 | 226 | 50,000 |
| 3×95 + 3×50/3E (20/35 kV) | 0.211 | 276 | 235 | 267 | 50,000 |
| 3×120 + 3×70/3E (20/35 kV) | 0.165 | 319 | 271 | 308 | 50,000 |
| 3×150 + 3×70/3E (20/35 kV) | 0.132 | 365 | 310 | 358 | 50,000 |
| 3×185 + 3×95/3E (20/35 kV) | 0.109 | 415 | 353 | 370 | 50,000 |
质量与认证
每根出厂长度均经例行试验,按批次进行抽样与型式试验,并随附 EN 10204 3.1 检验证书。
| 测试与检验 | 试验值/参考标准 | 频次 |
|---|---|---|
| 例行试验 | ||
| 50 kV AC 绝缘介质试验 | 50 kV rms / 5 min 无 breakdown | 100 % 卷筒 |
| 局部放电试验 | ≤ 10 pC 在 1.73 U0 (35 kV) | 100 % 卷筒 |
| 抽样试验 | ||
| Tan δ & hot-set 试验 | IEC 60502-2 / DIN VDE 0250-813 | 每生产批次 |
| Impulse 电压 withstand | 170 kV BIL lightning impulse 试验 | 型式认可 |
标识与供货
护套印字
常见问题
未涵盖您的问题?欢迎发送图纸或工况,工程师将在 2 个工作小时内回复。
获取报价
所选规格与工况将一起带入下方询价表单。